Resumen del manual


To define a new Hot Key, complete the following steps: 1. Enter the key combination to define a new Hot Key in the Enter Key textbox. 2. The Note displays important information indicating Hot Keys that should not be used. Product Reference Guide Falcon® Desktop Utility for Windows® CE Figure B-5. Add a New Hot Key Table B-6. Adding a New Hot Key Dialog Command Description Enter Key Enter the desired key combination in this text box to define a Hot Key. OK Select/tap OK to add the specified Hot Key. X Select/tap X to cancel the specified Hot Key. Make sure you do not attempt to add a Hot Key that is already defined. 3. Select/tap OK to save the New Hot Key. If you select/tap X, the key will not be saved. It is possible for the keyboard wedge to activate assigned Hot Keys using alphanumeric characters. Bar codes containing characters associated with assigned Hot Keys will trigger the action or application assigned to that Hot Key. Internet Explorer Configuration Tap the IE (Internet Explorer) tab to access the IE Configuration option. Use the IE Error Redirection option to provide customized recovery from common IE errors. When an error occurs, the browser can redirect access to a specified error page with instructions on how to recover from the problem. Falcon® 4400 Series with Windows® CE Falcon Desktop Utility Figure B-6. IE Configuration Tab / IE Window Features IE Address Bar IE Tool Bar IE Menu Bar IE Status Bar Table B-7. IE Tab Fields Command Description Error Type The Error Types pull-down list displays available IE Error Types: (400) Invalid Syntax, (403) Request Forbidden, (404) Object Not Found, (406) No Response Format, (410) Page Doesn't Exist, (500) Internal Server Error, (501) Server Can't Do That, Generic Error, Server Is Busy, Couldn't Find Server, URL Syntax Error, Request Cancelled, Not Available Offline Error Page Edit this textbox to associate a website or html file with the specified error. Assign as Default Select/tap to set a specified error page as the default. A confirmation dialog opens to ask if the default error page applies to all errors. Browse Select/tap to browse for files. Show Address Bar Select/tap this check box to show the IE address bar. Show Tool Bar Select/tap this check box to show the IE toolbar. Show Status Bar Select/tap this check box to show the IE status bar. Show Menu Bar Select/tap this check box to show the IE menu bar. Product Reference Guide Falcon® Desktop Utility for Windows® CE Internet Options Tap Internet Options on the IE tab to open the Windows CE Internet Options control panel. Customize these settings as necessary. The Internet Options control panel applet is part of the Microsoft® Windows® CE operating system. For more information on the Windows CE operating system, please refer to the Microsoft website at The FDU allows you to cancel prior to applying your changes. However, any settings modified in the Internet Options control panel applet through the FDU inter face will be applied even if you later cancel the your modifications in the FDU. CAUTION Modifying Windows Controls Select/tap the Win (Windows Controls) tab to access the Windows Controls option. Use Windows controls to allow or restrict access to Windows system functions. You can disable normal Windows functions such as the desktop and taskbar, leaving nothing but a blank workspace. This allows applications to be run on the full screen and prevents users from accidental or unauthorized use of the taskbar, Internet Explorer, and any other resident applications. Figure B-7. Windows CE Desktop and Win Tab WinCE Desktop Start Menu Taskbar Falcon® 4400 Series with Windows® CE Application Selector Table B-8. Win Tab Fields Command Description Show Taskbar Select/tap Show Taskbar to specify that the taskbar is shown or hidden. Taskbar Enabled Select/tap Taskbar Enabled to specify whether the taskbar is accessible. This option is only available when the Show Taskbar is checked. Start Menu Enabled Select/tap Start Menu Enabled to specify whether the Start menu is accessible or not. This option is only available when both Show Taskbar and Task Bar Enabled are checked. Windows CE Desktop Enabled Select/tap Windows CE Desktop Enabled to specify that the desktop icons are accessible or not. Application Selector Use the Application Selector (AppSelect Tab) function to edit, add, or delete applications for the application selector. Figure B-8. AppSelect Tab Product Reference Guide Falcon® Desktop Utility for Windows® CE Table B-9. AppSelect Tab Fields Command Description Enable Application Selector Select/tap Enable Application Selector to enable/disable the application selector. When this is enabled, the Application Selector replaces the desktop and allows only authorized use of applications. Authorized Applications This is a list of applications that the user may access. New Select/tap New to create a new application entry. Edit Select/tap Edit to edit the selected entry. D...

Otros modelos de este manual:
escáner / copiadora / impresora multifunción - 4410 (4.78 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría