Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Cissell, modelo HF150

Fabricar: Cissell
Tamaño del archivo: 1.7 mb
Nombre del archivo: 0a28489c-07ce-455f-bdc1-16bc50dc1f29.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Ventilation soap dispenser B. Liquid soap connetions C. Hard water connections 3/4" D. Warm water connections 3/4" E. Soft water connections 3/4" F. Connections clamps G.Electrical connections H.Emergency button I. Ventilation tub K. Drain valve L. Steam connections Dimensions 2 HF150 - 185 720 35 1265.5 1386 155.5 251 346 94 173 165 105 1309.5 F L K A C B D E G I 1500 738 900 81 81 1527.5 645 HF234 = 939.5 HF234 = 926 HF234 = 830 70 35 60 35 240 H Dimensions 2 HF234 A. Ventilation soap dispenser B. Liquid soap connetions C. Hard water connections 3/4" D. Warm water connections 3/4" E. Soft water connections 3/4" F. Connections clamps G.Electrical connections H.Emergency button I. Ventilation tub K. Drain valve L. Steam connections HF234 HF150-185 The machine must be placed on a fl at, solid surface (metal base, concrete or solid ground). It is recommended that the machine be anchored on the provided places (A) in the base, especially in case of a plinth (see Dimensions 2). The machine must be placed entirely level. For easy maintenance it is recommended to keep a minimal distance of 600 mm between the wall and the back of the machine. If several machines are placed next to each another, there should be a minimal distance of 30 mm between each machine. To prevent damage during transportation, the machine has been equipped with four red transport brackets to eliminate every possible movement of the tub. After the machine has been placed level, take off the service- and the back panel to remove these transport brackets. Important The machine must never be activated before removing these transport brackets. Removal of the transport safety The machine is delivered with hoses with 3/4" connections. These hoses fi t the water inlet valves of the machine and the main water inlet taps. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 0,5 and 10 kg/cm. (7 and 145 psi). If the pressure is too low, the cycle time will increase considerably. In case of boiler fed machines, a minimum of hot water of 90°C should be available: For the HF150: 94 l. HF185: 115 l. HF234: 150 l. Water connection Installation and connection 3 Ground 3 Remove the cover plate at the back of the machine. (See dimensions (E)). Connect the power cable to the connectors. 220V 3AC 220V 3 phase (3AC) should be connected to the connectors “L1,L2,L3”. The green/yellow grounding clamp has to be connected to the grounding wire “PE”. 380 V 3AC + N 380 V 3 phase (3AC + N) has to be connected to the connectors “L1,L2,L3”, the blue neutral to the “N” connector. The green/yellow grounding clamp has to be connected to the grounding wire “PE”. After connection, check the spin direction. The cylinder must spin in the direction of the arrow, showed on the sticker on the door window (clockwise). A wrong spin direction can damage the motor, and can also cause water to spurt from the soap dispenser. Electrical Connection The machine is equipped with a drain valve (HF150-185) with 2" outer diameter (50mm) (HF234) 3" outer diameter (80 mm). This drain valve should be connected to the drain by means of the drain elbow which is delivered with the machine. The diameter of the main drain should be adapted to the water fl ow and the number of machines. It should be suffi cient to handle at least 160L/min. per machine. It is necessary to connect the main drain at least on one side to an open air-brake to allow ventilation. When the main drain has not been suffi ciently deodorized, every machine should be installed seperately with a deodorizer. Water drain machine with steam heating or boiler fed machines without additional electrical heating Power of the breaker plugs: 220V 3AC 380V 3AC + N 9kw 25A 16A 12 kW 40 A 20 A 15 kW 50 A 25 A 18 kW 50 A 32 A 21 kW ---- 40 A 24 kW ---- 40 A machine with electrical heating 220V 3AC 380V 3AC + N 16 A 16 A 3 With an external tension 24V DC Electrical connection of the liquid soap pumps On machines equipped with a liquid soap connection, connect the wires directly on the print board next to the ground wire connection (option). Connect as indicated on the wiring diagram. The two connectors on the right give a tension of 220V ~ (max. 4A) which can be applied to drive 220V ~ soap pumps. If more than 4A is required, an external tension will have to be used. 6 connections have been provided, of which one (S6) can be used to drive a waterproofi ng pump (e.g. for rain coats, etc.). The 220V can be transformed to other values to drive other type soap pumps. Example: pumps 24V ~. Also, pumps with different operating tension can be combined. Example: 5 pumps 220V ~ and 1 pump 24V ~. The liquid soap connection consists of 8 connections for liquid soap (SI….S). The central opening is used for ventilation. Liquid soap connection (option) Connection of the liquid soap hoses 3 A A Connection of a central operating panel for coinmachines (option) At the backside abov...

Otros modelos de este manual:
Lavadoras - HF185 (1.7 mb)
Lavadoras - HF234 (1.7 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría