Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario Equator, modelo EZ 3612 CEE

Fabricar: Equator
Tamaño del archivo: 2.38 mb
Nombre del archivo: 96e6d12a-0aa3-5374-09cf-48fa9c754b6f.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


3", enough time for the main PCB to accept the start and begin a new programme. wash empty ON Fault not signalled (test performed on Selector Feed of HW position search) (N.B. the SW does not foresee the signalling of the fault F06 if the TRIAC is not enabled by the microprocessor)? BACO wash full ON wash dry empty ON Selector TRIAC open Standby empty OFF Fault not signalled Standby empty ON wash empty ON Fault F06 signalled. Test conditions: tests performed on Selector Feed of HW position search wash full ON wash dry empty ON Door lock TRIAC short-circuited Standby empty OFF Fault not signalled Standby empty ON wash empty ON The door lock remains powered in all the selector's positions wash full ON wash dry empty ON FAULTS SITUATION ON THE MAIN PCB COMPONENTS Type of Fault Main PCB Status Press. Status Door lock Satus Appliance behaviour under fault conditions Door lock TRIAC open Standby empty OFF Fault not signalled Standby empty ON wash empty ON The appliance cannot be started wash full ON wash dry empty ON Motor TRIAC short-circuited Standby empty OFF Fault not signalled Standby empty ON Fault F01 signalled (at hight speed 1150 rpm increase in the same up to 1380 and fault signalled at the end of the cycle) wash empty ON wash full ON wash dry empty ON Motor TRIAC open Standby empty OFF Fault not signalled Standby empty ON wash empty ON Fault F02 signalled wash full ON wash dry empty ON TYPE OF FAULTS ON THE MAIN PCB COMPONENTS Type of Fault Main PCB Status Press. Status Door lock Satus Appliance behaviour under fault conditions Dry heating element TRIAC short-circuited Standby empty OFF Fault not signalled Standby empty ON Fault not signalled and dry heating of the RA. Test to be performed with the new protection cycle wash empty ON wash full ON wash dry empty ON Dry heating element TRIAC open Standby empty OFF Fault not signalled Standby empty ON wash empty ON wash full ON wash dry empty ON Fault not signalled. In this condition the contact of the RA is not protected be the TRIAC during the opening and closing phases. (Simulation of conduction of the TRIAC one way only) Type of Fault Main PCB Status Press. Status Door lock Satus Appliance behaviour under fault conditions Selector power supply by half a wave Standby empty OFF Fault not signalled Standby empty ON wash empty ON Test conditions: where the program requires the selector feed or the search for a starting position. Fault F06 signalled. N.B. The pulsating voltage is not enough to make the selector turn wash full ON wash dry empty ON Selector valve power supply by half a wave Standby empty OFF Fault not signalled Standby empty ON wash empty ON The pulsating voltage at the ends of the valve is enough to enable it even with the minimum mains voltage. The fault is protected by the overflow contact that enables the P.S. on a S.W. wash empty ON wash dry empty ON Fault F05 signalled after the pressure switch on full is reached Door lock power supply by half a wave Standby empty OFF The pulsating voltage at the ends of th PTC is enough to enable the contact even at the minimum mains voltage and the door lock remains enabled in all the positions and under all conditions. Standby empty ON wash empty ON wash full ON wash dry empty ON Dry heating element power supply by a half wave Standby empty OFF Fault not signalled Standby empty ON Fault F13 signalled if the door lock contact release time allows the safety temperature to be reached wash empty ON Fault F13 signalled generated by the continuous presence of the pulsaing voltage at the ends of the RA that raise the temperature and reach the safety limit value wash full ON wash dry empty ON The fault is not signalled because the SW control and the heating element ventilation do not allow the temperature to reach the safety value Wash Motor powered by half a wave Standby empty OFF Fault not signalled Standby empty ON Fault F04 signalled wash empty ON wash full ON wash dry empty ON FAULTS SITUATION ON THE APPLIANCE COMPONENTS Types of Fault Main PCB Status Press. Status Door lock Satus Appliance behaviour under fault conditions Blower circuit 100% obstructed wash dry empty ON The temperature rises until the limit valve of the drying sensor recalls fault F13 (NTC limit value 125 degrees C Blower circuit 50% obstructed wash dry empty ON Severe condition: Temperature set for the wash and dry sensor reached for the execution of the macro. In this condition the temperature inside the tub fails to fails to rise and consequently prevents the cycle from proceeding. Broken soleoid valve Standby empty OFF Once the pressure switch is on full level is reached, the SW foresees the enabling of the door lock, which allows the overflow contact to enable the drain pump on a SW and HW level. Standby empty ON Condition protected by the overflow that enables the drain...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría