Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario GE, modelo GE Spacemaker DSKS433A

Fabricar: GE
Tamaño del archivo: 52.3 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


30 ft. 22 ft. kitchen exhaust, since the combination of lint and grease could create a fire hazard. Spacemaker ® Model WSM2700T Spacemaker ® Models 1 2 3 0 46 ft. 34 ft. 32 ft. 43 ft. 36 ft. 28 ft. 18 ft. 36 ft. 22 ft. 16 ft. 10 ft. 30 ft. 14 ft. 10 ft. 5 ft. 24 ft. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12” above the ground or any other obstruction with the opening pointed down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4” opening dampered wall cap. WSM2420T WSM2480T 1 2 33 ft. 23 ft. 26 ft. 16 ft. 24 ft. 16 ft. 18 ft. 10 ft. Special Installation Requirements Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. A For more information on venting kits and accessories, please • The dryer MUST be exhausted to the outside. call 1-800-GE-CARES. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0” either side 3” front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. • No other fuel-burning appliance shall be installed in the same closet with the dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223. Minimum Clearances other than Alcove or Closet Installation: •Minimum clearances to combustible surfaces For answers to your Monogram,® 0” both sides GE Profile Performance Series,™ 3” rear GE Profile™ or GE appliance questions, call GE Answer Center® service, 800.626.2000. Specification Created 2/00 Listed by Underwriters Laboratories Specification Created 2/00 GE Appliances WSLS1100A/DSKS433A–GE Spacemaker® Stationary Washer and Dryer With Stack Rack Features and Benefits •Washer Features: – Extra-Large Capacity – 1 Wash/Spin Speed – 4 Wash/Rinse Temperatures – 4 Water Levels – 10 Cycles: Regular (Heavy Soil, Medium Soil), Permanent Press (Medium Soil, Light Soil), Delicates and Spin Only – One Touch Load Sensing – Automatic Cool Down – Fabric Softener, Bleach and Automatic Detergent Dispenser – 2 Removable Lint Filters – Quiet Pump – Stainless Steel Basket – Stationary Model • Dryer Features: – Compact Capacity – Automatic Dry Control – 3 Drying Cycles: Automatic Permanent Press - Delicates, Auto Regular and Timed Dry (Up to 140 Minutes) – 4 Heat Selections: Regular (High Heat), Permanent Press (Mediu...

Otros modelos de este manual:
Lavadoras - GE Spacemaker DSKP233EW (52.3 kb)
Lavadoras - GE Spacemaker DSKS433EAAA (52.3 kb)
Lavadoras - GE Spacemaker DSKS433EAWW (52.3 kb)
Lavadoras - GE Spacemaker DSKS433EW (52.3 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría