To reset the count, press the CLEAR button and “00” will be displayed. If the coin count is greater than “999,” the display will flash “999.” Setting DIP switch #7 to the OFF position will return the display to “PAy.” © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400001 15 Operating Instructions DMP OPL Models DO Control Suffix Description of the OPL Control Panel Refer to Figure 7. TMB1956N 1 START. Starts or resumes the current program or cycle. 2 STOP. Temporarily halts the current cycle or cancels the current program. 3 Up/Down Arrows. Increases or decreases the value in the display. In conjunction with the DISPLAY button, these buttons are used to adjust the drying time, cooling time, temperature, clockwise time, dwell time, counter-clockwise time, and minutes per coin (Coin only). 4 Display. Displays the drying time, cooling time, drying temperature and diagnostic codes. 5 User Program LEDs. Illumination shows which user program is currently being displayed. 6 Program Select. This button toggles through the five user programmable programs. Holding this button will save a program, as indicated in Programming. 7 Display Select. Toggles the display between the drying time, cooling time, and temperature settings. Pressing the Display button for 3 seconds allows the user to display the drying cycle temperature. 8 DRYING LED. Illuminated when in the drying cycle. 9 COOLING LED. Illuminated when in the cooling cycle, or when the display is currently showing the time for the cooling cycle. 10 TEMPERATURE LED. Illuminated when the display is showing the temperature setting. 1 2 3 4 5 DRYING COOLING TEMPERATURE REV START STOP (CANCEL) 1 2 3 4 6 5 5 8 9 10 7 Figure 7 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions DMP OPL Features DIP Switch Settings The DMP has an 8 position DIP switch bank that is accessible from the back of the control board. By switching these DIP switches, it is possible for the operator to customize the display and some of the operating features of the tumbler. Dip Switch Funtion 1 Tumbler Type ON - Coin OFF - OPL 2 Temperature Units ON -C OFF* - F 3 Local or Remote Reversing ON* - Local Reversing OFF - Remote Reversing 4 Empty ON* 5 Empty ON* 6 Buzzer Timer ON - Continuous OFF - 5 Sec 7 OPL Models - Safety Tumble Dip Switch #1 #7 OFF ON Safety Tumble OFF OFF No Safety Tumble Coin Models - Coin Count/Pay Dip Switch #1 #7 ON ON Coin Count ON OFF Pay 8 Programming ON - Enable OFF* - Disable * Factory default setting Table 2 DIP Switch Functions Explained 1. Tumbler Type: This DIP switch selects the type of tumbler, i.e., OPL or Coin. 2. Temperature Units: Selects .F or .C for the temperature display. Factory setting is for .F. 3. Local/Remote Reversing: Preset at the factory; usually for local reversing. Remote reversing for use with Reversing Timer Board only. 4. Empty: Preset at the factory; always ON. 5. Empty: Preset at the factory; always ON. 6. Buzzer Timer: This DIP switch determines the length of time that the end of cycle buzzer will remain on. “OFF” indicates that the buzzer will sound for 5 seconds when the drying cycle is completed. “ON” indicates that the buzzer will sound continuously until the STOP button is pressed or the loading door is opened. 7. Safety Tumble (OPL) or Coin count/Pay (Coin): If DIP switch #1 is set for OPL, then DIP switch #7 in the ON position enables the safety tumble. If DIP switch #1 is set for Coin, then DIP switch #7 in the ON position enables the display of the coin count. DIP switch #7 in the OFF position enables the display of “PAy,” to indicate that coins are needed to run the tumbler. 8. Programming: This switch enables or disables the programming feature and should normally be in the OFF position. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400001 17 Operating Instructions Programming Rotation Sensor 1. Set DIP switch #8 to the ON position. 2. Select the desired program number to change. The LED should be flashing. 3. Select DRY TIME. Set the time with the Up/ Down arrows. 4. Select COOL TIME. Set the time with the Up/ Down arrows. 5. Select TEMPERATURE. Set the temperature with the Up/Down arrows. 6. Press and hold the Program Select button about 3 seconds until the LED stops flashing. The selected program number is now programmed. If the Program button is pressed for less than 3 seconds, the controller will cancel the program and display the next program’s settings. If not programmed correctly, the display will flash “E2F” for 4 seconds, and the default settings will be used. Follow steps 4 through 7 to reprogram any program number. When finished, set DIP switch #8 to OFF. The programs are now stored. 7. During the Program Mode, if the Up/Down arrows or Display button is not pressed within 10 seconds, the default program settings will be used. 8. Temporary Reprogramming of Current Programs (OPL ONLY) 9. The Drying Time, Cooling Time and Temperature of ...

Otros modelos de este manual:
Lavadoras - 30 Pound Capacity (639.47 kb)
Lavadoras - 25 Pound Capacity (639.47 kb)
Lavadoras - 35 Pound Capacity (639.47 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría