Close supervision of children is necessary when the appliance is used near children. FOR YOUR SAFETY: A WARNING • Use only rigid metal or flexible metal 4-in. diameter ductwork for exhausting to the outdoors. Never use plastic or other combustible, easy-to-puncture ductwork. • This appliance must be properly grounded and installed as described in these instructions. • Do not install or store appliance in an area where it will be exposed to water and/or weather • Install the dryer where the temperature is above 50°F for satisfactory operation of the dryer control system. NOTE: Installation and service of this dryer requires basic mechanical and electrical skills. It is your responsibility to contact a qualified installer to make the electrical connections. TOOLS YOU WILL NEED FLAT BLADE Si 'ER PHILLIPS SCREWDRIVER LEVEL MATERIALS YOU WILL NEED 4" DIA. METAL DUCT (RECOMMENDED) 4“ DUCT CLAMPS (2) OR 4“ SPRING CLAMPS (2) 4" DIA. FLEXIBLE METAL DUCT (IF NEEDED) 4" DIA. METAL ELBOW EXHAUST HOOD SAFETY GLASSES DUCT TAPE GLOVES 3/4- STRAIN RELIEF UL RECOGNIZED DRYER POWER CORD KIT (NOT PROVIDED WITH DRYER) UL RATED 120/240V, 30A WITH 3 OR 4 PRONGS. IDENTIFY THE PLUG TYPE AS PER THE HOUSE RECEPTACLE BEFORE PURCHASING LINE CORD. Step 1 Prepare the Area and Exhaust for Installation of New Dryer (see section 1). Step 2 Check and Ensure the Existing External Exhaust is Clean (see section 1) and Meets Attached Installation Specifications (see section 3). Step 3 Remove the Foam Shipping Pads (see section 1). Step 4 Move the Dryer to the Desired Location. Step 5 Connect the Power Supply (see section 2). Step 6 Connect the External Exhaust (see section 4). Step 7 Level Your Dryer (see section 5). Step 8 Check the Operation of the Power Supply and Venting. Step 9 Place the Owners Manual and the Installation Instructions in a Location Where They Will Be Noticed By the Owner. For Alcove or Closet Installation, see section 6. For Bathroom or Bedroom Installation, see section 7. For Mobile or Manufactured Home see, section 8. For side or bottom exhaust, see section 9. Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for installation and service. m ELECTRICAL CONNECTION INFORMATION A WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK AND PERSONAL INJURY: • DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE. Dryer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70. ELECTRICAL REQUIREMENTS This dryer must be connected to an individual branch circuit, protected by the required time-delay fuses or circuit breakers. A four or three-wire, single phase, 120/240V or 120/208V, 60Hz, 30 amp circuit is required. If the electric supply does not meet the above specifications, then call a licensed electrician. GROUNDING INSTRUCTIONS This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal on the appliance. CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR MOBILE HOME INSTALLATION) NOTES: Since January 1,1996, the National Electric code requires that the new constructions utilize a 4-wire connection to an electric dryer ^WARNING :Only a 4-conductor cord shall be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for the new branch-circuit installations, mobile homes, recreational vehicles, and areas where local codes prohibit grounding through the neutral conduction. REMOVE GROUND STRAP AND DISCARD. KEEP GREEN GROUND SCREW [^7 WIRE RELOCATE GREEN GROUND SCREW HERE GREEN OR .YELLOW WIRE HOT WIRE 3/4", UL RECOGNIZED STRAIN RELIEF COVER 4 #10 AWG MINIMUM COPPER CONDUCTORS OR 120/240V 30A POWER SUPPLY CORD KIT MARKED FOR USE WITH DRYERS & PROVIDED WITH CLOSED LOOP OR SPADE TERMINALS WITH UPTURNED ENDS (NOT SUPPLIED). INTERNAL DUCT OPENING CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FREELY TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING THEM AWAY FROM THE DRYER LEGS. BE SURE TO REMOVE ALL OF THE FOAM PIECES AROUND THE LEGS. Installation Instructions 1. Turn off the circuit breaker (s) (30 amp) or remove the dryer’s circuit fuse at the electrical box. 2. Be sure the dryer cord is unplugged from the wall receptacle. 3. Remove the power cord cover located at the lower back. 4. Remove and discard ground strap. Keep the green ground screw for step 7. 5. Install 3/4 in. UL recognized strain relief to power cord entry hole. Bring power cord t...
Otros modelos de este manual:Lavadoras - DMCD330EHWC (1.06 mb)