Iniciar sesión:
Votos - 1, Puntuación media: 3 ( )

Manual de usuario Central Pneumatic Air Compressor, modelo PLASTIC CAP STAPLER 99637

Fabricar: Central Pneumatic Air Compressor
Tamaño del archivo: 595.67 kb
Nombre del archivo: 99637.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles. (California Health & Safety Code § 25249.5, et seq.) WARNING: The brass components of this product contain lead, a chemical known to the State of California to cause birth defects (or other reproductive harm). (California Health & Safety code § 25249.5, et seq.) 3. Only use with accessories rated to handle the forces exerted by this Stapler during operation. Other accessories not designed for the forces generated may break and forcefully launch pieces. 4. Attach all accessories properly to the Stapler before connecting the air supply. A loose accessory may detach or break during operation. 5. Obey the manual for the air compressor used to power this Stapler. 6. Install an in-line shutoff valve to allow immediate control over the air supply in an emergency, even if a hose is ruptured. 7. Use this Stapler with both hands only. Using tools with only one hand can result in loss of control. Vibration Precautions This Stapler vibrates during use. Repeated or long-term exposure to vibration may cause temporary or permanent physical injury, particularly to the hands, arms and shoulders. To reduce the risk of vibration-related injury: 1. Anyone using vibrating tools regularly or for an extended period should first be examined by a doctor and then have regular medical check- ups to ensure medical problems are not being caused or worsened from use. Pregnant women or people who have impaired blood circulation to the hand, past hand injuries, nervous system disorders, diabetes, or Raynaud’s Disease should not use this tool. If you feel any medical or physical symptoms related to vibration (such as tingling, numbness, and white or blue fingers), seek medical advice as soon as possible. 2. Do not smoke during use. Nicotine reduces the blood supply to the hands and fingers, increasing the risk of vibration-related injury. 3. Wear suitable gloves to reduce the vibration effects on the user. 4. Use tools with the lowest vibration when there is a choice between different processes. 5. Include vibration-free periods each day of work. 6. Grip tool as lightly as possible (while still keeping safe control of it). Let the Stapler do the work. 7. To reduce vibration, maintain the Stapler as explained in this manual. If abnormal vibration occurs, stop immediately. SAVE THESE INSTRUCTIONS. PRODUCT SPECIFICATIONS Air Pressure Range 70-90 PSI Air Hose Requirement 3/8” I.D. Air Inlet 1/4” -18 NPT Air Consumption 6.0 CFM Fastener Type Staples with Plastic Caps Staple Length 3/8” to 1-1/4” Staple Crown Size 3/8” Crown Staple Gauge 18 Gauge Plastic Cap Diameter 1” O.D. Plastic Cap Capacity 100 Plastic Caps Magazine Capacity Strip of 100 Staples Firing Method Intermittent Single Fire Safety Trigger Single Sequential Safety Trip Mechanism Adjustable Drive Depth Rotational Knob at Left Side of Stapler PRODUCT FEATURES FIGURE ADRIVE DEPTHADJUSTER(47) MAGAZINELATCH(63) TRIGGER(39) BOTTOM PLATE(95) CANISTERLATCH(104) PLASTICCAPCANISTER(105) EXHAUSTCAP(1) MAGAZINESA & B(67, 73) TOOL SET UP/ASSEMBLY Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual. Unpacking When unpacking, check to make sure that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at the number shown throughout the manual as soon as possible. • This air tool may be shipped with a protective cap covering the Air Plug (57). Remove this cap before set up. Air Supply TO PREVENT EXPLOSION: Use only clean, dry, regulated, compressed air to power this tool. Do not use oxygen, carbon dioxide, combustible gases, or any other bottled gas as a power source for this tool. REV 08k 1. Incorporate a filter, regulator, oiler and shut off valve for best service, as shown in the diagram above. An in- line shutoff valve is an important safety device because it can immediately shut-off air flow in case of tool or hose failure. Note: If an automatic oiler system is not used, add a few drops of Pneumatic Tool Oil to the airline connection before operation. Add a few more drops after each hour of continual use. 2. Attach an air hose to the compressor’s air outlet. Connect the air hose to the air inlet of the tool. Other components, such as a connector and quick coupler, will make operation more efficient, but are not required. WARNING! TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Do not install a female quick coupler on the tool. Such a coupler contains an air valve that will allow the air tool to retain pressure and operate accidentally after the air supply is disconnected. Note: Air ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría