in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. • No other fuel-burning appliance shall be installed in the same closet with the dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223. Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces 0” both sides 3” rear Specification Created 7/99 For complete information, see installationinstructions packed with your dryer. Important Note: GE Kit Number WE14X70 needed when converting rear Ducting Materials: For best performance, this dryer should be vented with 4” diameter duct cannot be used, then “flexible all metal” venting can be used, duct length. Exhaust Length Calculation: 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated in the table. The maximum length for flexible ducts are less than for rigid duct. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow. Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12” above the ground or any other obstruction with the opening pointed Down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4” opening dampered wall cap. Listed by Underwriters Laboratories R NVL333GYWW - Hotpoint Features and Benefits • Large Capacity (5.7 Cubic Feet) • Automatic Dry Control • 3 Heat Selections (Timer) • 3 Cycle Selections: –Automatic Cottons –Automatic Permanent Press –Timed Dry (70 Minute) with Air Fluff • Removable Up-Front Lint Filter • Painted Steel Drum Interior • Reverse-A-Door • 100% Front Serviceable • Model NVL333EYWW–White on white (Electric) • Model NVL333EYAA–Almond on almond (Electric) • Model NVL333GYWW–White on white (Gas) • Model NVL333GYAA–Alm...

Otros modelos de este manual:
Secadoras - NVL333EYAA (38.86 kb)
Secadoras - NVL333GYAA (38.86 kb)
Secadoras - NVL333GYWW (38.86 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría