Circuit Requirements: An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required. Electric Dryer Rating: 208/240V, 3-wire, 5600W, 60Hz, 30 Amp Installation Information: For complete information, see installation instructions packed with product for current dimensional data. R Listed by Underwriters Laboratories Specification Revised 8/99 NVLR333EVWW—Hotpoint Dryer Exhausting Information—Use For complete information, see installationinstructions packed with your dryer. 4 B A 2-1/2 Domestic Dryer Models Super & Extra-Large Capacity Models All Electric Dryers Super & Extra-Large Capacity Models All Gas Dryers Large Capacity Electric and Gas Dryers Number of 90° Turns 0 1 2 3 4 0 1 2 3 0 1 2 3 4 Specification Revised 8/99 Best Performance Maximum Length of 4" Dia. Rigid Metal Duct Exhaust Hood Type Cat. No. WX8X59 (Preferred) A 4" Opening 90 ft. 60 ft. 45 ft. 35 ft. 25 ft. 45 ft. 35 ft. 25 ft. 15 ft. 60 ft. 52 ft. 44 ft. 32 ft. 28 ft. B 2-1/2" Opening 60 ft. 45 ft. 35 ft. 25 ft. 15 ft. 30 ft. 20 ft. 10 ft. — 48 ft. 40 ft. 32 ft. 24 ft. 16 ft. Important Note: GE Kit Number WE14X70 needed when converting rear exhaust Maximum Length of 4" Ducting Materials: Dia. Flexible Metal Duct For best performance, this dryer should be vented with 4” diameter be Exhaust Hood Type Cat. No. WX8X59 (Preferred) A 4" Opening 55 ft. 40 ft. 30 ft. 20 ft. 15 ft. 30 ft. 20 ft. 10 ft. — 30 ft. 22 ft. 14 ft. — — used, then “flexible all metal” venting can be used, but it will reduce Exhaust Length Calculation: B 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2-1/2" Opening 2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated 45 ft. for flexible ducts are less than for rigid duct. 30 ft. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° 20 ft. 15 ft. should be treated as a 90° elbow. 10 ft. Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being 15 ft. blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside. 10 ft. — Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an — attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate 18 ft. common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire 14 ft. 10 ft. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap — ft. located at least 12” above the ground or any other obstruction with the opening pointed Down. — ft. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4” opening dampered Special Installation Requirements Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0” either side 3” front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. • No other fuel-burning appliance shall be installed in the same closet with the dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223. R Listed by Minimum Clearances other than Alcove or Closet Installation: Underwriters Laboratories 0” both sides 3” rear • Minimum clearances to combustible surfaces NVLR333EVWW—Hotpoint Features and Benefits • Large Capacity (5.4 Cubic Feet) • Automatic Dry Control • 3 Cycle Selections: Cottons, Permanent Press, 70 Dry (No-Heat) • 3 Heat Selections • Up-Front Lint Filter • Porcelain Drum Interior • Front Serviceable • Model NVLR333EVWW–White on White (Electric) • Model NVLR333EVAA–Almond on Almond (Electric) • Model NVLR333GVWW–White on White (Gas) • Model NVLR333GVAA–Almond on Almond (Gas) Specification Revised 8/99 ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría