Fabricar: Cissell
Tamaño del archivo: 651.11 kb
Nombre del archivo: 8796c4c1-cbd8-41f7-bd04-ec783f2e8939.pdf
|
Resumen del manual
The currents listed are rated for system voltage ranges of 110 – 220 and 220 – 240. ** Rated Amperes are to be used to determine incoming conductor size and short-circuit protection. Rated amperes are figured in accordance with the 1981 NATIONAL ELECTRIC CODE, Sections 430-22 and 430-24. Table 2 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 Installation Overall Dimensions and Connecting Data SCR97N OPENOPENCLOSECLOSECLOSECLOSESTEAM INLETSTEAM INLET 36-7/8 in. (93.7 cm) HEAD OPEN 38 in. (96.5 cm) 1-1/2 in. TYP (3.8 cm) 34 in. (86.4 cm) 23 in. (58.5 cm) 53 in. (134.6 cm) HEAD OPEN HEIGHT 16 in. (40.6 cm) 20 in. (50.8 cm) 1 in. TYP (2.5 cm) 2 in. (5.1 cm) Figure 5 AJ1031 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 13 Installation SCR98N 1-1/2 in. (3.8 cm) 21 3 4, 5 3-3/4 in. (9.5 cm) 4-3/4 in. (12 cm) 1-1/2 in. (3.8 cm) 5-1/2 in. (14 cm) 1-1/8 in. (2.9 cm) 18-1/4 in. (46.4 cm) 1-1/2 in. (3.8 cm) Figure 6 Item Description Above Flat Floor Connection inches cm 1 Electrical Connection (for presses with timer ONLY) 12 30.5 Refer to Table 2 2 Air Inlet 11 28 1/4 NPT-F 3 Steam Inlet 21.63 55.0 1/2 NPT-F 4 Buck Steam Outlet 21.25 54.0 1/2 NPT-F 5 Head Steam Outlet 23.25 59.0 1/2 NPT-F Table 3 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 Installation Dimensions of Bucks Without Padding SCR558N 90° 8-1/4 in. (21 cm) 6-1/2 in. (16.5 cm) 20-1/2 in. (52 cm) 13 in. (33 cm) 30-1/2 in. (77.4 cm) 13-3/4 in. (34.9 cm) 10-3/4 in. (27.3 cm) LDCC COLLAR, CUFF & YOKE PRESS LDBB BOSOM & BODY PRESS Figure 7 AJ1031 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation Required Materials NOTE: Applicable codes, ordinances, specifications and/or other governing data related to installation must be complied with. The materials listed in Table 4 MAY or MAY NOT conform to these requirements. Quantity Description Source 1 Models with timer ONLY. Lockout type fused disconnect switch suitable for electric service connected to press (refer to wiring schematic in control box). Not required if circuit breaker is used. Local As required Models with timer ONLY. Wire of suitable size, type and length to connect electric service to press (refer to wiring schematic in control box). Local As required Models with timer ONLY. Flexible conduit and connections to encase wires and make connections (refer to wiring schematic in control box). Local 2 Steam trap and check valve, or combination steam trap/check valve sized for buck and head steam return lines and steam consumption. Local 3 Ball shut-off valves sized for steam supply and return lines. Local 1 Ball shut-off valve sized for air supply line. Local 4 Anchor bolts. Local As required Pipe, couplings, unions, flanges, etc., to connect steam supply and return lines and air supply line to press. Wall thickness of pipe and tubing must be in compliance with recommendations by compressor and boiler manufacturers and local code (refer to sections on Connecting Steam Supply and Returns and Connecting Air Supply). Local Table 4 Receiving Inspection Press is shipped assembled and enclosed in a wood slat crate. Upon delivery, inspect crate and contents for shipping damage. If crate or cover is damaged, or signs of possible damage are evident, have carrier note condition on shipping papers BEFORE shipping receipt is signed, or advise carrier of condition when discovered. Remove protective cover and check items received against items listed on packing list. If any item is damaged or missing, a written claim should be filed with carrier as soon as possible. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 Installation Location Requirements NOTE: If a forklift is used to move press, exercise care that forklift arms are inserted under frame and DO NOT CONTACT ANY OPERATING MECHANISM. Moving press to installation location while still attached to skid is recommended. However, press can be removed from skid before moving. Removing Press from Skid Unscrew four shipping screws from attaching holes. Using a forklift, lift press and remove skid. Press should be located in an area that provides a minimum of 24 inches (61 cm) between press and any structure. NOTE: Above dimensions are considered MINIMUM working and maintenance dimensions and SHOULD BE INCREASED if possible. Space between front of table and closest structure should be determined by work requirements, but in no case should be less than 30 inches (76.2 cm). Foundation Requirements Install press on a solid, level floor such as concrete. NOTE: Installation on a wooden floor can cause machine to shift, which WILL result in MISALIGNMENT of heads and bucks and DAMAGE to both press and garments. Floor should be capable of supporting 125 pounds per square foot (56.7 kg). Remove all floor covering material (tile, wood, carpeting, etc.) from press mounting area. Uncrating Remove front cover from press and use a hammer to knock out ship...
Otros modelos de este manual:Secadoras - LDCC (651.11 kb)