indicator is off, then the fault is in the phase 5 OPL microprocessor controller itself. If the motor is not operating and the "MOTOR" output indicator is on, then the problem is elsewhere (i.e., external of the microprocessor controller). "FWD" Output L.E.D. Indicator — a. If the dryer is started and the blower motor is operating but the drive (basket (tumbler) motor is not, yet the Phase 5 OPL microprocessor controller display "FORWARD" indicator dot is on, but the "FWD" (forward) motor output L.E.D. is off; the fault is the the Phase 5 OPL microprocessor controller itself. 1) If the drive (basket(tumbler) motor is not operating and the "FWD" indicator is on; then the problem (fault) is elsewhere (i.e., external of the Phase 5 OPL microprocessor controller). "REV" Output L.E.D. Indicator - If the dryer is started and the blower motor is operating but the drive (tumbler/basket) motor is not, yet the Phase 5 OPL microprocessor controller's display "REVERSE" indicator dot is on, but the "REV" (reverse) motor output L.E.D. is off; the fault is the Phase 5 OPL microprocessor controller itself. If the drive (tumbler / basket) motor is not operating and the "REV" (reverse) indicator is on; then the problem (fault) is elsewhere (i.e. external of the Phase 5 OPL microprocessor controller). 5. "DOOR" L.E.D. indicator should be on all the time (even if the dryer is not running) unless the main door or lint drawer is open or there is a problem (open circuit in the maun door or lint drawer switch circuit). NOTE: If the dryer is started (L.E.D. display indicator dots are on) and there are no outputs (heat and / or motor output L.E.D/s are off) and the "dOOr" input L.E.D. is on, the fault is in the Phase 5 OPL microprocessor controller itself. If the failure was elsewhere (i.e., dryer's door switch circuit) the L.E.D. display would read "dOOr" if a keyboard entry was attempted. If the L.E.D. display indicators cure on the door L.E.D. input and motor / heat output L.E.D/s are on and the motor and / or heat is not active (on), then the problem is not the door switch circuit or the Phase 5 coin microprocessor controller and is elsewhere in the dryer. 46 L.E.D. Display/Codes The L.E.D. display informs the user of cycle status and program verification and displays important diagnostic and fault codes. 1. Display Operating Status a. Cycle in Progress - While the dryer is operating, the display will read which cycle is in progress. For example, in the drying cycle (mode), the display will read "dr," and in the cool down cycle (mode), the display will read "CL." b. Cycle Status - While a cycle is in progress, the display will show the progress of the cycle (load) that is being processed. 1) Automatic Drying Cycle - The cycle status portion of the display will show the percentage of extraction. 2) Timed (Manual) Drying Cycle - The cycle status portion of the display will show the drying or cool down time and will count downward until the programmed time has expired. c. Alternate Display Programs - Programming allows for the display to read just the cycle in progress or just the basket temperature or to flash back and forth from cycle in progress to basket temperature while the dryer cycle is in progress. Unless otherwise specified at the time of ordering the dryer, the microprocessor controller is programmed not to flash and to read cycle in progress. d. Indicator Dots - Located at the top of the display is a series of dots which indicate the various microprocessor controller output functions while a cycle is in progress. Illus. No. 3 - BLOWER MOTOR INDICATOR - This indicator dot is on whenever a cycle is in progress. In addition, when the anti-wrinkle program is active, this indicator dot will be on whenever the microprocessor controller is in the guard on time program. 1 CYCLE IN PROGRESS a. dr - DRYING CYCLE Û. CL - COOL DOWN CYCLE 2. CYCLE STATUS a, AUTOMATIC MODE DISPLAYS % OF EXTRACTION b. MANUAL MODE DISPLAYS DRYING TIME OR COOL DOWN TIME 3 ON INDICATOR. DRYER IS IN OPERATING MODE i HEAT ON INDICATOR 5. BASKET IN REVERSE MODE (C.C.W ) INDICATOR 6. BASKET IN FORWARD MODE IC.W) INDICATOR MANOSSi 47 Illus. No. 4 - HEAT INDICATOR -This indicator dot is on whenever the microprocessor controller is calling for the heating unit to be active (on). / Illus. No. 5 - REVERSE INDICATOR - This indicator is functional for models with the reversing action option only. This indicator will be on when the basket is in the reverse (counterclockwise) direction. Illus. No. 6 - FORWARD INDICATOR - This indicator dot is functional only for models with the reversing action option only. This indicator will be on when the basket is in the forward (clockwise) direction. In addition, when the anti-wrinkle program is active, this indicator dot will be on whenever the microprocessor controller is in the guard on time program. c. L,B,P DISPLAY CODES A Slope Factor AUtO Automatic Mode (Patent No. 4,827,627) ArEv Alway...

Otros modelos de este manual:
Secadoras - AD-120 (3.81 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría