Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario American Dryer Corp., modelo /T75

Fabricar: American Dryer Corp.
Tamaño del archivo: 918.7 kb
Nombre del archivo: 06a0c5e0-a734-4f86-bdba-8d6cc07dcb83.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Important ! The dryer should be located where a minimum amount of exhaust ducting will be necessary. The dryer must be installed with adequate clearance for air openings into the combustion chamber. Caution ! This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint buildup. Important The dryer must be installed in a location/ ! environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C). Unpacking/Setting Up _________________ Remove protective shipping material (i.e., plastic wrap and optional shipping box) from the dryer. Important ! Dryer must be transported and handled in an upright position at all times. The dryer can be moved to its final location while still attached to the skid or with the skid removed. To remove the skid from the T20, simply lift the unit off of the skid; for the T30, T50, or T75, locate and remove the 2 bolts securing the base of the dryer to the wooden skid. One is located at the center rear and the other is at the center front. With the skid removed, use caution and assure all four leveling legs are fully retracted if the dryer is to be slid into its final position. Leveling Dryer The dryer is equipped with 4 leveling legs, 1 at each corner of the base. For optimum performance the dryer should be level front-to-back and side-to-side. Dryer Enclosure Requirements _______ Commercial Type II (T20, T30, T50, T75) Bulkheads and partitions should be made of noncombustible material. Note Allowances must be made for opening the control ! door. A The requirement to allow the door to open completely for the T20 is 30-inches (76.2 cm), T30 is 33-inches (83.8 cm), and T50 and T75 is 40-inches (101.6 cm). B A minimum overhead clearance of 6-inches (15.24 cm) is required. C Dryer should be positioned a minimum of 12-inches (30.48 cm) away from the nearest obstruction. 24-inches (60.96 cm) is recommended for ease of installation, maintenance, and service. D 1/16” (1.5875 mm) minimum is required. E Flooring should be level or below dryer cabinet for ease of removing panels during maintenance. F Dryers may be positioned sidewall to sidewall, however a 1/16” (1.5875 mm) minimum allowance must be made for the opening and closing of the control door, along with the removal of panels during maintenance. 14 JLA Limited 113429-9 113429-9 Telephone 01422 822282 15 EXAMPLE: For T50, 2 unrestricted openings measuring 6-inches by 24-inches (15.24 cm by 60.96 cm) are acceptable. If a closet door is installed: unobstructed air openings are required. The air openings shall be located 3-inches (7.62 cm) from the lower opening (above floor level) and upper opening (below ceiling). The total free area of the air openings in the door shall not be less than 130 inch2 (838.708 cm2) for T20; 179 inch2 (1154.836 cm2) for T30; and 293 inch2 (1890.319 cm2) for T50. Louvered doors with equivalent air openings are acceptable. No other fuel-burning appliance shall be installed in the same closet as the dryer. Fresh Air Supply Requirements _______ When the dryer is operating, it draws in room air, heats it, passes this air through the tumbler, and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition problems and sail switch “fluttering” problems may result, as well as premature motor failure from overheating. The dryer must be installed with provisions for adequate combustion and make-up air supply. Air supply (make-up air) must be given careful consideration to ensure proper performance of each dryer. As a general rule, an unrestricted air entrance from the outdoors of 110 inch2 (710 cm2) is required for each T75, 90 inch2 (580 cm2) for each T50, 55 inch2 (354 cm2) for each T30, and 40 inch2 (258 cm2) for each T20. (Based on 1 inch2 [6.5 cm2] per 1,000 Btu [252 kcal].) It is not necessary to have a separate make-up air opening for each dryer. Common make-up air openings are acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to all the dryers. To compensate for the use of registers or louvers used over the openings, this area must be increased by approximately 33%. Make-up air openings should not be located in an area directly near where exhaust vents exit the building. Allowances must be made for remote or constricting passageways or where dryers are located at high altitudes or predominantly low pressure areas. Note Component failure due to dry cleaning solvent fumes will void the warranty. Domestic Type I (T20, T30, T50 Only) ! ! ! EXAMPLE: For a bank of 4 T30 dryers, 2 unrestricted openings measuring 10-inches by 11-inches (25.4 cm by 27.94 cm) are acceptable. Important Make-up air must be free of dry cleaning solvent fumes. Make-up air that is contaminated by dry cleaning solvent fumes will re...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría