Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Lincoln Electric, modelo 10A

Fabricar: Lincoln Electric
Tamaño del archivo: 532.79 kb
Nombre del archivo: 02c6ecda-48f4-41b7-87da-d158f9b733f8.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Built on the enduring and trusted foundation of the NA-5 controller and the innovations of the new Power Feed 10M wire feeder, the Power Feed 10A Controller is the next generation in automatic submerged arc feeding. Designed for use with the Power Wave AC/DC 1000 power source, the Power Feed 10A eliminates the need for a separate AC and DC controller, making this powerful hard automation system controllable, adaptable and easy to use. The user-friendly control panel offers a single-point of control over the entire welding cell, including the Power Wave's Waveform Control Technology™, delivering an unprecedented level of control over wave balance, amplitude and frequency. Processes Submerged Arc Advantage Lincoln • Versatile system set-up options for stand-alone or PLC configurations help you customize the weld cell to make your operations as efficient as possible. • Lincoln’s Waveform Control Technology™ gives you the ability to select the right waveform for each application. • The Power Feed 10A Controller provides clear dual digital display of set-up and weld modes, six memories, AC controls, strike/start/end options, travel stop/start, and timers. • Controls can be adjusted on-the-fly to change penetration and/or deposition rates with Variable Frequency, Variable Amplitude and Variable Balance. • Easy-to-use switch panel can be removed and used as a Remote Control Pendant to create a versatile work station set-up. • The Power Feed 10SF and Power Feed 10S wire drive systems are reliable and durable. • The motor conversion kit allows the use of existing NA-3, NA-4, and NA-5 feed head mounting hardware. • Manufactured under a quality system certified to ISO 9001 requirements and ISO 14001 environmental standards. • Three-year warranty on parts and labor. Description Output Input Unit Includes: 40 VDC Power Feed 10A Control Box, Remote Pendant, 10-ft. Remote Pendant Cable Unit Requires: Power Wave AC/DC 1000 power source, and either the K2312-1 Power Feed 10SF Wire Feed Head for fixed hard automation, or the K2370-1 Power Feed 10S Head for mounting to a Lincoln TC-3 Travel Carriage. (other options may apply.) Recommended General Options Power Feed 10SM Motor Conversion Kit (converts Lincoln NA-style wire drives), ArcLink Cable, Flux Hopper, Feeder Control Cable (14-pin to 14pin and 5-pin to 5-pin), Contact Nozzle Assembly, Contact Jaw Assembly, Positive Contact Assembly, Linc-Fill Attachments, Narrow Gap Deep Groove Nozzle, Concentric Flux Cone Assembly, Tandem Arc Framework, Tandem Reels, Twinarc Contact Assemblies, Tiny Twinarc Assemblies, Tiny Twinarc Solid Wire Straightener, TC-3 Travel Carriage, Vertical Lift Adjuster, Horizontal Adjuster, Wire Reel Assembly for 50-60 lb. Coils, Spindle Kit – 2 in. hub, SpreadArc Oscillator, Flux Screen, Magnetic Flux Screen Separator Recommended Power Source Option Power Wave AC/DC 1000 Order K2362-1 Power Feed 10A Controller Wire Feed Wire Size Range (1) Dimensions Product Product Number Input Rated Output Gear Speed Range (1) Inches (mm) H x W x D Net Weight Name Power (1) Current / Duty Cycle Box ipm (m/min) Solid Inches (mm) lbs (kg) Power Feed 10A K2362-1 40 VDC 1000A/100% 142:1(1) 10-200 (.25-5.08) 5/32 - 7/32 (4.0 - 5.6) 15 x 13 x 4 25 (11.3) Controller with (381 x 259 x 102) Wire Drive 95:1(1) 10-300 (.25-7.62) 1/8 - 5/32 (3.2 - 4.0) TECHNICAL SPECIFICATIONS (1) 142:1 gear box is standard. Conversion Kit supplied for conversion to 95:1 with Wire Drive (K2370-1, K2312-1, or K2311-1) Publication E9.165 1/05 A CLOSER LOOK FEATURES Power Feed 10A Control Panel The Power Feed 10A control panel controls and monitors the advanced capabilities of the Power Wave AC/DC 1000 in a single, simple, easyto- understand user interface display panel. The Power Feed 10A communicates using ArcLink, and can easily integrate with custom controls and PLCs, in multiple configurations. A Closer Look Dual Display Dual Encoder Panel 3. 1. Wire feed speed (WFS) or amps. 1. 2. 2. Voltage 3. Arc Established Indicator - illuminates when a true arc has been established. 4. Status LED - indicates system component ArcLink communication ® status. Normal operation is a steady green light. 4. 4.5.1. 2. Switch Panel 1. START – Starts the weld sequence, using strike controls. 2. STOP – Stops the weld sequence, using crater/burnback controls. 3. 3. INCH – Up/Down. Inches wire up or down without welding current 4. FLUX FILL– Activates flux hopper. 5. TRAVEL– Controls motion in either manual or automatic modes. Remote Pendant - The switch panel can be removed and used as a handheld pendant for remote control. 1. 14-PIN Remote Control Connector 2. 4-PIN TC-3 Carriage Connector 3. 3-PIN Flux Hopper Receptacle 4. 5-PIN ArcLink Connector 5. Auxiliary Circuit Access Holes 1. 2.3. 4. 5. Power Feed 10A Controller [2] A CLOSER LOOK PERFORMANCE WHAT IS NEXTWELD®? Nextweld integrates Lincoln’s technologies, processes and products to create a comprehensive, flexible...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría