Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Certified International, modelo 121718B

Fabricar: Certified International
Tamaño del archivo: 32.29 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


connected to the DC power source with a 3 Amp 5.02.3 Check the connection to the fuse within 18" of the source. The cable clamp remote switch, +12VDC, +24VDC or +48VDC strain relief should be used to secure the field wires.must be present at the violet wire for the unit to 3.06.3 The switch should be mounted at a operate. If not, check any in-line fuses in the convenient location in a listed outlet box with +12VDC, +24 or +48 VDC remote switch circuit. approved strain relief. The in-line fuse to be 5.02.4 Observe the fault indicating lights mounted on appropriate fuse holder.on the front of the inverter. 3.06.4 NOTE: A remote switch, must be a) The Low battery light indicates a low installed to operate the inverter. You may use battery condition. Switch the inverter “Off” for 5 several switches or relays in parallel in lieu of one seconds, then “On” again. The light coming on remote switch.again indicates a fault in the battery wiring, battery 3.07 120 VAC Outputcapacity and voltage or the fuse. 3.07.1 CAUTION: Do not connect another b) The Overload light indicates an output source of AC power directly to the output of the wiring short circuit or a load that is too large for the inverter. This will result in damage to the inverter power rating of the inverter. Switch the inverter that is not covered under warranty!“Off”, remove the short circuit or excessive load 3.07.2 The 120 VAC output is provided at from the output, then switch the inverter back the GFCI protected female receptacle cord at-“On”. tached to the inverter.c) The High temp. light indicates the inverter has overheated. The unit will automatically turn 4. START UP / OPERATIONback on when it has cooled to 400C (1040F). 4.01 To operate the inverter turn the remote 5.03 If the above steps are completed and the switch to “On”. Make sure that the output breaker is inverter still will not operate satisfactorily call Airpax reset.Dimensions, Inc. for a return authorization number. 4.02 Turn the switch to “Off” when the inverter is not in use. 5. TROUBLESHOOTING 5.01 Airpax Dimensions Inc. offers free phone consultation concerning installation or troubleshooting. Call the Customer Service Department at: 1-800-553-6418 or 1-651-653-7000 Fax:651-653-7600; e-mail: inverterinfo@Airpax.net 5.02 If the inverter fails to operate correctly, use the following troubleshooting procedure. Page 4 FRONT VIEW WIRING DIAGRAM FOR MODEL 48Z8NV Note 1: Remote switch to be connected to +12VDC, +24VDC or +48VDC depending on inverter model. Output Breaker Inv. Power Fig #1 Low battery Overload High temp. Dimensions GFCI Chassis Bonding Lug Remote On/OffBattery Input A.C. Output Ground Fuse 120VAC, 60Hz Output Remote On/Off Switch Fuse Red (+) Black (-) + -+ -+ -+ 12VDC 12VDC 12VDC 12VDC Four batteries in series Page 5 Limited Warranty Terms & Conditions SHIPPING TERMS F.O.B. St. Paul Minnesota. Freight prepaid and billed, subject to prior credit approval. MINIMUM ORDER $50.00 Net Price LOSS OR DAMAGE Loss or damage in transit are the responsibility of the carrier. Any claim should be filed with the delivering transport company. Invoice, Bill of Lading and Delivery receipt with damage noted therein must accompany any claims for freight damage. Claims for shortage and lost shipments must be made in writing to Airpax Dimensions, St. Paul, MN within 10 days of date of shipment. Claims not reported within this time frame will not be honore...

Otros modelos de este manual:
Máquinas de soldar - 24Z8NV (32.29 kb)
Máquinas de soldar - 48Z8NV (32.29 kb)
Máquinas de soldar - 12Z8NV (32.29 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría