|
Resumen del manual
Attention! Priere de lire attentivement la presente notice avant l'installation et la mise en service. Attentie! Lees deze instructies voor de installatie en ingebruikname aandachtig door. .Atencion! Lea con detenimiento estas instrucciones antes de la instalacion y de la puesta en servicio. ENG ENG Table of Contents 1 Technical Specifications 6.1 Tips for TIG-Welding 2 Scope of Application 7 Overloads 2.1 Information 8 Trouble Shooting 3 Commissioning 9 Safety Information 4 Description 9.1 Protection against Electrical Accidents 5 Operation 10 Wiring Diagram 6 TIG-Welding (optional) 1 Technical Specifications Invert 130/40 Invert 130/60 Mains voltage: 1 ~ 230/240 V 1 ~ 230/240 V Mains frequency: 50 - 60 Hz 50 - 60 Hz Setting range: 100 V 100 V Stromeinstellbereich: 5 - 130 A 5 - 130 A Power input: manual arc 4.5 kVA 4.85 kVA TIG 3.1 kVA 3.1 kVA Operating voltage: manual arc 20,2 - 25,2 V 20.2 - 25.2 V TIG 10,2 - 15,2 V 10.2 - 15.2 V Max. current draw: 27 A 27 A Mains fuse: 16 A time-lag 16 A time-lag Duty cycle at max. manual arc 130 A / 50 % / 35 % 130 A / 80 % / 55 % ouput (25 °C/ 40 °C): TIG 130 A / 40 % / 30 % 130 A / 60 % / 40 % Operating modes: manual arc/TIG manual arc/TIG Setting: stepless stepless Suitable electrodes manual arc from 1.5 mm O from 1.5 mm O TIG for steel 0.3 mm and up for steel 0.3 mm and up Protection class: IP 23 S IP 23 S Cooling: F F Insulation class: F F Temperature range: operation -10 °C - +40 °C -10 °C - +40 °C Dimensions ( l x w x h): 255 x 110 x 210 mm 235 x 110 x 220 mm Weight: 4.9 kg 4.9 kg Operating conditions: relative humidity 10-80 % relative humidity 10-80 % 2 Scope of Application The inverter welding machines are designed as a compact, easy to operate and field-safe unit. With it all metals (except aluminium) can be welded. Special consideration has been given to stick electrode welding capabilities, i.e. vertical-down welding. Due to its wide range of welding current setting the Invert 130 is very versatile, e.g. for sheet metal and steel welding. In addition there is the capability of TIG welding with scratch start. With this welding process steel, stainless steel and NF-metals (except aluminium) can be welded, e.g. thin plate welding or car body work. Product Liability/Warranty This product shall only be used as specified. Any other use requires the written consent of Metabo GmbH, Business Unit Elektra Beckum, P.O.Box 1352, D-49703 Meppen, Germany. Please contact your dealer for any warranty claims. Warranty work will essentially be carried out by service centres authorised by us. Repairs beyond the warranty period may be carried out only by our authorised service centres. Please preserve all repair invoices! We reserve the right to make technical changes! 2.1 Information - Shown On Type Plate The following explanations refer to the numbered boxes shown in Figure 2.3 according to ISO/IEC 60974-1. a) Identification Box l Name and address of the manufacturer or distributor or importer and, optionally, a trade mark and the country of origin, if required Box 2 Type (identification) as given by the manufacturer Box 3 Traceability of design and manufacturing data, e.g. serial number Box 4 Welding power source symbol (optional) e g Single-phase transformer Single- or three-phase transformer-rectifier Single- or three-phase static frequency converter-transformer-rectifier Three-phase motor-generator Three-phase motor-generator-rectifier Three-phase rotating frequency Converter Single-phase combined a.c. and d.c. power source Engine-a.c. generator Engine-generator-rectifier Box 5 Reference to this Standard confirming that the welding power source complies with its requirements b) Welding Output Box 6 Box 7 Box 8 Box 9 Box 10 Box 11 Box 12 Box 13 Boxes Welding process Symbol e.g.: Manual metal arc welding with covered electrodes Tungsten inert-gas welding Metal inert and active gas welding including the use of flux cored wire Selfshielded flux cored arc welding Submerged arc welding Symbol for plasma cutting Symbol for plasma gouging Symbol for welding power sources which are suitable for supplying power to welding operations carried out in an environment with increased hazard of electric shock (if applicable). Welding current symbol e.g.: Direct current Alternating current, and additionally the rated frequency in hertz e.g.: ~50 Hz U0... V Rated no-load voltage a) Arithmetic mean value in case of direct current b) RMS value in case of alternating current c) Ur... V Reduced rated no-load voltage in case of a voltage reducing device d) Us... V Switched rated no-load voltage in case of an a.c. to d.c. switching device ... A/... V to... A/... V Range of output, rated minimum and maximum welding current and their corresponding conventional load voltage. X Duty cycle (duty factor) symbol. I2 Rated welding current symbol. U2 Conventional load voltage symbol. 11a, 11b, 11c ...% Values of the duty cycle (duty factor). 12a, 12b, 12c ... A Values of the rated welding current. 13a, ...
Otros modelos de este manual:Máquinas de soldar - Invert 130/40 (966.41 kb)
Máquinas de soldar - Invert 130/60 (966.41 kb)
Máquinas de soldar - Invert 130/60 (966.41 kb)