Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario Panasonic, modelo TH-50PF20U

Fabricar: Panasonic
Tamaño del archivo: 1.36 mb
Nombre del archivo:

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere


Otros manuales para este modelo:
TV - TH-50PF20U (1.64 mb)es

Resumen del manual


• If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer. • S1A and S1B of Command IMS are available only when a dual input terminal board is attached. RS-232C Straight cable (Female) D-sub 9p 6789 345 12 (Male) Pin layout for SERIAL Terminal Signal names for D-sub 9P connector Pin No. 2 3 5 4 • 6 7 8 1 • 9 Details R X D T X D GND Non use (Shorted in this set) NC These signal names are those of computer specifications. Command Command PON POF AVL AMT IMS DAM Parameter None None ** 0 Control details Power ON Power OFF Volume 00 - 63 Audio MUTE OFF 1 None SL1 S1A S1B VD1 YP1 HM1 DV1 PC1 None ZOOM FULL JUST NORM SJST SNOM SFUL ZOM2 Audio MUTE ON Input select (toggle) SLOT input (SLOT INPUT) SLOT input (SLOT INPUT A) SLOT input (SLOT INPUT B) VIDEO input (VIDEO) COMPONENT/RGB IN input(COMPONENT) HDMI input (HDMI) DVI-D IN input (DVI) PC IN input (PC) Screen mode select (toggle) ZOOM (For Video/SD/PC signal) FULL JUST (For Video/SD signal) 4:3 (For Video/SD/PC signal) JUST (For HD signal) 4:3 (For HD signal) H-FILL (For HD signal) ZOOM (For HD signal) With the power off, this display responds to PON command only. INPUT MENU -/ VOL +/ ENTER/ 13 Power Indicator Remote Control Sensor Power ON / OFF Connecting the AC cord plug to the Plasma Display. Connecting the plug to the Wall Outlet. Note: When disconnecting the AC cord, be absolutely sure to disconnect the AC cord plug at the socket outlet fi rst. Press the Power switch on the Plasma Display to turn the set on: Power-On. Power Indicator: Green Press the button on the remote control to turn the Plasma Display off. Power Indicator: Red (standby) Press the button on the remote control to turn the Plasma Display on. Power Indicator: Green Turn the power to the Plasma Display off by pressing the switch on the unit, when the Plasma Display is on or in standby mode. Note: During operation of the power management function, the power indicator turns orange in the power off state. Power ON / OFF PC FULL NANODRIFT English (UK) Deutsch Francais Italiano Espanol ENGLISH (US) РусскийOSD LANGUAGE SETSELECT PRESENT TIME SETUP PRESENT TIME OF DAY MON 99:99 SET PRESENT TIME OF DAY 99:99 DAY MON PRESENT TIME SETUP PRESENT TIME OF DAY MON 99:99 SET PRESENT TIME OF DAY 10:00 DAY TUE LANDSCAPE PORTRAIT DISPLAY ORIENTATION From the second time on, the below screen is displayed for a while (setting condition is an example). When first switching on the unit Following screen will be displayed when the unit is turned on for the fi rst time. Select the items with the remote control. Unit buttons are invalid. OSD LANGUAGE PRESENT TIME SETUP DISPLAY ORIENTATION 1 Select the language. 2 Set. 1 Select “DAY” or “PRESENT TIME OF DAY”. 2 Setup “DAY” or “PRESENT TIME OF DAY”. 1 For vertical installation, select “PORTRAIT”. 2 Set. Notes: • Once the items are set, the screens won't be displayed when switching on the unit next time. • After the setting, the items can be changed in the following menus. OSD LANGUAGE PRESENT TIME SETUP DISPLAY ORIENTATION 1 Select “SET”. 2 Set. Selecting the input signal Press to select the input signal to be played back from the equipment which has been connected to the Plasma Display. Input signals will change as follows: PC VIDEO COMPONENT* HDMI DVI VIDEO: Video input terminal in AV IN (VIDEO). COMPONENT*: Component or RGB input terminal in COMPONENT/RGB IN. HDMI: HDMI input terminal in AV IN (HDMI). DVI: DVI input terminal in DVI-D IN. PC: PC input terminal in PC IN. * “COMPONENT” may be displayed as “RGB” depending on the setting of “COMPONENT/RGB-IN SELECT”. When an optional Terminal Board is installed: PC SLOT INPUT VIDEO COMPONENT HDMI DVI SLOT INPUT: Input terminal in Terminal Board Note: When a Terminal Board incompatible with the Plasma Display is installed, “NON-COMPATIBLE FUNCTION BOARD” is displayed. INPUT MENU ENTER/+/VOL-/ INPUT MENU ENTER/+/VOL-/ When a Terminal Board with dual input terminals is installed: VIDEO HDMI DVICOMPONENTSLOT INPUT A SLOT INPUT B SLOT INPUT A, SLOT INPUT B: Dual input terminal in Terminal Board. PC Notes: • Selecting is also possible by pressing the INPUT button on the unit. • Outputs the sound as set in “Audio input select” in the Options menu. • Select to match the signals from the source connected to the component/RGB input terminals. • In 2 screen display, the same input mode cannot be selected for the main picture and sub picture. • Image retention (image lag) may occur on the plasma display panel when a still picture is kept on the panel for an extended period. The function that darkens the screen slightly is activated to prevent image retention, but this function is not the perfect solution to image retention. Basic Controls Main Unit Remote control sensor INPUT MENU ENTER/+/VOL-/ Main Power On / Off Switch Power Indicator The Power Indicator will light. Volume Adjustment Volume Up “+” Down “–” When the menu screen is displayed: “+” : press to move the cursor up “–” : pr...

Otros modelos de este manual:
TV - TH-42PF20U (1.36 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría