Otros manuales para este modelo:
Resumen del manual
On/Off Timer
14
ʳ g
E0
Input value: Byte1 - Byte2 - Byte3…Byte9
(1) Byte1[3:0]: The Number of the On/Off
Timer. There are total y 7 On/Off Timers, and
this byte is used to selected which timer is
going to be accessed.
(2) Byte1[7:4] is reserved, should be 0.
(3) Byte2~9 are reserverd, should be 0x00.
Return value: Byte1 - Byte2 - Byte3…Byte9
(1) Byte1[3:0]: Should retuen the same value See the return value examples below:
as Byte1 at Input value.
Ex: Byte1=0x01 means the Timer no.1 is
Byte1[7]: Reserved, should be 0.
selected and disable.
Byte1[6]: The Timer is enable or not.
Ex: Byte1=0x41 means the Timer no.1 is
Byte1[6]=1 means enable.
select and enable, and its both On and Of
Byte1[5]: The On Timer is enable or not.
Timers are disable.
Byte1[5]=1 means enable.
Ex: Byte1=0x61 means the Timer no.1 is
Byte1[4]: The Off Timer is enable or not.
select and enable, and its On Timer is enable,
Byte1[4]=1 means enable.
Off Timer is disable.
(2) Byte2: The Day of the On/Off Timer. bit0 Ex: Byte1=0x71 means the Timer no.1 is
for Sunday, bit1 for Monday, bit2 for Tuesday, select and enable, and its both On and Of
bit3 for Wednesday, bit4 for Thursday, bit5 for Timers are enable.
Friday, bit6 for Saturday, bit7 for Everday.
Ex: Byte1=0x53 means the Timer no.3 is
(3) Byte3: The Hour of the On Timer.
select and enable, and its On Timer is
Byte3=0x00~0x17.
disable, Off Timer is enable.
(4) Byte4: The Minute of the On Timer.
Ex: Byte2=0x02 means the Timer is on
Byte4=0x00~0x3B.
Monday.
(5) Byte5: The Hour of the Off Timer.
Ex: Byte3=0x08, Byte4=0x1E means the On
Byte5=0x00~0x17.
Timer is at 8:30.
(6) Byte6: The Minute of the Off Timer.
Ex: Byte5=0x17, Byte6=0x00 means the Off
Byte6=0x00~0x3B.
Timer is at 23:00.
(7) Byte7: Select the Video Source.
Ex: Byte7=0x00 means the selected Video
0x00=VGA, 0x01=HDMI1, 0x02=HDMI2,
Source is VGA.
0x03=AV, 0x04=YPbPr,
0x05=S-Video, 0x06=DVI,
0x07=DisplayPort, 0x08=SDI,
0x09=Multi-Media.
0x0A=Network, 0x0B=USB Display
0xFF=Default. Other values are reserved.
(8) Byte8~9 are reserved, and should be
0x00.
________________________________________________________________
V1.0
19 / 20
Commercial Display RS-232 Protocol
...Otros modelos de este manual: