Iniciar sesión:
Votos - 3, Puntuación media: 4.7 ( )

Manual de usuario Zenith, modelo H20H52DT

Fabricar: Zenith
Tamaño del archivo: 807.55 kb
Nombre del archivo: a426de10-706d-426a-acf1-df18146087a2.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The number moves slightly to prevent damage to the screen. The default is “0” or OFF. NOTE: When captions are on, the “ghost channel” is not displayed. 7-I. START VOLUME This function allows the Installer to determine the initial volume level setting when the TV is turned ON. This feature is useful for an in-house information channel, since the TV would always select that volume level when it is turned on. The range of values are 0- 63, 255. If 255 is selected, the current volume level will be retained in memory when the TV is turned off; at TV turn on, volume level is automatically set to the previous or last level. 8-I. MIN VOLUME (Minimum Volume) This function determines the minimum volume level allowable with the VOLUME (VOL) Up/Down control. In this way, for example, someone cannot set the volume too low to hear. The range is from 0 to 63—change values with ADJUST. The factory default is 0, which provides full range of volume control. It may be best to set the same value on every TV. NOTE: The minimum volume level cannot have a value setting higher than in the MAX VOLUME level (described below). 9-I. MAX VOLUME (Maximum Volume) This function determines the maximum volume level allowable with the VOLUME VOL Up/Down control. In this way, for example, someone cannot set the volume level high enough to disturb others. The range is 0 to 63, with 63 as the default which gives the user the full range of volume control. Change values with ADJUST keys. It may be best to set the same value on every TV. NOTE: The maximum volume level cannot have a value setting lower than the MIN VOLUME level (described previously). 10-I. MUTE DISABLE Enables or disables sound mute function. When set to 1, sound cannot be muted. When set to 0, sound can be muted. 11 KEY DEFEAT (Keyboard Defeat) When set to 1, it prevents the end user from accessing screen menus on the front panel—MENU, SELECT, and ADJUST do not function. When set to 0, those keys are functional. The menus can always be accessed with MENU on the remote. 12-I. IR BANKS EN. For direct access to a particular Channel Bank. When enabled, installer can access a channel bank by inputting the IR code for the bank. 13-I. SCAN MODE Allows variation in setting the On/Off with Channel UP/DOWN. You may opt for TV channels only; TV channels + Off/ON; TV channels + FM radio; TV channels + FM radio + Off/On with these settings for Scan Mode: Page 34 Installer Menus Installer Menu Items 14-I through 27-I: Detailed Descriptions. Scan mode Characteristics 0 Channel up/down keys change channels only. 1 Channel down below the lowest channel (or channel up higher than the highest) and TV turns off. Channel down below the lowest channel (or up higher than the highest) and TV goes to 2 FM radio. Channel down below lowest FM station (or Channel up higher than the highest) and TV channels return. Channel down below the lowest channel (or up higher than the highest) and TV goes to 3 FM radio. Press channel down below lowest FM station (or Channel up higher than the highest) and TV turns off. 14-I. STRT CH IN SM When set to 1, installs TV on/off event below the start channel at TV turn on. 15-I. SLEEP TIMER When set to 1, the SLEEP TIMER feature may be used (but no message is displayed prior to turnoff). When set to 0, the sleep timer is not available. 16-I. EN. TIMER Set to 1, timer function is available to user. Set to 0 to disable timer functions. (Clock must be set in order to use Timers.) 17-I. ALARM Gives you the option of making the alarm function available to the user. Set to 1, alarm function is available to user. Set to 0 to disable the Alarm function. Note: Clock must be set in order to set the Alarm. 18-I. RADIO Set to 1, for TVs with a Radio. Set to 0 to disable the Radio function, for TVs without a Radio. 19-I. NOT USED 20-I. FEATURE LEVEL Default set to ZEN 1 for Zenith IR remote control operation. Set O, P LBL for Zenith Private Label IR remote control operation. Warning: Do not set to “0” or remote will not control TV. Installer should leave item 20 FEATURE LEVEL set to 1 (default). 21-I. V-CHIP Set to 1 to activate V-Chip (Parental Control); have it available to user to filter, control, or restrict programming content. Set to 0 to turn V-Chip feature off, not available to user; no programming restrictions can be set. 22-I. MAX BLK HRS Set to 0 to 99 for the maximum V-Chip (Parental Control) block hours. Default is 12 blocking hours. 23-I. CAPTION LOCK Set to 1 to restore previous caption On/Off state after TV turns off. When set to 0, captions are always off, when TV is initially turned on. 24-I. TEXT MODE Determines whether TEXT 1, TEXT 2, TEXT 3, or TEXT 4 decoding is enabled when TEXT is turned on (either from the Setup Menu or directly with CC on the remote). TIP: Set Text Mode to 1 only if text is offered in your video System. 25-I. FUNCTION PRE. Set to 0 to suppress CHANNEL PREVIEW from the FUNCTION menu with some Pay-Per-View systems. 26-I. 6 KEY SYS Set to 1 for 6-k...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría