Iniciar sesión:
Votos - 4, Puntuación media: 5 ( )

Manual de usuario American Standard, modelo SELECTRONIC 605XTMV

Fabricar: American Standard
Tamaño del archivo: 519.92 kb
Nombre del archivo: Install_1889.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


customer's e-mail us at: faucetsupport@amstd.com For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369) NOTE TO INSTALLER: Please give this manual to the customer after installation. (In Toronto Area only: 1-905-3061093) Specifications Installation Adjust Temperature Service Replacement Parts 1 2 3 3 4 Installation InstructionsInstallation InstructionsSELECTRONIC™ Thermostatic Mixing Valve Certified to comply with ASME A112.18.1M © 2005 American Standard M968808 To learn more about American Standard Faucets visit our website at: or U.S. customer's e-mail us at: faucetsupport@amstd.com For Parts, Service, Warranty or other Assistance, NOTE TO INSTALLER: Please give this manual to the customer after installation. (In Toronto Area only: 1-905-3061093) 605XTMVSpecifications Installation Adjust Temperature Service Replacement Parts FAQ,s 1 2 3 3 4 5 MOUNTING HOLES 4-1/4" (108mm) 1-3/16" (46mm) 5" (126mm) 3-3/8" (85mm) 3-3/16" (33mm) 20" (508mm) Fig. 1 Roughing-in Dimensions Thermostatic Mixing valve • 3/8" stainless steel compression flex hoses, 20" length • meets ASSE 1016 • anti-scald protection TOOLS REQUIRED; Fig. 2 1 Channel Locks 2 Adjustable Wrench 3 Phillips Screwdriver 4 Flat Blade Screwdriver 5 Electric Drill & 1/4" Drill Bit 6 Tape Measure Fig. 2 1 2 3 4 56 10' Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Faucets Are Water Tested At Our Factory. Some Residual Water May Remain In The Faucet During Shipping. 1. Remove the Mixer and loose items from the carton. The picture below shows the Mixer and all loose items after the carton has been opened. 21 4 1. Electronics Mixing Valveand Enclosure 2. Supply Hoses 3. Mounting Kit 4. Installations instructions 3 please call 1-800-442-1902 (In Canada: 1-800-387-0369) 1 Fig. 5 1. Remove the bottom SUPPLY HOSE (1) from the SELECTRONIC ENCLOSURE (2). Fig. 3 2. Remove BOTTOM PLUG (3) from SELECTRONIC ENCLOSURE (2). Fig. 3 3. Remove 4 screws from MIXER ENCLOSURE COVER (2) and pull off COVER (2). Fig. 3b 4. Remove MIXING VALVE (7) from ENCLOSURE (3). 5. Install MIXER ENCLOSURE (4) under SELECTRONIC ENCLOSURE (2) as shown in Fig. (3a). Hold the MIXER ENCLOSURE (4) in that location and mark the four mounting hole locations as shown. Fig. (3a) NOTE: MIXER ENCLOSURE SUPPLY HOSES are 20" long. Distance between wall valves and MIXER ENCLOSURE (4) must be taken into consideration. 5. The ENCLOSURE (4) works best if secured to a wall stud or cross brace within the wall, using the SCREWS (5) supplied. If the MIXER ENCLOSURE (4) is to be installed on a tile or plaster wall the ANCHORS (6) and SCREWS (5) should be used. 6. For installations on drywall or tiled walls; use ANCHORS (6) and SCREWS (5) for securing MIXER ENCLOSURE (4) to finished wall. Drill four 1/4" dia. holes a minimum of 1-3/4" deep. Insert the four ANCHORS (6) flush with face of the finished wall. Align the MIXER ENCLOSURE (4) and Install the MOUNTING SCREWS (5). Tighten to secure MIXER ENCLOSURE (4) to mounting surface. 1. Install MIXING VALVE (1) back into ENCLOSURE. 2. Install FIBER SEAL WASHER (4) on MIXING VALVE NIPPLE (3). Hold MIXING VALVE (1) in place with one hand and with your other hand thread SWIVEL NUT (2) onto MIXING VALVE NIPPLE (3). Fig. 4. Use an adjustable wrench to tighten SWIVEL NUT (2). Fig. 4a 3. Replace ENCLOSURE COVER and tighten securely. 1. Turn off hot and cold water supplies before beginning. 2. Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies. Connection on MIXER supplies are 3/8" compression. Connect left supply to Hot and right supply to Cold wall supply. Use adjustable wrench to tighten connections. Do not over tighten. FIG. 5 3. Faucet supplies measure 20" from the bottom of the ENCLOSURE (3) base. Note: If additional supply length is required, installer must purchase parts separately. Important: If SUPPLY HOSES (1, 2) are too long, loop as to avoid kinking. 1 MOUNT ENCLOSURE; Fig. 3 2 CONNECT MIXING VALVE; Fig. 4 CONNECT MIXING VALVE TO WATER SUPPLIES; Fig. 5 3 2 Fig. 4 Fig. 4a 1 2 3 4 1 3 HOT COLD 2 2 ADJUSTABLE WRENCH WALL SUPPLIES INSTALLATION Fig. 3 Fig. 3a Fig. 3b 4-1/4" (108mm) 1-3/16" (46mm) 4 2 MOUNTING HOLES ILLUSTRATION SHOWN LESS MIXING VALVE 3 1 SUPPLIES WASTE LAVATORY RIM OR MOUNTING SURFACE ENCLOSURE MOUNTING HOLES 2 6 4 5 7 1. Adjust temperature by inserting a 4mm Hex Wrench into hex opening in the side of enclosure. Fig. 6. 2. To decrease temperature, rotate up. (clock-wise) 3. To increase temperature, rotate down. (counterclockwise) TO ADJUST TEMPERATURE; Fig. 6 4 Fig. 6 TO INCREASE TEMPERATURE TO DECREASE TEMPERATURE 4mm HEX WRENCH ADJUST TEMPERATURE 4 Fig. 6 TO INCREASE TEMPERATURE TO DECREASE TEMPERATURE 4mm HEX WRENCH ADJUST TEMPERATURE SERVICE 5 TO SERVICE CARTRIDGE; Fig; 7 1. Turn off water s...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría