Fabricar: Hunter Fan
Tamaño del archivo: 1.34 mb
Nombre del archivo: 42708.pdf
|
Resumen del manual
By using the pre-programmed settings, this thermostat can save you money by optimizing energy usage in heating and cooling. After setting the time and temperature scale, no additional action is needed to utilize the pre- programmed settings. Refer to the Default Programs Chart for detailed information about the pre-programmed settings. 34 AMPMprogramhold/returnsystemoffheatcool AMPMprogramhold/returnsystemoffheatcool METhoDS of opEraTion, ConT. 3. CrEaTing CuSToM prograMS • Program times can be set in 10 minute increments. • Program temperature can be set in increments of 1o F (1o C). • After 15 seconds of inactivity during programming, the thermostat will return to Normal Display mode. • When setting the program time, note the AM/ PM indicator. • Press Hold/Return at any time to exit Program mode. 1. Slide the system switch to HEAT or COOL to program the corresponding system. 2. Press Program to enter Program mode. (The LCD will begin to flash) 36 AMPMHEATCOOLSA2134SUMTWTHFprogramhold/returnsystemoffheatcool AMPMHEATCOOLSA2134SUMTWTHFprogramhold/returnsystemoffheatcool METhoDS of opEraTion, ConT. 3. Press Up or Down to change the hour. Press Program to save the hour and adjust theminute setting. 4. Press Up or Down to change the minute. Press Program to save the minute setting and adjustthe temperature. 5. Press Up or Down to set the temperature. Press Program again to move to the nextprogram number. (There are 4 programs per day. If you do not wish to assign all 4 programs per day set at least 2, keeping in mind that the total program time must equal 24 hours.) 6. Repeat steps 2-5 for the remaining days. 7. To review your program settings, press Program repeatedly to review the customized programs. (You can make changes at any time when the thermostat is in Program mode.) 8. Slide the system selector switch to the oppositeposition and repeat steps 2-5. FILTERfilter FILTERfilter iConS anD fEaTurES 1. INDIGLO® Night-Light - will backlight the display for easy viewing in the dark. Press any button to illuminate the light. (If no button is pressed after 5 seconds, the backlight will turn off.) note: if the thermostat shows a low Battery Warning, the backlight will not operate. follow the instructions on pages 42-43 to change batteries. 2. Filter change indicator - will flash after 400 hours of system use as a reminder to check or change your filter. Press and hold the Filter button for 3 seconds after changing the filter to reset the filter timer. (Pressing the Filter button for less than 3 seconds will cause the Filter change indicator icon to appear. The filter timer will not be affected unless the button is held for more than 3 seconds.) 40 HEATCOOLsystemoffheatcoolreset HEATCOOLsystemoffheatcoolreset iConS anD fEaTurES, ConT. 3. Span setting mode – allows you to adjust the system ON/OFF cycle rate. The default setting is 2 (the system cycles ON or OFF when the temperature is within 1o F (0.5o C) above and below the set temperature.) The span setting can be adjusted if your system is cycling too fast or too slowly. Press and hold both the Up and Down buttons until the word SPAN appears. Use the Up or Down button to adjust the span setting. (Up will increase your cycle time by allowing the system to run longer; Down will decrease your cycle time by causing the system to run for a shorter length of time.) Span settings remain the same for HEAT and COOL system settings. When batteries are installed, or the unit is RESET, the span cycle will revert to 2. PMCOOL 4MSTAGE 1 STAGE 2 PMCOOL 4MSTAGE 1 STAGE 2 iConS anD fEaTurES, ConT. 4. Low battery warning – indicates two stages of battery power shortage. When the batteries are detected as weak, the icon will flash until new AA alkaline batteries are installed. If the batteries become too weak for normal operation, the thermostat enters the second battery power shortage mode. When insufficient battery power is left, the battery icon will flash alone on the display and your system will turn off. The system will remain off until new batteries are installed. after removing the batteries, program and time settings will remain in memory for one minute. if all battery power is lost, programs and time settings will be erased. The thermostat will resume normal operation after new batteries are installed. 44 hold/return hold/return iConS anD fEaTurES, ConT. 5. Auto recovery – allows heating and cooling systems to gradually recover from an energy-saving setpoint temperature to a comfort setpoint temperature. Auto recovery calculates the time needed to adjust the temperature to the next program setting. When the thermostat is in Auto Recovery mode, the display will flash alternating messages of RECO and the time. Auto Recovery can be disabled by sliding the recovery switch on the back of the circuit board to the disable position. (Auto Recovery will not operate if Permanent or Temporary holds are on.) Press Hold/Return during the Auto Recovery process to manually cancel the r...
Otros modelos de este manual:Los termostatos - SET & SAVE 44155C (1.34 mb)
Los termostatos - SET & SAVE 44155C (1.34 mb)