Iniciar sesión:
Votos - 3, Puntuación media: 5 ( )

Manual de usuario Hunter Fan, modelo 44377W

Fabricar: Hunter Fan
Tamaño del archivo: 2.43 mb
Nombre del archivo: 44045.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


4. Using the provided stickers, label each wire according to the Wire Labels chart. (If the terminals are not labeled, contact a qualified HVAC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification. *If wires marked Y & C are both present, C may be a Common wire and should not be used. If you have a wire marked C, do not connect it to any terminal. This wire is used only for non-battery powered thermostats. 5. Do not let the wires slip back into the wall during disconnection. You may want to secure the wires to the wall as you disconnect them. After all wires are labeled, disconnect each wire and remove the existing wall plate. (Any unused wires should be capped with an approved electrical connector, such as electrical tape.) 12 W/BRCGY/ 0Y1 W/BRCGY/ 0Y1 installing the thermostat INSTALLING THE WALL PLATE 1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, visually level the wall plate and mark the wall for two holes. 14 WRCYG WRCYG installing the thermostat, cont. 4. Remove the wall plate and drill two 3/16” holes where marked. 5. Tap the plastic anchors into the holes until they are flush with the wall. (Do not use plastic anchors if you encounter a stud in the wall.) 6. Reposition the wall plate on the wall, pulling the wires through the opening. Insert the mounting screws through the wall plate and into the anchors. Verify that the wall plate is visually level and securely tighten both screws. 16 GRCRHY/0W/BRCGY1Y/0W/BY1Terminal Shield GRCRHY/0W/BRCGY1Y/0W/BY1Terminal Shield 17 iNStalliNg the thermoStat, coNt. CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide bothan RH and RC wire. If you have both an RH and RC wire, remove this jumper. If you do not have both an RH and RC wire, leave the jumper in place. 2. Match and connect the wires from the wall to the terminals as shown. Wires should be inserted behind the black terminal shields. Tighten each screw after the connection has been made. (The ends of any extra wires should be individually wrapped in electrical tape and carefully pushed back into the wall.) 3. Push any excess wire length back into the wall to prevent interference. GRCRHYWJumper iNStalliNg the thermoStat, coNt. CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide bothan RH and RC wire. If you have both an RH and RC wire, remove this jumper. If you do not have both an RH and RC wire, leave the jumper in place. 2. Match and connect the wires from the wall to the terminals as shown. Wires should be inserted behind the black terminal shields. Tighten each screw after the connection has been made. (The ends of any extra wires should be individually wrapped in electrical tape and carefully pushed back into the wall.) 3. Push any excess wire length back into the wall to prevent interference. GRCRHYWJumper 18 DISABLE ENABLE RECOVERY HG HE W/B Y/O RH RC G SYSTEM TYPE STD HP Y1 FAN OPTION AM HEAT TThermostat Cover System Switch Fan Switch DISABLE ENABLE RECOVERY HG HE W/B Y/O RH RC G SYSTEM TYPE STD HP Y1 FAN OPTION AM HEAT TThermostat Cover System Switch Fan Switch installing the thermostat, cont. ATTACHING THE THERMOSTAT Lift the thermostat cover and set the SYSTEM switch to OFF and the FAN switch to AUTO. 1. Fan option - Locate the HE/HG switch on the back of the thermostat. Set the switch to HG (default) for gas furnace and oil burners. Set the switch to HE for electric furnaces. (The switch has no effect when the system is set to cooling mode.) 2. Recovery - Locate the AUTO REcOvERY switch on the back of the thermostat. If you wish to use the Auto Recovery feature, verify that the switch is in the ENABLE position. If you do not wish to use this feature, simply change the switch to the DISABLE position. See pages 44-45 for more information. 3. System type - Locate the SYSTEM TYpE switch on the back of the thermostat. Select either STD (Standard) or HP (Heat Pump) to match your system. 20 12front cover Tab 12front cover Tab installing the thermostat, cont. 4. Place the top of the thermostat over the two tabs on the wall plate. Press the thermostat onto the wall plate and press to snap the bottom tab into place. Note: Do not force the thermostat onto the wall plate, as the terminal pins may be damaged. If the thermostat does not snap into place properly, the unit may not work. 5. Lift the front cover and insert two AA alkaline batteries. 6. Restore power at the electrical panel or fur...

Otros modelos de este manual:
Los termostatos - 44377W (2.43 mb)
Los termostatos - 44377W (2.43 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría