Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Aube Technologies, modelo 40170

Fabricar: Aube Technologies
Tamaño del archivo: 714.5 kb
Nombre del archivo: 42998.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


2 24 05060780 90Thermometer Battery Indicator 05060780 90Thermometer Battery Indicator indicators and adustment indicators and adustment 1. The Thermometer indicates the room temperature. 2. The Battery Indicator displays two battery conditions. The first warning is the Weak Battery Warning, indicated by the Battery Indicator flashing once approximately every three seconds. When this warning appears, install two fresh AA alkaline batteries at your earliest convenience. 3. The second warning is the Shut-down Indicator, indicated by the Battery Indicator flashing approximately twice every second. When this warning appears, the thermostat is shut down and will turn your system OFF. Your system will remain shut-off until you install two fresh AA alkaline batteries. 2 SPAN Span Adjust SPAN SPAN Span Adjust SPAN 2 indicators and adjustments, cont. Your thermostat is preset to cycle your system off and on at 1oF above and below the Set Temperature. For maximum system efficiency and a sustained comfortable temperature your system should cycle 3 - 5 times per hour. If your system is cycling either too often or not often enough, then use a small Phillips-head screwdriver and the Span Adjust to change the cycle time. 1. Remove the top cover from the thermostat. 2. To make your system run LONGER, turn the SpanAdjust clockwise. 3. To make your system run SHORTER, turn the SpanAdjust counter clockwise. 4. Reattach the top cover to the thermostat. note: the span range is 0.6of - 3of. the span setting remains the same in both the heat and cool modes and can be changed regardless of what position the system switch is in. 27 1. My heating or cooling will not turn on or off. 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b. Wait. There may be as much as a 4-minute delay before the system turns on or off to protect the compressor. 1 c. Check the circuit breakers and switches to ensure there is enough power to the system. 1 d. Replace the batteries with fresh AA alkaline batteries. 1 e. If applicable, make sure the furnace blower door is closed properly. 1 f. If your system has 4 wires, ensure the jumper wire is installed between the RC and RH terminals. ............................................................................................. 2. My system continues to operate when the thermostat is in the off position. 2 a. Replace unit. 28 troubleshooting troubleshooting Is there help on the web? Yes. Visit for more information. ............................................................................................. Can’t I just call someone? Sure. Our Technical Support Group is available from 8 am to 5 pm CST. They may be reached toll-free at 1-888-830-1326. 29 4-wire Heat/Cool System G Rc Rh WY Fan Relay Heat/Cool 24V Supply Cool Contactor Heat Relay or Valve X Jumper 5-wire Heat/Cool System G Rc Rh Fan Relay Heat 24V Supply W Heat Relay or Valve Y Cool Contactor Cool 24V Supply 0 Single-stage Heat Pump System Wiring diagrams Reversing Valve Compressor Contactor X Fan Relay Heat/Cool 24V Supply Cool Mode Heat Mode OR WG Rc Rh O B Y X Jumper 2-wire Heat Only System Rc Rh W Heat 24V or Millivolt Supply Heat Relay or Valve X Jumper 1 Wiring diagrams, cont. GRcRhWHeat24VSupplyHeatRelayor ValveXJumper3-wireHeatOnlySystemFan RelayG Rc Rh W Heat 24V Supply Heat Relay or Valve X Jumper 3-wire Heat Only System Fan Relay 3-wire 3-wire3-wire C CCo ooo ool ll O OOn nnl lly yy S SSy yys sst tte eem mm GRcRhYCoolContacterCool 24V SupplyXJumperFan RelayG Rc Rh Y Cool Contacter Cool 24V Supply X Jumper Fan Relay 2 © 2007 Hunter Fan Company ...

Otros modelos de este manual:
Los termostatos - 40170 (714.5 kb)
Los termostatos - 40170 (714.5 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría