Manual de usuario Aube Technologies, modelo 40120

Fabricar: Aube Technologies
Tamaño del archivo: 790.24 kb
Nombre del archivo: 44018.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Set the Set Temperature slider to the desired temperature. 2. The System Switch determines the operating mode of the thermostat. Select Off or Heat. 3. The Fan Switch should normally be located in the Auto position. To run the fan continuously, slide the Fan Switch to the On position. Note: In Auto , The fan will be turned on along with normal operation of your system. In a normal gas or oil furnace, the fan will be turned on by your furnace after its warm-up delay. indicators and adustment 1. The Thermometer indicates the room temperature. 2. The Battery Indicator displays two stages of Weak Battery Warning, indicated by the Battery Indicator flashing once approximately every second. When this warning appears, install two fresh AA alkaline batteries at your earliest convenience. 3. The second warning is the Shut-down Indicator, indicated by the Battery Indicator flashing approximately twice every second. When this warning appears, the thermostat is shut down and will turn your system OFF. Your system will remain shut-off until you install two fresh AA alkaline batteries. SPAN Span Adjust Indicators and Adjustments, cont. Your thermostat is preset to cycle your system off and on at 1oF above and below the Set Temperature. For maximum system efficiency and a sustained comfortable temperature your system should cycle 3 - 5 times per hour. If your system is cycling either too often or not often enough, then use a small Phillips-head screwdriver to turn the Span Adjust left or right to change the cycle time. 1. Remove the thermostat from the wall plate. 2. To make your system run LONGER, turn the Span Adjust clockwise. 3. To make your system run SHORTER, turn the Span Adjust counter clockwise. 4. Reattach the thermostat to the wall plate. Note: The Span range is 0.6oF - 3oF. The Span setting remains the same in both the Heat and Cool modes and can be changed regardless of what position the System Switch is in. 1. My heating or cooling will not turn on or off. 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b. Check the circuit breakers and switches to ensure there is enough power to the system. 1 c. Replace the batteries with fresh AA alkaline batteries. 1 d. If applicable, make sure the furnace blower door is closed properly. ...................................................................................... 2. My system continues to operate when the thermostat is in the off position. 2 a. Replace unit. troubleshooting Is there help on the web? Yes. Visit for more information. .................................................................................... ......... Can’t I just call someone? Sure. Our Technical Support Group is available from 8 am to 5 pm CST. They may be reached toll-free at1-888-830- 1326. wiring diagrams RhWHeat 24V or Millivolt SupplyHeat Relayor Valve2-wire Heat Only System GRhWHeat 24V SupplyHeat Relayor Valve3-wire Heat Only SystemFan Relay © 2007 Hunter Fan Company ...

Otros modelos de este manual:
Los termostatos - 40120 (790.24 kb)
Los termostatos - 40120 (790.24 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría