Resumen del manual


This function could start the heating system as early as 6 hours prior to the programmed time. To enable this function, set the switch E.S. to “ON” at the back of the thermostat. PROGRAMMING Programming the time and day 1-Set the time using the Hour and Min buttons. 2-Set the day using the Day button. Programming the Comfort, Economy and Vacation settings The Comfort , Economy and Vacation settings respectively represent the temperatures that you wish to have during the day , at night or while you are away at work , or while you are away for an extended period . 920-110-003-00-1-A 1/2 1-Press on PGM button to access the programming mode. 2-Press on Day button 3 seconds to select every day of the week. 3-Press on Hour and Min buttons to enter 6:15 AM, Prog. 1 ( ). 4-Press on PGM button to select Prog. 2 ( ) and Hour and Min buttons to enter 8:15 AM. 5-Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM). NOTE: When making modifications, make sure you are in the right program. Temporary or permanent temperature bypass This operation allows you to temporarily modify the room temperature while you are in the Automatic mode. Simply press on or button to select the desired temperature, or the or button to select the Comfort or Econo settings you have programmed.This temperature will be maintained until the beginning of the next programmed schedule. You can also switch to the Vacation setting for a prolonged absence by pressing on and at the same time.The display will show icon. In that case, the derogation is permanent. To return to the normal operating mode, press on Mode button. If you wish to immediately return to the programmed settings, press on Mode button twice. 7Press on PGM button to select Prog. 1 ( ) and Hour and Min buttons to enter 7:30 AM. 8Press on PGM button to select Prog. 2 ( ) and then Clear button to erase it. 9Press on PGM button to select Prog. 3 ( ) and then Clear button to erase it. 10-Press on PGM button to select Prog. 4 ( ) and then Hour and Min buttons to enter 11:00 PM. 11-Press on Mode button to exit this function. a) To program your schedule 1-Press on PGM button to access the programming mode. 2-Press on Day button to select the day to be programmed. You can select all days of the week by pressing on Day button for 3 seconds. 3-Press on PGM button to select program 1, 2, 3 or 4. 4-Press on Hour and Min buttons to program the time. 5-When you have completed your programming, press on Mode button to exit this function. b) To erase a program : Select the program using PGM and Day buttons, and press on Clear button. The time field displays --:-- when the program is inactive. c) Example 1 : Comfort period from 7:00 AM to 10:30 PM Economy period from 10:30 PM to 7:00 AM Identical schedule for all days of the week. 1-Press on PGM button to access the programming mode. 2-Press on Day button 3 seconds to select every day of the week. 3-Press on Hour button to enter 7:00 AM, Prog. 1 ( ). 4-Press on PGM button again to select Prog. 2 ( ), and press on Hour and Min buttons to enter 10:30 PM. 5-Press on Mode button to exit this function. Schedule programming The TH110A-DP-P allows 4 setting changes for each day of the week. There are no pre-set programs.The programs are tailored to perfectly adapt to your life style. The principle is very simple. For each day, enter the time at which you wake up (P1), the time you leave for work (P2), the time you arrive back home (P3) and the time you go to bed (P4). Mode For savings to be obtained, you must lower the temperature for a period of 2 to 3 times the delay required to bring the temperature back to your comfort level. Example : If your system takes one hour to go from your saving temperature level to your comfort temperature Ievel, it is useless to lower the temperature for a period less than 2 to 3 hours. Program 1 2 3 4 Time Wake-up time Leaving time Return time Bed time d) Example 2 : Comfort period: Monday to Friday from 6:15 AM to 8:15 AM and from 5:00 PM to 10:00 PM. Saturday & Sunday from 7:30 AM to 11:00 PM. NOTE: It is faster to program the same schedule for every day and then modify the exception days. CHARACTERISTICS • Model: TH110A-DP-P (240 VAC) • Supply: 240 VAC, 50/60 Hz • Load: 16.67 A maximum (resistive only) • Power: 4000 watts (NI) @ 240 VAC • Approvals: CSA / UL • Display range: 0 to 60 °C (32 to 140 °F) • Setting range: 5 to 30 °C (40 to 85 °F) • Comfort default setting: 20 °C (68 °F) • Econo default setting: 18 °C (64 °F) • Vacation default setting: 10 °C (50 °F) • Storage: -20 to 50 °C (-4 to 120 °F) WARRANTY AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY PROG. 1 PROG. 2 PROG. 3 PROG. 4 6:15 AM 8:15 AM 5 PM 10 PM 6:15 AM 8:15 AM 5 PM 10 PM 6:15 AM 8:15 AM 5 PM 10 PM 6:15 AM 8:15 AM 5 PM 10 PM 6:15 AM 8:15 AM 5 PM 10 PM 7:30 AM ---- 11 PM 7:30 AM ---- 11 PM This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from autho...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría