Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Carrier, modelo TCSNHP01

Fabricar: Carrier
Tamaño del archivo: 274.66 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


3. Press MODE button once. The SET icon will come on. The display now shows Option 01 setting. 4. Use up and down buttons to move between the available Option 01 values of 1 to 9. Factory default is 3. 5. Press MODE button again to return to Option 01. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. OPTION 02 - --CLEAN FILTER TIMER This option selects the number of hours of blower operation (heating, cooling, or fan) before SERVICE FILTER icon is displayed. With OF selected, the icon will never come on, disabling this feature. Time selection can be from 400 to 3600 hours by selecting numbers 1 through 9. (Time is 400 X number selected.) Factory default is 2 (800 hours). Recommended selections are: disposable filter 800 hr, media filter 1200 to 1600 hr, or electronic air cleaner 1600 to 2400 hr of blower operation. To Adjust: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 02. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 02 setting. 4. Use up and down buttons to move between the available Option 02 values of OF and 1 through 9. Factory default is 2. 5. Press MODE button again to return to Option 02. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. OPTION 03 - --FAHRENHEIT/CELSIUS SELECTION This option selects Fahrenheit or Celsius operation. To Select: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 03. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 03 setting. 4. Use up and down buttons to move between the available Option 03 choices of F (Fahrenheit) or C (Celsius). Factory default is F. 5. Press MODE button again to return to Option 03. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. OPTION 04 - --G (FAN) ON WITH W OUTPUT This selection determines whether the G (fan) output is to be ON or OFF when any W (furnace or strip heat) output is ON. Most furnaces and fan coils manage their own blowers and do not require a separate G signal. For these applications, select OFF. Some auxiliary heaters require a separate G signal to turn on the blower. In this case, select On. Factory default is OF (off). To Select: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 04. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 04 setting. 4. Use up and down buttons to move between available Option 04 choices of ON or OF. Factory default is OF. 5. Press MODE button again to return to Option 04. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. OPTION 05 - --HP / AC CONFIGURATION This configuration is available on HP models only. Selecting AC allows the installer to use a HP thermostat in an air conditioner application. To Select: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 05. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 05 setting. 4. Use up and down buttons to move between available Option 05 choices of AC or HP. Factory default is HP. 5. Press MODE button again to return to Option 05. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. OPTION 07 - --ZONING ON/OFF CONFIGURATION This selection enables or defeats cycle timer, the staging timer, and the compressor timeguard. (See Operational Information for details.) These timers MUST be enabled (zoning OFF) for normal operation and disabled (zoning ON) for zoning applications. In zoning applications, the zone control center performs these timing functions. Factory default is OF. To Select: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 07. The SET icon should be off. TCSN 3 TCSNTCSN 3. Press MODE button once. The SET icon will come on. The display now shows Option 07 setting. 4. Use up and down buttons to move between available Option 07 choices of ON or OF. Factory default is OF. 5. Press MODE button again to return to Option 07. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. OPTION 10 - --O (REVERSING VALVE) ON WITH HEAT OR COOL SELECTION This selection is only available on HP model thermostats when HP is selected via Option 05. This selection determines whether the reversing valve is energized in the heating or cooling mode. Factory default is C, energized in cooling. Use up and down buttons to ch...

Otros modelos de este manual:
Los termostatos - TCSNAC01 (274.66 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría