Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Honeywell, modelo MX-50

Fabricar: Honeywell
Tamaño del archivo: 1.2 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


MEM Full Memory The number of results stored in memory has reached the upper limit. fUl Clear the data to store the new results. Refer to "11. Data Memory Function". Ht err t-Up e -e Cal e RESET -Cal e MS-70 / MX-50 / MF-50 / ML-50 67 15. Specifications MS-70 MX-50 MF-50 ML-50 Measurement method 400 W halogen lamp, thermogravimetric analysis Drying temperaturerange at sample pan ( Increments) 30°C to 200°C (1°C ) 50°C to 200°C (1°C ) Heating pattern Standard drying, Ramp drying, Step drying, Quick drying Standard drying, Quick drying Temperature calibration By Accessory AX-MX-43 - Sample weight range 0.1 g to 71 g 0.1 g to 51 g Accuracy: Repeatability of measurement, (Standard deviation) Moisture content 1 over 5 g sample 0.01 % 0.02 % 0.05 % 0.1 % over 1 g sample 0.05 % 0.1 % 0.2 % 0.5 % Weighing mode 0.0005 g 0.001 g 0.002 g 0.005 g Minimum reading Moisture content 0.001 %, 0.01 %, 0.1 % 0.01 %, 0.1 % 0.05%, 0.1 %, 1 % 0.1%, 1 % Weighing mode 0.0001 g 0.001g 0.002g 0.002g Measurement programs Sample weight and termination value is automatically set with ACCURACY and % display. When drying rate reaches the termination value, measurement is automatically completed. ( 2)Standard mode Standard drying, Ramp drying, Step drying Standard drying Sample weight and termination value is automatically set with ACCURACY and % display. When drying rate reaches the termination value, measurement is automatically completed. ( 2)Quick mode Quick drying When drying rate is less than preset termination value, measurement is automatically completed. ( 2)Automatic mode Standard drying, Ramp drying, Step drying Standard drying After heating for the preset drying time, measurement is automatically stopped. (1min. to 480 min.)Timer mode Standard drying, Ramp drying, Step drying Standard drying When pressing the key at any time, measurement is stopped andthe result is decided. Analysis mode Manual mode Standard drying, Ramp drying, Step drying Standard drying Moisture content (Wet-base) Moisture content (Dry-base, Atro) Dry content Ratio Measurement unit Weight (g) Number of memory 20 sets 10 sets 5 sets Data memory function 100 results 50 results 30 results Communication function RS-232C serial interface Operation environment 5°C to 40°C (41°F to 104°F), 85%RH or less (no condensation) Sample pan .85 mm 15. Specifications MS-70 MX-50 MF-50 ML-50 Measurement method 400 W halogen lamp, thermogravimetric analysis Drying temperaturerange at sample pan ( Increments) 30°C to 200°C (1°C ) 50°C to 200°C (1°C ) Heating pattern Standard drying, Ramp drying, Step drying, Quick drying Standard drying, Quick drying Temperature calibration By Accessory AX-MX-43 - Sample weight range 0.1 g to 71 g 0.1 g to 51 g Accuracy: Repeatability of measurement, (Standard deviation) Moisture content 1 over 5 g sample 0.01 % 0.02 % 0.05 % 0.1 % over 1 g sample 0.05 % 0.1 % 0.2 % 0.5 % Weighing mode 0.0005 g 0.001 g 0.002 g 0.005 g Minimum reading Moisture content 0.001 %, 0.01 %, 0.1 % 0.01 %, 0.1 % 0.05%, 0.1 %, 1 % 0.1%, 1 % Weighing mode 0.0001 g 0.001g 0.002g 0.002g Measurement programs Sample weight and termination value is automatically set with ACCURACY and % display. When drying rate reaches the termination value, measurement is automatically completed. ( 2)Standard mode Standard drying, Ramp drying, Step drying Standard drying Sample weight and termination value is automatically set with ACCURACY and % display. When drying rate reaches the termination value, measurement is automatically completed. ( 2)Quick mode Quick drying When drying rate is less than preset termination value, measurement is automatically completed. ( 2)Automatic mode Standard drying, Ramp drying, Step drying Standard drying After heating for the preset drying time, measurement is automatically stopped. (1min. to 480 min.)Timer mode Standard drying, Ramp drying, Step drying Standard drying When pressing the key at any time, measurement is stopped andthe result is decided. Analysis mode Manual mode Standard drying, Ramp drying, Step drying Standard drying Moisture content (Wet-base) Moisture content (Dry-base, Atro) Dry content Ratio Measurement unit Weight (g) Number of memory 20 sets 10 sets 5 sets Data memory function 100 results 50 results 30 results Communication function RS-232C serial interface Operation environment 5°C to 40°C (41°F to 104°F), 85%RH or less (no condensation) Sample pan .85 mm 1: After preheating the analyzer, the data can be obtained with approximately 5 g test sample (Sodium tartrate dihydrate) in standard mode (MID.), standard drying, 160 °C 2: When change of moisture content per one minute reaches the preset termination value, the measurement is completed. 68 MS-70 / MX-50 / MF-50 / ML-50 MS-70 / MX-50 / MF-50 / ML-50 69 MS-70 MX-50 MF-50 ML-50 Power source, Maximum current (r.m.s), Maximum consumption AC100V to 120V 3A or AC200V to 240V 1.5A, 50Hz or 60Hz, Approximately 400W 3 External dimensions 215(W) x 320(D) x 173(H)mm, 8.46(W) x 12.60(D) x 6.81(...

Otros modelos de este manual:
Los termostatos - MF-50 (1.2 mb)
Los termostatos - ML-50 (1.2 mb)
Los termostatos - MF-50 (1.2 mb)
Los termostatos - MS-70 (1.2 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría