Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario Honeywell, modelo CHRONOTHERM IV DELUXE T8624D

Fabricar: Honeywell
Tamaño del archivo: 799.94 kb
Nombre del archivo: 6609d247-1193-415b-b8b5-0b5d8c0105d2.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


FEATURES B Full seven-day program capability; different schedules and temperature setpoints may be selected for everyday to match the homeowner’s flexible schedule. B Copy key makes programming easier and faster for the installer and homeowner. B Daylight Savings Time (DST) key for quick change in and out of Daylight Savings Time. B Models available with programmable fan operation for added homeowner comfort. B Easy temporary temperature setpoint changes for current period, vacation hold (1 to 255 days) or indefinite hold adds to the homeowner comfort and energy savings. B Most frequently used keys are located by the Liquid Crystal Display (LCD) for quick and easy access to information. B Attractive styling complements any decor to the homeowner’s delight. B Back lighting the large display makes the LCD very easy to read. PRODUCT DATA B Models available with outdoor temperature sensor capability for homeowner convenience. The sensor is also more accurate than a thermometer. B Configurable features allows one model to be used to replace many different models (less inventory, no longer need to carry separate models to get these features). — °F or °C temperature display; — automatic or manual changeover; — electric or conventional heat fan operation; — adjustable heating cycle rate. B Minimum off time for cooling compressors and heat pumps protects the equipment and extends the equipment life. B Easy installation, setup and system test saves installer time and increases productivity. B System test simplifies troubleshooting and saves time by overriding the time delays. B Adaptive Intelligent Recovery® control brings the room temperature to temperature setpoint at the programmed time, maximizing comfort and energy savings. B Setpoints are permanently held in memory (no batteries used) and retained during power outages for increased installer and homeowner convenience. B Universal Versaguard™ Thermostat guards available for added security. Contents General ............................................................................... 1 Features .............................................................................. 1 Specifications ...................................................................... 2 Ordering Information ........................................................... 2 Installation ........................................................................... 3 Wiring .................................................................................. 4 Settings ............................................................................... 6 Installer Setup ..................................................................... 7 Installer System Test ........................................................... 10 Programming....................................................................... 12 Operation ............................................................................ 16 Troubleshooting Guide ........................................................ 18 Cross Reference ................................................................. 19 Wiring Diagram ................................................................... 20 ® U.S. Registered Trademark 68-0166-1 Copyright © 1997 Honeywell Inc. • All Rights Reserved T8624D CHRONOTHERMT8624D CHRONOTHERM IV DELUXE PROGRAMMABLE THERMOSTAT SPECIFICATIONS Important The specifications given in this publication do not include normal manufacturing tolerances.Therefore, this unit might not exactly match the listed specifications.This product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. Thermostat Model T8624D Thermostats provide features listed in Table 1. Table 1. Thermostat Features. System Fan Changeover Selection Selection Comments Automatic Heat-OffOn- Auto System and fan Cool-Auto selections are done by keyboard. Electrical Rating (Nominal Range): 24 Vac, 50/60 Hz. 20 to 30 Vac, 50/60 Hz. Batteries: No batteries required. Loss of Power: The thermostat will maintain programmed times and temperatures for the life of the product. The clock and day information is retained for a minimum of thirty minutes. System Current Load Ratings: 6 VA maximum at 30 Vac, 50/60 Hz. Output Relay Draw: See Table 2. Table 2. Maximum Amps at 30 Vac. Relay Running (A) Inrush (A) Fan 0.5 2.5 Heat (all stages) 1.5 3.5 Cool (all stages) 1.5 7.5 Temperature: Ratings: Operating Ambient: 40°F to 110°F (4°C to 43°C). Shipping: -30°F to +150°F (-34°C to +65°C). Display Accuracy: ±1°F (±0.5°C). Setpoint: Range: Heating: 40°F to 90°F (7°C to 31°C) Cooling: 48°F to 99°F (9°C to 37°C). Differential: 3°F (1.5°C). Default Settings: see Table 3. Table 3. Default Setpoints. Period Time Heat Setpoint Cool Setpoint Fan Setting Wake 6:00 AM 70°F (21°C) 78°F (25.5°C) Auto Leave 8:00 AM 62°F (16.5°C) 85°F (29.5°C) Auto Return 6:00 PM 70°F (21°C) 78°F (25.5°C) Auto Sleep 10:00 PM...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría