Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario GE, modelo RAK148P1

Fabricar: GE
Tamaño del archivo: 558.98 kb
Nombre del archivo: 2ee75b2a-1a5d-4c16-bac3-46a65de149a3.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


. . . . . . . . . . .8–9 Important Safety Information . . . .2 Installation Instructions . . . . . . . . 4–7 Introduction Overview . . . . . . . . . . . .3 Low Battery/Combination Failure Indicators . . . . . . . . . . . .18–19 Operating Functions . . . . . . . . . . . .13 Operation . . . . . . . . . . . . . . . . . . . . . . .10 Programming . . . . . . . . . . . . . . .15–17 Setting the Time and Day of the Week . . . . . . . . . . .14 Specifications . . . . . . . . . . . . . . . . . . . . .2 Starting the Thermostat . . . . . . . . .11 Testing the Thermostat . . . . . .11–12 Troubleshooting Tips . . . . . . . . . . . .20 Warranty . . . . . . . . . . . . . . . . . . . . . . . .24 As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. LIA219-1 49-7544-1 11-08 JR Important safety information. WARNING! Always turn off power at the main power supply before installing, cleaning or removing the thermostat. • This thermostat is for 24 VAC applications only. Do not use on voltages over 30 VAC. • All wiring must conform to local and national electrical and building codes. • Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage your A/C system and cause personal injuries. • Use this thermostat only as described in this manual. Specifications. Electrical rating: • 24 VAC (18–30 VAC) • 1 amp maximum per terminal • DC Power: 3.0 VDC (2 “AA” batteries included) • 4 amp maximum total load Operating temperature range: 40°F–99°F (4°C–37°C) Temperature set range: 60°F–85°F (15°C–29°C) Accuracy: ± 1°F (± 0.5°C) System configurations: 2-stage heat (RAK148P1 heat pump/resistance heat); 1-stage heat (RAK164P1 resistance heat); 1-stage cool Timing: Anti-short cycle: 3 minutes (minimum compressor run time/off time). Note: There may be a 3 minute minimum fan run time/off time on some models. Terminations: R, C, W, Y, G, B (RAK148P1); R, C, W, Y, G (RAK164P1) INTRODUCTION OVERVIEW PARTS DIAGRAM Reset Switch Mode Switch Hold Switch Display Function Switch Fan Auto/On Switch Toggle Up/Down Switches THERMOSTAT CONTROL Display Toggle Up/Down Buttons Function Switch Mode/Hold Buttons Fan Auto/On Switch Two “AA” Batteries INSTALLATION INSTRUCTIONS ELECTRICAL SHOCK HAZARD—Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat. PACKAGE CONTENTS/TOOLS REQUIRED Package includes: Thermostat on base, thermostat cover, 2 “AA” batteries, wiring labels, screws and wall anchors. Tools needed: Drill with 3/16. bit, hammer, screwdriver. TO REMOVE EXISTING THERMOSTAT 1. Turn off power to heating and cooling system by removing the fuse or switching off the appropriate circuit breaker. 2. Remove cover of old thermostat. This should expose the wires. 3. Label the existing wires with the enclosed wire labels before removing wires. 4. After labeling wires, remove wires from wire terminals. 5. Remove existing thermostat base from wall. 6. Refer to the following section for instructions on how to install this thermostat. TO INSTALL THERMOSTAT IMPORTANT: Thermostat installation must conform to local and national building and electrical codes and ordinances. Note: Mount the thermostat about five feet above the floor. Do not mount the thermostat on an outside wall, in direct sunlight, behind a door or in an area affected by a vent or duct. TO INSTALL THERMOSTAT (cont.) 1. Turn off power to the heating and cooling system by removing the fuse or switching off the appropriate circuit breaker. Move the Function switch to Off. 2. To remove cover, insert and twist a coin or screwdriver in the slots on the sides of the thermostat. 3. Put thermostat base against the wall where you plan to mount it. Make sure wires will feed through the wire opening in the base of the thermostat. 4. Mark the placement of the mounting holes. 5. Set thermostat base and cover away from working area. 6. Using a 3/16. drill bit, drill holes in the locations you have marked for mounting. 7. Use a hammer to tap supplied anchors in mounting holes. 8. Align thermostat base with mounting holes and feed the control wires through the wire opening. 9. Use supplied screws to mount thermostat base to wall. 10. Insert stripped, labeled wires in matching wire terminals. See “Wiring Diagrams” section of this manual. CAUTION! Make sure exposed portion of wires does not touch other wires. 11. Tighten screws on terminal block. Gently tug wire to be sure of proper connection. Double check that each wire is connected to the proper terminal. 12. Insert two “AA” batteries into battery holder. Verify that they are oriented as shown on battery holder. 13. Seal hole for wires behind thermostat with non-flammable insulation or putty, or use a wall plate obtainable from a local hardware or home building store. INSTALLATION INSTRUCTIONS TO INSTALL THERMOSTAT (cont.) 14. Replace cover on thermostat by sna...

Otros modelos de este manual:
Los termostatos - RAK148P1 (558.98 kb)
Los termostatos - RAK164P1 (558.98 kb)
Los termostatos - RAK164P1 (558.98 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría