Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Chromalox, modelo PK477

Fabricar: Chromalox
Tamaño del archivo: 149.6 kb
Nombre del archivo: IM-PK477.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Because they do not fail safe, they should not be used for temperature limiting duty. WARNING: Users should install adequate back-up controls and safety devices with their electric heating equipment. Where the consequences of failure may be severe, back-up controls are essential. Although the safety of the installation is the responsibility of the user, Chromalox will be glad to make equipment recommendations. WARNING: Not for use in hazardous environments as described in the National Electrical Code. Failure to comply can result in explosion or fire. Thermostat Location 1. Mount in any standard electrical outlet box. Use of extra deep box (3” x 2” x 3'/2”) makes for easier wiring. 2. Locate outlet box about 5’ above floor on inside wall. 3. Box location should be representative of the area to be controlled. Avoid locations that are subject to drafts or false external heat (such as solar radiation, direct heat from heaters, etc.). Insure that the wall selected is capped to prevent drafts within the wall. © 2010 Chromalox, Inc. INSTALLATION 1. Cut lead wires protruding from outlet box approximately 4” from wall surface and strip end insulation '/2”. 2. Always test the heater circuit for electrical shorts before connecting the thermostat. 3. Remove thermostat knob and front cover. 4. Using wire-nuts or other local code approved devices, connect load and line wires to appropriate color coded thermostat wires. (See wiring diagrams below.) 5. Mount the thermostat to the outlet box using the screws provided. Take care not to push or damage the bimetal sensing element during installation. 6. Replace the thermostat front cover and knob. WARNING: Any knob temperature setting below 50°F may result in freezing. WIRING WARNING: Hazard of Electric Shock. Disconnect all power before wiring or servicing this control. Electric wiring to heater must be installed in accordance with National Electrical Code and with local codes. WARNING: Use copper conductors only. Connect wires according to wiring diagrams (Figures 1 and 2). Note: Electrical connections should be made with generous loops of wire — approximately 6” per lead. Note: If load amperage or voltage rating exceeds switch rating, a contactor must be used. Figure 1: Figure 2: L2 ■ WT-121 Single Line Break Thermostat with Heat Anticipation Red Anticipator V\AAA White Black Heater Load L-----pwwv- WT-122 Double Line Break Thermostat with Heat Anticipation -T— L2 - Red Red 0n/0ff Switch Black Anticipator -^vw^- Temperature Control Switch Black Heater Load -U/WVWV—' Note: 1. Connect anticipator lead (white) in parallel with heater. 2. Thermostat performance will be degraded if anticipator connection is omitted. Note: 1. Suitable for control of one heating load only. 2. No separate connection required for heat anticipation. 3. Temperature control switch is located on right hand side when thermostat is viewed from the rear. Limited Warranty: Please refer to the Chromalox limited warranty applicable to this product at Chromalox* PRECISION HEAT AND CONTROL 1347 HEIL QUAKER BLVD., LAVERGNE, TN 37086 Phone: (615) 793-3900 www.chromalox.com...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría