Manual de usuario Lumiscope, modelo 1131

Fabricar: Lumiscope
Tamaño del archivo: 1.08 mb
Nombre del archivo: 022f15da-d169-43ea-87de-dc7f09b93cc8.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Latest memory will be recalled first. The calculated average will be applied to a maximum of the last 3 memories. 10 Clearing Values from Memory 1. Press the User-Switching key to select the memory zone 1 or memory zone 2. 2. Continue to press and hold the “M” key for approximately 5 seconds, and the data in the pre- designated memory zone will be erased automatically. Note : The data in both memory zones (zone 1 and zone 2) will be erased if any of the batteries are removed, or if the AC adapter is disconnected from the unit or unplugged from the outlet. (It is suggested that users record their data on the Blood Pressure Log before removing or replacing batteries.) Press “M” Key for 5 seconds to clear all memories 11 Time Adjustment 1. To adjust the date/ time in the monitor, press the key . The display will show a blinking number showing the month. 2. Change the month by pressing the “ ” Key. Each press will increase the number by one in a cycling manner. Press the Key. again to confirm the entry, and the screen will show a blinking number representing the date. 3. Change the date, the hour, and the minute as described in Step 2 above, using the “ ” Key to change and the Set Key to confirm the entries. 4. A “0” will reappear as the Blood Pressure Monitor is ready for measurement again. Press the Set-key blinking month increasing month confirm the entry 12 Helpful Tips Here are a few helpful tips to help you obtain more accurate readings: • Do not measure your blood pressure immediately after consuming a large meal. Wait at least one hour after eating to take a measurement. • Do not smoke or drink alcohol before measuring your blood pressure. • You should not be physically tired or exhausted while taking a measurement. • It is important that you relax during measurement. Take 15-minute rest before a reading. • Do not take measurements if you are under stress or under tension. • Take your blood pressure at normal body temperature. If you are feeling cold or hot, wait a while before taking a measurement. • If the monitor is stored at very low temperature (near freezing), have it placed at a warm location for at least one hour before using it. • Wait about 5 minutes in between consecutive measurements. 13 Troubleshooting If any abnormality should arise during use, please check the following points. Symptom No display when the ON/OFF/START key is pressed EE mark shown on display or the blood pressure value is displayed excessively low (high) Check Point Have the batteries run down? Have the batteries’ polarities been positioned incorrectly? Is the cuff placed correctly? Did you talk or move during measurement? Did you vigorously shake the cuff during measurement? Correction Replace them with four new batteries or use AC Adapter. Re-insert the batteries in the correct positions. Wrap the cuff properly so that it is positioned correctly. Measure again quietly. Note: If the unit still does not work, return it to your dealer or contact our repair department. Under no circumstance should you disassemble and attempt to repair the unit by yourself. 14 Cautionary Notes: 1. The unit contains high-precision assemblies. Therefore, avoid extreme temperatures, humidity, and direct sunlight. Avoid dropping or strongly shocking the main unit, and protect it from dust. 2. Clean the blood pressure monitor body and the cuff carefully with a slightly damp, soft cloth. Do not press. Do not wash the cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner. 3. Leaky batteries can damage the unit. Remove the batteries when the unit is not used for a long time. 4. The unit should not be operated by children so to avoid hazardous situations. 5. If the unit is stored near freezing, allow it to acclimate at room temperature before use. 6. Your Lumiscope Model 1131 is not field serviceable. You should not use any tool to open the device nor should you attempt to adjust anything inside the device. If you have any problems, please contact the store or the doctor from whom you purchased Lumiscope Model 1131 or contact the Lumiscope Repair Department at 1-800-672-8293. 7. For users diagnosed with common arrhythmia (atrial or ventricular premature beats or atrial fibrillation), diabetes, poor circulation of blood, kidney problems, or for users who have suffered from stroke, the device might not be suitable for use. 8. Do not use on unconscious patients. 15 Specifications: Measurement Method : Oscillometric Measurement Range : Pressure: 20~280mmHg; Pulse: 40~180 beats/ minute Pressure Sensor : Semi conductor Accuracy : Pressure: ± 3mmHg; Pulse: ± 5% of reading Inflation : Pump Driven Deflation : Automatic Pressure Release Valve Memory capacity : 50 memories for each memory zone Auto-shut-off : 1 minute after last button operation Operation Environment : Temperature: 5 °C ~ 45 °C (41 °F~113 °F); Humidity: 40 ~ 85% Storage Environment : Temperature: -10 °C ~ 60 °C (14 °F~140 °F ); Humidity: 10 ~ 95% Power So...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría