Iniciar sesión:
Votos - 3, Puntuación media: 3.3 ( )

Manual de usuario Panasonic, modelo EW3003

Fabricar: Panasonic
Tamaño del archivo: 745.11 kb
Nombre del archivo: EW3003.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


1. Press the Memory/Recall button. • The average readings of all recorded measurements are displayed. • The mark will be displayed (Fig. 10-a). • When, for example, readings from 21 measurements (After approx. have been saved the average of the readings from 21 one second.) measurements will be displayed. Fig. 10-b 2. Press the Memory/Recall button to display readings starting with from the most recent measurement. • Each time the Memory/Recall button is pressed readings are displayed in order of the most recent measurement (Fig. 10-b). • No readings will be displayed when there are none in the memory. 3. Press the On/Off and Start button to switch off the unit. If you forget to switch off the unit it will do so automatically after approx. 30 seconds. Deleting all data stored in memory (1) Recall stored data using the Memory/Recall button. (2) Press the Memory/Recall button again and hold it (for approx. 3 seconds) until all readings are deleted. NOTE: Readings from individual measurements cannot be deleted. (3) When data has been deleted the mark and will be displayed on the screen. Care and Maintenance Troubleshooting Troubleshooting 1. Use a dry, soft cloth to clean the device. If desired, use a cloth lightly dampened with tap water and a mild detergent to clean the device. DO NOT use alcohol, benzine, thinner or other harsh chemicals to clean the device or cuff. 2. When the unit will not be used for a long time (30 days or more), be sure to remove the batteries. Otherwise, the batteries may leak and damage the unit. NOTE: When the batteries are removed, the date, time, and measurement record are erased. Set the date and time again the next time you use the unit. Display Status before error Check points Pressurization to above Check whether The blinks on 280 mmHg was performed. (Re-pressurization was performed several times.) measurements are being taken correctly and whether you are assuming the correct posture. Make sure the display the unit is on the palm side of the wrist. (See pages 9-10.)Pressure decreased suddenly and appeared in the display. mark only blinks a few times, or not at all. Check whether the pressure cuff is attached to your wrist correctly. Make sure the unit is on the palm side of the wrist. (See page 9.) Cuff does not inflate. Storing the Monitor 1. Fold the pressure cuff as indicated. (Fig. 11-a) 2. Put the blood pressure monitor in the storage case. (Fig. 11-b) • Be sure not to pinch the pressure cuff or 2cm gauge when closing the case. Fig. 11-a Fig. 11-b If the 2cm gauge is attached, straighten it out. 17 18 If the unit still appears to provide unusual or erroneous readings, consult your physician. If the unit does not appear to be functioning properly, contact Panasonic at 1-800-338-0552. Specifications Symptom Possible cause The systolic pressure value or diastolic pressure value is high. • The hand with the cuff was held too low and not at heart level. (See page 9) • The cuff was not attached properly. (See page 9.) • You moved your hand or body or you spoke during measurement. (See page 9.) The systolic pressure value or diastolic pressure value is low. • The hand with the cuff was held too high and not at heart level. (See page 9.) • You moved your hand or body or you spoke during measurement. (See page 9.) The measured values differ significantly. • Your posture was not the same for all measurements, or measurements were taken without sufficient time in between. Always wait approximately 5 minutes before taking another reading, and above all, relax. The measured value differs from that measured by the doctor. The measured value is different for each measurement. • Blood pressure varies in response to minute changes in your mental state, such as your reaction to your doctor taking the measurement. One way to check this is to bring the unit to your doctor’s office and directly compare the readings taken by your physician. • Relax for at least 5 minutes and then take another measurement. Varying sounds and pressurization speeds occur during inflation of the cuff. • Changes in operating sounds and pressurization speeds are normal and occur due to the fact that measurements are being made as the cuff is being inflated. The measured value obtained is different from that measured at the upper arm. • For persons with certain circulation problems, there may be substantial differences in blood pressure values measured at the upper arm versus at the wrist. Method of measurement: Oscillometric System Display: Digital LCD Measuring range: Blood pressure: 0 - 280 mmHg Pulse rate: 30 - 160 pulse/min. Measurement accuracy: Pressure: ±3 mmHg Pulse rate: ±5% Power source: Two 1.5-volt alkaline (AAA/LR03) batteries Operating environment: 10°C to 40°C (50°F to 104°F) 30% to 85% RH Storage environment: -20°C to 60°C (-4°F to 140°F) 10% to 95% RH Wrist circumference measurement range: 12.5 to 22.0 cm (5" to 8-3/4") Dimensions (H#W#D): 58.0#89.0#33.0 mm (2-5/16"#3-1/2"#1-5/16") Weight: 95 g (3....


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría