Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Health O Meter, modelo 7632

Fabricar: Health O Meter
Tamaño del archivo: 1.08 mb
Nombre del archivo: f051fea1-369f-4414-b1fc-d99939951c85.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


There is a significant correlation of high blood pressure with cardiovascular disease. This correlation has made measuring blood pressure a necessity for those individuals identified with high blood pressure, placing them into a high risk category pertaining to cardiovascular disease. Also, as a person ages, one’s blood pressure can change over time, thus it makes good “health sense” to monitor your blood pressure on a regular basis. Blood Pressure Standard The World Health Organization (WHO) has developed a blood pressure standard, according to which areas of low and high-risk blood pressure are identified. This standard, however, is a general guideline as individual’s blood pressure varies among different people and different age groups, etc. Systolic over 160 Hypertension Diastolic over 100 95 Systolic 140 ~159 Borderline Diastolic 90 ~ 94 90 Hypotension Normal Systolic Systolic under 139 under 99 Diastolic under 89 100 140 160 Systolic (mmHg) > It is important that you consult with your physician Your physician can tell you your optimal blood pressure range. Blood Pressure Fluctuation Diastolic (mmHg)> Blood pressure fluctuates all the Your blood pressure will change the course of the month, week throughout the day. It is also influenced by seasonal and temperature 7 Fluctuation Within a Day (Case: Male, 35 Years Old) Wake Up Arrive Office Discussion on the Telephone Argument in a Meeting Leave Office 6 PM 12 AM12 PM6 AM 50 100 150 200 mmHg Dinner /Sleep Systolic Pressure Diastolic Pressure Replace the bateries if: 1. The weak battery mark appears in the display. 2. Nothing appears in the display when the power is switched on. As the supplied batteries are for test only, they may discharge earlier than batteries you buy in stores. Replace the batteries in pairs. Remove batteries when unit is not in use for extended periods of time. Note: Discard used batteries as directed by your local, environmental codes. Setting the Time 1. To set/adjust the date and time in the monitor, press the “ Set” Button located on the top surface of the monitor. The display will show a blinking number showing the month. 2. Change the month by pressing the button. Each press of this button will increase the number by one in a cycling manner. Press the Set Button again to confirm the entry, and the screen will show a blinking number representing the number of the day in the month. 3. Change the date, the hour and the minutes as described using the button to change and the button to confirm the entries. 4. A “ 0” will reappear as the Blood Pressure Monitor is ready Press the Set Button Month Position Will Blink Press To Select Month Press To Confirm Selection 10 Proper Posture During Measurement 1. Place your elbow on a table so that the cuff is at the same level as your heart as shown in Figure A. Note: Your heart is located slightly below your armpit and a bit to the left of the middle of your chest. Relax your entire body, especially the area between your elbow and fingers. FIGURE A FIGURE B 2. If the cuff is not at the same level as your heart or if you can not keep your arm completely still throughout the reading, use a soft object such as a folded support your arm as shown in Figure B. Do not allow hard objects to come contact with the wrist cuff. 3. Turn your palm upwards. 4. Sit upright in a chair, and take 5-6 deep, relaxing breaths. 5. Avoid leaning back while the measurement is being Figure C. FIGURE C 12 Tomando 1. Presione el User Selection” para seleccionar o el Area de Memoria se almacenara en el OR 2. Coloque el brazalete en la muneca. Presione . Todos los digitos se iluminaran, verificando las El procedimiento de verificacion se completara despues 3. Despues que todos los simbolos hayan aparecido, la pantalla mostrara un “0” parpadeando. El monitor esta “ Listo para Medir” e inflara automaticamente el brazalete para comenzar la medicion. Este monitor se re-inflara automaticamente a aproximadamente a 220mmHg si el sistema detectara que su cuerpo necesita una presion mayor para medir su presion arterial. 13 4. When the measurement is completed, systolic, diastolic, and pulse will be shown simultaneously and be saved automatically into the memory. The measurement is then automatically stored into the pre-designated memory zone. The last 50 measurement readings will be saved into each memory. Note: 1. This monitor automatically switches off approximately 1 minute after the last button operation. 2. To interrupt the measurement, simply press any key. The cuff will deflate immediately after a key is pressed. 3. During the measurement, do not talk or move your arm or hand muscles. Recalling Values from Memory 1. The monitor has two memory zones (1 and 2). Each zone can store up to 50 measurements. 2. To recall blood pressure readings use the “ User-Selection” button to select the appropriate Memory Zone (1 or 2) from which Once the proper zone M” button. The memory values 14 T roubleshooting If a problem should arise d...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría