Because hypertension affects nearly one in three Americans1, it is vitally important to have a reliable instrument to help accurately diagnose this condition. Accurate Clinically Validated HEM-907XL with wall mount option Gold Standard Accuracy F Pressure; within ± 3mmHg or 2% F Pulse rate; within ± 5% of reading F Utilized in large scale national clinical trials F ACCORD2 and SANDS3 Validated According to Internationally Accepted Protocols F Association for the Advancement of Medical Instrumentation (AAMI) F British Hypertension Society (BHS) F European Society of Hypertension-International Protocol (ESH-IP) HEM-907XL Versatility Healthcare Professionals Expect The HEM-907XL Professional Blood Pressure Monitor provides unique features to meet your individual patient needs giving you the flexibility to efficiently customize your diagnostic approach. Versatile Easy to Use 4 Cuffs Included F Cuff sizes covering a range of 17-50 cm (7” to 20”) to accommodate most users F 4 cuffs included with the unit (small, medium, large, extra large) F Enables accurate readings on virtually all patients Ease of Use F One button operation F Battery or AC adapter F Large and easy to read display F Automatic-off (after 5 minutes of inactivity) IntelliSense® Technology F Uses IntelliSense® technology to automatically determine the correct amount of pressure, resulting in a faster and more comfortable blood pressure measurement for your patients Irregular Pulse Indicator F Indicates a difference in rhythm that is more than 25% slower or faster from the average F Displays the number of irregular pulse waves F Helps identify changes in heart rate, rhythm, or pulse which may be caused by heart disease or other serious health issues3 3 Modes of Operation F Single Mode takes one-time measurement automatically F Average Mode takes 2 or 3 readings and calculates the average automatically and provides the patient’s most accurate measurement F Auscultation (Manual) Mode enables the use of auscultation technique (using a stethoscope) with added benefits of automatic inflation/deflation with digital display 5 Year Limited Warranty The most frequent error in measuring blood pressure in the outpatient clinic is “miscuffing,” with undercuffing large arms being the major problem4 Small, 17-22 cm Medium, 22-32 cm Large, 32-42 cm Extra Large, 42-50 cm HEM-907XL Accessories: Product Specifications HEM-907-CS19 Cuff and Bladder Set, Small, 17-22 cm circumference HEM-907-CR19 Cuff and Bladder Set, Medium, 22-32 cm circumference HEM-907-CL19 Cuff and Bladder Set, Large, 32-42 cm circumference HEM-907-CX19 Cuff and Bladder Set, Extra Large, 42-50 cm circumference with integrated air tube HEM-TUBE-130 Air Tube, 1.3 m Working Length for small, medium, and large cuffs HEM-907-STAND Stand HEM-907-WKIT Wall Mounting Kit HEM-907-PKIT Pole Mounting Kit HEM-907-PBAT Battery Pack HEM-ADPT-907 AC Adapter Name: OMRON Digital Automatic Blood Pressure Monitor Model: HEM-907XL Display: Digital display Measurement: Oscillometric method Measurement Range: Pressure; 0 to 299 mmHg Pulse rate; 30 to 199 beats/min Accuracy: Pressure; Within ±3 mmHg or 2% Pulse rate; Within ±5% of reading Inflation: Automatic inflation with pumping Deflation: Automatic deflation by electromagnetic control valve Air Release: Automatic rapid air release by electromagnetic control valve Pressure Detection: Electrostatic capacity semi-conductor pressure sensor Power supply: AC adapter (120 VAC, 60 Hz, 13 VA) or (120VAC, 50/60Hz, 0.2A) Battery pack (4.8 VDC, 6W) Electric Shock Protection Method: Class II B type Operating Temperature 50°F to 104°F (10 to 40°C), 30 to 85% RH, IPX 0 Ratingand Humidity: Weight of Main Unit: Approx. 32 oz (910 g) External Dimensions: Approx.5 1/2” (W) x 8”(H) x 5 1/6”(D) 139 (W) x 203 (H) x 131 (D) mm Complies with: IEC 60601-1:1998+A1:1991+A2:1995 General requirements for safety IEC 60601-1-2:1993 Electromagnetic compatibility - Requirements and tests AAMI SP10:1992 Manual, Electronic or Automated Sphygmomanometers Package Contents: Blood Pressure Monitor, Cuffs (Extra Large, Large, Medium, and Small) and Bladder Set, 1.3m Air Tube, AC Adapter, and Battery Pack HEM-907XL with stand option 1 Pickering, et al. Recommendations for blood pressure measurements in humans and experimental animals, Circulation 2005, 111(5):697-716. 2New England Journal of Medicine 2008; 358: 2545-59. 3The Journal of Clinical Hypertension Vol 11 No. 10 Oct 2009 p. 542 4Am J Emerg Med 1995; 13:204-210. Copyright © 1995 by W.B. Saunders Company © 2010 Omron Healthcare, Inc. 907XLSS REV. ...

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría