Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario Toshiba, modelo TEC B-419-GS10

Fabricar: Toshiba
Tamaño del archivo: 1.69 mb
Nombre del archivo: ff696268-6d8d-4f68-b383-19b3d702c0b4.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


· Copy Firmware Files to Hard Disk The files contained on the Firmware FDK are self-decompressing files. They must be copied to the following directories of the PC hard disk before being transferred to the printer. When the “Install Program for B419” was installed onto your PC, it created the following directories: C:\Program Files\TOSHIBATEC\B419STDDL\Firmware Using Windows Explorer, copy all the files from the Firmware FDK to the above directory and decompress them into binary files (*.BIN). 2- 17 2. PRINTER SETUP EO1-33030 2.10 Program Download 2.10.3 Firmware Files Copy (Cont.) The following paragraphs will give step by step directions for running the "Install Program for B-419" on your PC which will allow you to transfer the binary files stored in directory C: \Program Files\TOSHIBATEC\ B419STDDL\Firmware to the flash memory of the B-419 printer. · Running the Install Program for B-419 1. Click on the START button to access the program menu. 2. Highlight "Programs" then highlight "TOSHIBA TEC" and click on Install Program for B-419 Series as shown in the screen display below 3. As soon as you click on Install Program for B-419, the screen will change to display the initial screen of the Install Program as shown below. 4. From the File (F) drop down menu select Open (O). 2- 18 2. PRINTER SETUP EO1-33030 2.10 Program Download 2.10.3 Firmware Files Copy (Cont.) 5. The file open screen will appear as shown in the figure below. Select the C:\Program Files\TOSHIBATEC\B419STDDL\ Firmware folder and the files in that folder will appear in the files NOTE: The C:\Program Files\ TOSHIBATEC\B419STDDL \Firmware folder is the default directory. box. 6.As soon as you highlight on the files in the files box, the right half of the screen will show all the data concerning the selected file as shown in the figure below. 7. After highlighting the desired download file in the preceding screen display, click on OPEN and the screen display shown in the figure below will appear. Confirm the COM port conditions shown at the right of the screen. 2- 19 2. PRINTER SETUP EO1-33030 2.10 Program Download 2.10.3 Firmware Files Copy (Cont.) 8. If it is necessary to change any of the communication parameters, select the Settings (S) drop down menu and then select Conditions (S) as shown in the figure below. NOTE: 1. The communications settings should be set as follows. 9. The communications setting window will appear as in figure below to allow you to change the communication parameters. Set the proper settings for Device, Parity, and Baud Rate, and click on OK button. Download: 9600 bps to 115200 bps, None parity Sensor setting: 19200 bps, None parity Printer information registration: 19200 bps, None parity Test Print: 19200 bps, None parity 2. The settings shown on the display are the default. NOTE: This procedure is only used by service personnel to download a message along with the firmware download. Be sure to select Nothing. 10. In the Settings drop down menu is another possible selection labeled Comment (C ) as shown below. If Comment (C) is selected then the comment selection menu appears. There are three different settings that can be selected in this operation, Nothing, Only Date, and Enter Some Comments. If nothing is selected no comment is attached. If Only date is selected, then the PC date will be attached as the message. If Enter Some Comments is selected, a comment message of up to 16 characters can be attached to the download, and will appear on the diagnostic printout. 2- 20 2. PRINTER SETUP EO1-33030 2.10 Program Download 2.10.3 Firmware Files Copy No comment will be sent. (Cont.) NOTE: When Nothing is selected, “(none)” will be displayed. PC date will be sent. NOTE: When Only Date is selected, the current date will be displayed. 16 character maximum message can be sent. NOTE: When Enter Some Comments is selected, a message of max. 16 characters can be entered. 11. Click the OK button to continue. · Execution of Download to Printer 1. After selecting a file for downloading in the previous steps, select the Run (R) drop down menu then select and click on START (R) as shown in the figure below. NOTE: If the file for downloading is not opened, START (R) cannot be selected. 2 -21 2. PRINTER SETUP EO1-33030 2.10 Program Download 2.10.3 Firmware Files Copy 2. After clicking on Start in the previous screen, the following message will appear on the screen. (Cont.) 3. At this time, connect the printer to the PC with the RS-232C cable. Press and hold the FEED button while sliding the printer Stand-by NOTE: switch to ON. When the printer enters DOWNLOAD mode If the message screen does not successfully, the message screen will change to the following. change, the printer failed to enter the DOWNLOAD mode. Turn on the printer power on while pressing and holding the FEED button again. 4. Press the OK button on the preceding screen to begin the sending of the Firmware file. During transmission, the following screen appears with a p...

Otros modelos de este manual:
Equipo de Taller - TEC EO1-33030 (1.69 mb)
Equipo de Taller - TEC B-419-GS10-QQ (1.69 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría