Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Toshiba, modelo TEC FDS-30

Fabricar: Toshiba
Tamaño del archivo: 2.47 mb
Nombre del archivo: 7ae4766d-85d9-4ff0-97a4-2614c0b2e2dc.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


SOUP PLU0041 $2.70 0063 13:54TM - 59 - EO-11032 ■ Changing the Whole Package Quantity (and the Price accordingly) (applicable to PLUs of Split Package Pricing type) [-► l PLU Code l [PLU1 New Whole [ST]—► New Preset [#] Package Price * Quantity max. 2 digits ; 0 to 99 > [AT/TLJ Repeatable for other PLUs. * (Repeatable from here if the PLU Code is sequential from the previous one.) ex.) To change PLU No. 61 (previously programmed three-pack with $2.50) to five-pack with $4.00 : Mode Lock to SET, 61 [PLU] 5 [STJ 400 [#] [AT/TL] to end this programming. TEC STORE 1343 PEACH DRIVE PHONES 87-6437 Thank you Can again PHONEs 87-6437 09-21-90 »111101 CHEESE PLU0061 /05 $4.00 0064 14S01TM - 60 - EO-11032 % + AND %- PRESET RATE SETTING A preset rate may be set on each of the [% + ] and [%-] key, one independent rate for each key . Once a rate is preset, the % key only will be depressed without a prior rate entry to activate the preset rate. If a rate is entered prior to the depression of the key, the entered rate (manual rate) will be activated instead. Any time outside a sale ¡mMwriwivty 1 Mode Lock : SET / GT Lock : Neutral 1 Preset % Rate I 1% + ] (For Percent Charge Preset Rate) (0.001 to 99.999(%) ; use the [. ] key if a decimal portion is contained.) I Preset % Rate I [%-] (For Percent Discount Preset Rate) ex.) To set 10% on [% + ] Key : Mode Lock to SET, enter 10, depress [% + ]. ex.) To set 5% on [%-] Key : Mode Lock to SET, enter 5, depress [%-]. TEC STORE 1343 PEACH DRIVE PHONE: 87-6437 Thank you Call again PHONE: 87-6437 09-21-90 #111101 P %+ 10% 0065 14:02TM 09-21-90 »111101 P %- 5% 0066 14S02TM To reset the rate once set: Mode Lock : SET, Enter 0, depress the required % key. (Then the % key will always require a manual rate entry in sales entries.) NOTE : When two [% +J Keys or [%-J keys are installed on keyboard, two different % rates (one for each) may be preset, in the same manner as described above. - 61 - ECM1032 LISTING CAPACITY SETTING FOR TENDER MEDIAS After Financial Daily Reset Mode Lock : SET I HALC of Each Tender Media I -► [AT/TLJ -► [CHECK TEND] -► iChg] -► [MISC] -► [CPN] “► [FSTL TEND] -► [CREDIT 1] [CREDIT 2] HALC High Amount Listing Capacity (to be set in a 2-digit code) ex.) I 3 I 4 I - ”L_ •• indicate $39.99 " equal to or smaller than $39.99. “ 4 digits — Value of the top digit NOTES : 1. To reset an individual media listing capacity, enter 0 before media key depression in the above operation. 2. The HALC of each tender media is effective only when the media key is used for tendering but not when it is used as Total key. 3. The listing capacity is cleared in “MGR” mode. It can also be cleared by the [LC OPEN] (or [OPEN]) key. ex.) To set HALCs as in the following : Table $99.99 [ATn"L] $999.99 [CHECK TEND] Kev Operation Mode Lock to SET. Enter 94, depress [AT/TL], Enter 95, depress [CHECK TEND]. - 62- E011032 PRESET RATE SETTING FOR SELECTIVE ITEMIZERS (SI1 and SI2) If any of [SI1/TL] (or [SI/TLJ) and [SI2/TL] keys are installed on the keyboard, a preset rate may be programmed on each key. As to the functions and applications of the Selective Itemizers, refer to the description on the next page. Any time outside a sale Mode Lock: SET / GT Lock: Neutral Preset S11 % Rate I [SI1/TL] (or [SI/TLJ) (0.01 to 99.99(%); use the [.] key if a decimal portion is contained.) Preset SI 2 % Rate I [SI2/TL] (On a Single-SI machine, only one Selective Itemizer Total Key is installed and labeled as “[SI/TLJ”. On a dual-SI machine, two keys, labeled as “[SI1/TL]”and “[SI2/TL]", are installed.) NOTES: 1. Whether the calculated amount by the preset SI % rate affects (i.e. add to or subtract from) the sale total is determined by a program option status selection. 2. To reset the rate once set, enter 0 as the rate. (Then the rate is regarded as 100% if the option “Non-affect” is selected. With the option “SI Affects Sale Total”, some rate other than “0” should be programmed.) ex.) To set 7% as SI1 preset % rate: Mode Lock to SET, 7 [SI1/TLJ. TEC STORE 1343 PEACH DRIVE PHONE! 87-6437 Thank you Call again PHONE: 87-6437 09-21-90 #111101 P SI1 TL IX 0072 14S09TM - 63 - EO-11032 ■ Selective Itemizer Functions and Applications The "Selective Itemizer" is a temporary total memory for each sale and is activated separately from the Main Itemizer (i.e. sale total memory). If certain Department or PLU items are programmed with the SI (selective itemizer) “net” status, the Selective Itemizer will function to add up amounts of the Sl-net-status items in registering the items, while the Main Itemizer will function to add up all the items in the sale. Thus, near the sale finalization, the operator may read the SI content by depressing the [SI/TL] key. A preset % rate may be programmed for each of SI1 and SI2 (on the previous page), and whether the calculated amount will add to, subtract fro...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría