Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Healthrider, modelo HRTL61706.0

Fabricar: Healthrider
Tamaño del archivo: 1.67 mb
Nombre del archivo: 1319f549-08f3-49e1-a0b1-6b20c9980b1c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Slide a Handrail (62) onto the post on the Left Upright (70). Finger tighten two 1 1/4" Bolts (63) into the Handrail and the post; do not fully tighten the Bolts yet. Attach the other Handrail (62) to the Right Upright (76) in the same way. 70 Post 62 62 63 63 76 6 7. Make sure that the Upright Wire (75) is positioned at the side of the post on the Right Upright (76) as shown. Set the Pulse Bar (66) on the Left and Right Uprights (70, 76). Attach the Pulse Bar with four Silver Pulse Bar Screws (64) and four Pulse Bar Star Washers (65). Start all four Silver Pulse Bar Screws before firmly tightening them. Firmly tighten the four 1 1/4" Bolts (63). 70 64 65 64 65 63 76 66 63 7 75 9 8. While a second person holds the console assembly near the Pulse Bar (66), connect the Ground Wire (107) on the Pulse Bar to the ground wire from the console assembly. Connect the wire from the console assembly to the Upright Wire (75). Make sure to connect the connectors properly (see the inset drawing). The connectors should slide together easily and snap into place. If the connectors do not slide together easily and snap into place, turn one connector and then try again. IF THE CONNECTORS ARE NOT CONNECTED PROPERLY, THE CONSOLE MAY BE DAMAGED WHEN THE POWER IS TURNED ON. Lay the wires inside the bottom of the Pulse Bar (66). 75 Console Assembly Wire 76 107 8 75 9. Set the console assembly on the Left and Right Uprights (70, 76). Be careful not to pinch any wires. Attach the console assembly to the Pulse Bar (66) with six 3/4" Screws (23). Start all six Screws, before tighten them yet. 23 Console Assembly 23 23 76 70 9 Ground Wire 66 66 10.Identify the Left Handrail Cover (68), which has a LEFT sticker on it. Slide the Left Handrail Cover onto the left Handrail (62) and up against the console assembly. Tighten two Cover Screws (52) into the Left Handrail Cover and the Left Upright (70); be careful not to overtighten the Cover Screws. Attach the Right Handrail Cover (74) in the same way. Console Assembly 52 68 70 74 52 10 62 62 10 12. See the inset drawing. Push the Uprights (70, 76) sideways so that the treadmill Frame (26) is centered between the Uprights. Firmly tighten the Upright Bolts (84, 85) on each side of the treadmill. With the help of a second person, carefully raise the Left Upright (70) and the Right Upright (76) to a vertical position 76 70, 76 26 70 26 View From Above 12 Side View 85 84 13. Make sure that all parts are properly tightened before you use the treadmill. If there are sheets of clear plastic on the treadmill decals, remove the plastic. To protect the floor or carpet, place a mat under the treadmill. Note: Extra hardware may be included. Keep the included hex key in a secure place; the large hex key is used to adjust the walking belt (see page 23). 11.Lower the Uprights (70, 76) as shown. Start the two indicated Console Screws (67) into the Left and Right Uprights (70, 76) and the console assembly. If necessary, pull back on the console assembly slightly to align the holes in the Uprights with those on the console assembly. Start the other two Console Screws before tightening all four; do not overtighten the Console Screws. Console Assembly Start First Start First 67 70 76 11 67 If you purchase the optional chest pulse sensor (see page 19), follow the steps below to install the receiver included with the chest pulse sensor. 1. Remove the key from the console and unplug the power cord. Remove the 3/4" Screw (23) and the Access Door (100) from the back of the Console Base (98). 2. Connect the wire on the receiver (A) to the indicated wire extending from the Console Base (98). Hold the receiver so the small cylinder is oriented as shown and is facing the Console Base. Attach the receiver to the plastic posts on the Access Door (100) with the two included small screws. 3. Make sure that no wires are pinched. Reattach the Access Door (100) with the 3/4" Screw (23). Discard the other wires included with the receiver. A 98 Small Cylinder23 100 Wire Small Screws 11 OPERATION AND ADJUSTMENT THE PRE-LUBRICATED WALKING BELT Your treadmill features a walking belt coated with high- performance lubricant. IMPORTANT: Never apply silicone spray or other substances to the walking belt or the walking platform. Such substances will deteriorate the walking belt and cause excessive wear. HOW TO PLUG IN THE POWER CORD DANGER: Improper connection of the equipment-grounding conductor can result in an increased risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product—if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Your treadmill, like any other type of sophisticated electronic equipment, can be seriously damaged by sudden voltage changes in your home’s power. Voltage surges, spikes, and noise interference can result from weather conditions or from other a...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría