Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Toshiba, modelo SRS-1000A

Fabricar: Toshiba
Tamaño del archivo: 167.56 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


• Source Application Entity Title TM_XA_DCM_V12 3.1.2 Real-World Activity 3.1.2.1 Real-World Activity - Transfer of X-ray Examination DICOM Recording AE acts as a FSC when chosen by the operator. This AE writes the SOP instances onto the CD-R media, creates a DICOMDIR and writes it onto the CD-R media. 3.1.3 Media Storage Application Profile DICOM Recording AE uses the Application Profile defined in Table 1. 3.1.4 Information Object Definition and DICOMDIR keys Information Object Definition and DICOMDIR keys are described in Chapter 8. 3.2 DICOM Reader Specification The DICOM Reader AE provides Conformance to the DICOM Media Storage Service, File Format Class and the Media Storage Application Profile. Table 2 Application Profile Identifier Real World Activity Role SC Option Basic Cardiac X-ray Angiographic Studies on CD-R Media STD-XABC-CD Review of X-ray Examination FSR Interchange Extended Cardiac X-ray Angiographic Studies on CD-R Media AUG-XABC-CD Review of X-ray Examination FSR Interchange 3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relevant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator. This AE reads the DICOMDIR from the CD-R media and reads the SOP instances from the CD-R media. 3.2.3 Media Storage Application Profile DICOM Reader AE uses the Application Profile defined in Table 2. 3.2.4 Information Object Definition and DICOMDIR keys Information Object Definition and DICOMDIR keys are described in Chapter 8. 4 Augmented and Private Application Profiles 4.1 Augmented Application Profiles DICOM Reader AE supports Augmented Application Profile: AUG-XABC-CD. This is a extension of the standard Application Profile: STD-XABC-CD. 4.1.1 AUG-XABC-CD 4.1.1.1 SOP Class Augmentations None 4.1.1.2 Directory Augmentations None 4.1.1.3 Other Augmentations The following attributes used within the X-ray Angiographic Image files have the specified values. Table 3 Attribute Name Tag Value Modality (0008, 0060) XA Rows (0028, 0010) 1024 Columns (0028, 0011) 1024 Bits Allocated (0028, 0100) 8 Bits Stored (0028, 0101) 8 4.2 Private Application Profiles Not applicable to this product. 5 Extensions, Specializations, and Privatizations of SOP Classes and Transfer Syntaxes Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set. Note: Settings and changes are performed by Toshiba Service Personnel at the time of installation of the Digital Fluorography System. 7 Support of Extended Character Sets This product supports the following character sets: Table 4 • ISO-IR 6 (default) Basic G0 Set 8 X-Ray Angiographic Information Object Definition 8.1 Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Table 5 Object Module / key Reference Usage1 DICOM File Meta Information 8.2.1 M Basic Directory Information Object Definition File-set Identification Module 8.3.1 M Directory Information Module 8.3.2 U Definition of Specific Directory Records PATIENT keys 8.4.1 M STUDY keys 8.4.2 M SERIES keys 8.4.3 M IMAGE keys 8.4.4 M 1 M=Mandatory, C=Conditional, U=User option 8.1.2 Media Storage XA IOD Modules Table 6 Object Module / key Reference Usage1 DICOM File Meta Information 8.2.2 M XA Information Object Definition XA IOD Modules 8.1.3 M 1 M=Mandatory, C=Conditional, U=User option 8.1.3 XA IOD Modules Table 7 Information Entity Module Reference Usage1 Patient Patient Module 8.5.1 M Study General Study Module 8.5.2 M Study Patient Study Module 8.5.3 U Series General Series Module 8.5.4 M Equipment General Equipment Module 8.5.5 M Image General Image Module 8.5.6 M Image Image Pixel Module 8.5.7 M Image Contrast/bolus Module 8.5.8 C Image Cine Module 8.5.9 C Image Multi-frame Module 8.5.10 C Image Frame Pointers Module Not Used U Image Mask Module Not Used C Image Display Shutter Module Not Used U Image Device Module Not Used U Image Therapy Module Not Used U Image X-ray Image Module 8.5.11 M Image X-ray Acquisition Module 8.5.12 M Image X-ray Collimator Module Not Used U Image X-ray Table Module Not Used C Image XA Positioner Module 8.5.13 M Image Overlay Plane Module Not Used U Image Multi-Frame Overlay Module Not Used C Image Curve Module 8.5.14 C (Note) Image Modality LUT Module Not Used C/U Image VOI LUT Module 8.5.15 U Image SOP Common Module 8.5.16 M 1 M=Mandatory, C=Conditional, U=User option Note : Always set when ECG data is available 8.2 DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Table 8 Attribute Name Tag Type Attribute Description File Preamble No Tag 1 Always set DICOM Prefix No Tag 1 Always set ("DICM") Group Length (0002, 0000) 1 Always set File Meta Information Version (0002, 0001) 1 Always set (0x0001) Media Storage SOP Class UID (0002, 0002) 1 Alw...

Otros modelos de este manual:
datos de dispositivos de procesamiento - XIDF-037A (167.56 kb)
datos de dispositivos de procesamiento - XIDF-038A (167.56 kb)
datos de dispositivos de procesamiento - DFP-2000A (167.56 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría