Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario HP, modelo HP 3PAR F200 9.6TB (16) 600Gb 15K HDD Field Starter Kit

Fabricar: HP
Tamaño del archivo: 91.99 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


This release notes document describes the modifications and known issues for Patch 05. This is a
recommended patch and is only intended to be applied to HP 3PAR OS 3.1.2.322 (MU1). Only an
authorized HP Service Provider should perform this maintenance procedure.
1.1 Supported platforms
The HP 3PAR Configuration Matrix for HP 3PAR OS 3.1.2 contains information about supported
hardware and software platforms. For a list of supported versions of each operating system, see the
Single Point of Connectivity Knowledge (SPOCK) website http://www.hp.com/storage/spock.
1.2 Verifying the patch installation
The installation of Patch 05 can be verified from an Interactive CLI session. Issue the CLI command
showversion -a -b to verify that Patch 05 is listed.
showversion -a -b
Release version 3.1.2.322
Patches: P05
Component Name Version
CLI Server 3.1.2.322 (MU1)
CLI Client 3.1.2.278
System Manager 3.1.2.428 (P05)
Kernel 3.1.2.322 (MU1)
TPD Kernel Code 3.1.2.322 (MU1)
TPD Kernel Patch 3.1.2.428 (P05)
1.3 Components
Component
Version
HP 3PAR OS
3.1.2.322 (MU1)
CLI Client
3.1.2.278
System Manager
3.1.2.428 (P05)
TPD Kernel Patch
3.1.2.428 (P05)
NOTE:
Applying this patch to the HP 3PAR OS might restart the affected OS components. With these
restarts, events and alerts might be generated and this is an expected behavior. The system continues
to serve data, but existing CLI or IMC sessions might be interrupted.
1.4 Modifications to the HP 3PAR OS
The following items are addressed in this release.
Issue ID
Item
Description
84276
Issue of false DIF error
The LSO SAS host adaptor used on an HP 3PAR StoreServ 7000 Storage
reporting is resolved.
system sometimes reports a false DIF error. To address this, the PD layer
attempts to read from the alternate path of the PD. If the PD layer can read
successfully from the alternate path, this error is counted as a false DIF error.
If large number of such errors happen in a short period of time, the primary
path of the PD fails over. If both the paths to the PD report a DIF error, then
the error is considered as a legitimate DIF error, and the drive fails in
accordance with existing handling of DIF errors.
1.1 Supported platforms
3


...

Otros modelos de este manual:
datos de dispositivos de procesamiento - HP 3PAR F200 Configuration Base (91.99 kb)
datos de dispositivos de procesamiento - HP 3PAR F200 Field Starter Kit (91.99 kb)
datos de dispositivos de procesamiento - HP 3PAR F400 9.6TB (16) 600Gb 15K HDD Field Starter Kit (91.99 kb)
datos de dispositivos de procesamiento - HP 3PAR F400 Configuration Base (91.99 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría