|
Otros manuales para este modelo:
Resumen del manual
MSA6X/7XSeries
About this document
Enclosure
This document details procedures for replacing a failed
midplane in an MSA6X Series Enclosure.
Midplane replacement
Before you begin
instructions
CAUTION: Before removing the failed component, make sure
that you have the replacement part available. Removing a
component impacts the airflow and cooling ability of the
device.
To prevent improper cooling and thermal damage, do not
For updates, visit the HP website:
operate the enclosure unless all bays are populated with either
http://www.hp.com/support/manuals.
a component or a blank.
Do not remove more than one component or blank from the
enclosure at a time. Doing so impacts the airflow and cooling
ability of the device. To avoid possible overheating, insert the
new or replacement component as quickly as possible. If the
internal temperature exceeds acceptable limits, the enclosure
may overheat and automatically shut down or restart.
Parts can be damaged by electrostatic discharge. Use proper
anti-static protection.
Verifying component failure
Before replacing the midplane, use the following methods to
verify component failure:
•
Check the following component status LEDs as identified in
the following tables:
• Hard drives—test with known good hard drives.
• I/O module—test with known good I/O module.
• Fan module—test with known good fan module.
•
Check the host log for errors.
Hard drive LED combinations
Online/activity LED Fault/UID LED
Interpretation
(green)
(amber/blue)
On, off, or flashing Alternating amber
The drive has failed, or
and blue
a predictive failure
alert has been received
for this drive; it also
has been selected by a
management
application.
© Copyright 2006 Hewlett-Packard Development Company, L.P.
On, off, or flashing Steadily blue
The drive is operating
The information contained herein is subject to change without notice.
normally, and it has
The only warranties for HP products and services are set forth in the
been selected by a
express warranty statements accompanying such products and services.
management
Nothing herein should be construed as constituting an additional
application.
warranty. HP shall not be liable for technical or editorial errors or
omissions contained herein.
On
Amber, flashing
A predictive failure
regularly (1 Hz)
alert has been received
Part number: 440585-001
for this drive.
First edition: 02/2007
Replace the drive as
soon as possible.
*440585-001*
On Off The drive is online, but
it is not currently active.
...Otros modelos de este manual:
datos de dispositivos de procesamiento - HP MSA60 Dual Domain (12) 1TB 3.5-inch DP SAS MDL HDD 12TB Bundle (490.9 kb)
datos de dispositivos de procesamiento - HP MSA60 Dual Domain (12) 450GB 3.5-inch DP SAS HDD 5.4TB Bundle (490.9 kb)
datos de dispositivos de procesamiento - HP StorageWorks MSA60 with 12 146GB SAS LFF 1.8TB Bundle (490.9 kb)
datos de dispositivos de procesamiento - HP StorageWorks MSA60 with 12 300GB SAS LFF 3.6TB Bundle (490.9 kb)