|
Otros manuales para este modelo:
Resumen del manual
Description
Affected products
The error message Blocked Temporarily, internal was shown for devices
All
on switch ports after a Power On Reset when the error message should have been
Blocked due to special (RD) zone.
After upgrading firmware to 09.09.06, CTP faults could be encountered (events
Director 2/140
410, 414, and 411), and C0 faults could occur followed by the CTP coming back
online. This only happened when an IP source was sending the switch an ICMP re-
direct packet over TCP/IP.
Events with code 411 could be posted with OSMS faults with 153C2, 153C3 and
All
153AB codes due to internal race conditions when a M-series/McDATA switch was
in a fabric with B-series switches.
While processing a GPSC command, OSMS faulted with code 73 00 00 00 while
clearing internal database.
Routes were not being set up correctly when running Frame Redirection over Fibre
All
Channel Routing, causing a host attached to the switch not to see the target.
Event 159 Frame Redirect Deactivated event messages were reported during an
All
IML (initial machine load) even when Frame Redirection was not enabled.
Error counter statistics were not maintained correctly in 4Gb QPM port cards. The
Director 2/140, Direct-
C3 Discard frames counter increased continuously even though no frame drops
or 2/64
occurred.
In a mixed M-series and B-series fabric including an Encryption Switch, when a
Director 2/140
configuration save or change on the Encryption Switch redirect zones was performed,
hosts connected the Director 2/140 lost access to their storage if also connected
to the Director 2/140, for 10 seconds or more.
A switch was blocking a PLOGI accept on the remote end because the near end
All
did not send SW_RSCN before PLOGI. This resulted in slow server bootup.
When Frame Redirection (FR) was used in a mixed M-series and B-series fabric, and
All
there were virtual targets (VT) that were either NPIV or loop devices connected to
the same physical port, and a host port was a member of two different FR zonesthat
each included a virtual target (VT1 and VT2) on the same physical port, if the con-
nection between the host and VT1 was interrupted, then the connection between
that host and VT2 might also have been interrupted.
If a port received a frame with an invalid source ID (SID), the port would not appear
Director 2/140
as a logged-in port, even though traffic was not disrupted. The Director was reporting
an incorrect port status.
In a FICON environment, the Director would provide an incorrect Interface Protocol
Director 2/140
Type for Node Selector 0 in response to the inband query Read Node Identifi-
Director 2/64
er.
Due to an internal error, some switches encountered Event 411, Firmware Fault,
All
with Fault Code 00000073.
Audit log entries showed the HAFM/EFCM server IP address as 0.0.0.0
Edge Switch 2/24
Zone activation could fail for fabrics with a large number of zones.
All
Director and Edge Switch Release Notes (09.09.09)
7
...Otros modelos de este manual:
datos de dispositivos de procesamiento - HP StorageWorks Director 2/64 base 32 port config (219.2 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/12 (219.2 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/24 (219.2 kb)
datos de dispositivos de procesamiento - HP StorageWorks Edge Switch 2/32 (219.2 kb)