Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Dimplex, modelo Purifire Electric Stove

Fabricar: Dimplex
Tamaño del archivo: 297.66 kb
Nombre del archivo: 60e226d7-e88e-4044-a9fd-cd5b2852af28.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Model Number Serial Number Model Number Label Serial Number Label Model Number Label Serial Number Label IMPORTANT INSTRUCTIONS If you have any questions about our products please have the product model and serial numbers available upon calling Dimplex customer service. To locate the model and serial number labels see below. Record the Model Number, Serial Number, and CAT number on the front cover of this manual for future reference. 2 NOTE A 15amp, 120 volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker. WARNING Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons. Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock and injury to persons. Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician. STOVE INSTALLATION 1. Make sure the units MAIN ON/OFF switch is switched OFF (refer to operating instruction section). 2. Plug the unit into a 15Amp/120volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 watts. OPERATION To access the controls, go to the back of the stove. A. MAIN POWER ON/OFF SWITCH The main on/off switch supplies power to all unit A functions (flame, purifire, heater). B B. MANUAL SELECTION SWITCH To choose between flame effect setting, flame C effect with Purifire™ setting, and flame effect with Purifire™ and heat setting. C. INTERIOR LIGHT ON/OFF SWITCH The interior light on/off switch supplies power to the interior light. D. HEATER THERMOSTAT CONTROL To adjust the temperature to your individual requirements, turn the thermostat control clockwise all the way to turn on the heater. When the room reaches the desired temperature, D turn the thermostat knob counter clockwise until you hear a click. Leave in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. RESETTING THE TEMPERATURE CUTOFF SWITCH Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the MAIN ON/OFF SWITCH to OFF and waiting 5 minutes before switching the unit back on. CAUTION If you need to continuously reset the heater, unplug the unit and call Dimplex technical support at 1-888-DIMPLEX (1-888-346-7539) Extension 4. NOTE The heater may emit a slight, harmless odor when first used. This odor is a normal condition caused by initial heating of internal heater parts and will not occur again. REMOTE CONTROL USAGE This stove is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25m), it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of 243 independent frequencies to prevent interference with other units. The frequency code is indicated on the back of the transmitter. A. Remote Control Initialization This procedure is required every time there is a loss of power to the remote control in the fireplace. (i.e. power failure, breaker tripped, main power switch is turned off) 1. Ensure that power is supplied through main service panel. 2. Locate manual controls. (refer to FIGURE 3) 3. Activate main power switch, (“ ” position) red indicator light 1 will flash. 4. Press and hold the manual selection switch for five Frequency seconds (“ ” position) UNTIL the second redCode indictor light flashes. 5. Press ON button located on the remote control transmitter (FIGURE 2). This will synchronize the remote control transmitter and receiver. B. Remote Control Usage The remote control operates the fireplace levels sequentially. The level is increased every time the FIGURE 2 ON button on the transmitter is pressed. The Main fireplace can be turned off at any point by pressing Power the OFF button on the remote control transmitter. Switch Level 1: The flame effect is turned on and the first red indicator light is activated. Level 2: The flame effect remains on, the Purifire™ Manual is activated, and the first and second red Selection Switch indicator lights are activated. Level 3: The flame effect and Purifire™ remain on, the heater is activated, and all three red Interior indicator lights are activated. Light Switch Level 1 Indicator Level 2 Indicator Level 3 Indicator FIGURE 3 FIGURE 4 MANUAL SELECTION SWITCH Operates ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría