Iniciar sesión:
Votos - 1, Puntuación media: 3 ( )

Manual de usuario Creda, modelo C150

Fabricar: Creda
Tamaño del archivo: 143.55 kb
Nombre del archivo: C150L_C150G_L153G_L153L_X153G.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Ignition does not work. Burner ports Ignitor Oven burner Grill burner If all burners fail to ignite: Check that sparks appear at the burners; a clicking noise should be heard. If not Check the battery, or fit a known good battery to the product. Batteries are not covered by the guarantee. The battery is easily changed - see the section on battery replacement. (An “AA” size alkaline battery should be used). If only one burner fails to ignite: Check that the burner is dry and that spillage of food or cleaning fluid remains are not affecting the ignitor or burner ports. Clean away any debris with a dry nylon brush such as an old toothbrush. If a wire wool pad has been used for cleaning around the burner ensure the ignitor is free from any stray strands. Any water on the burner should be dried with a cloth or kitchen towel. Burner ports Ignitor Hotplate burner. On hotplate burners make sure that all the burner parts are correctly seated on the burners. Burner ports Ignitor Installation Instructions Gas Safety (Installation & Use) Regulations Location Provision for Ventilation Prior to installation, ensure that the local distributions (nature of the gas and gas pressure) and the adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data badge which is fitted below the oven door on the plinth panel. This appliance is not designed to be connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. Particular attention should be given to the relevant requirements regarding ventilation. MODEL NUMBERS C150G, X153G, L153G Category I2H (G.B. IE) These models are set to burn NATURAL GAS (G20) at 20 mbar ONLY and cannot be used on any other gas. MODEL NUMBERS C150L, L153L Category I3+ (G.B. IE) These models are set to burn PROPANE GAS (G31) at 37 mbar and BUTANE GAS (G30) at 28 - 30 mbar and cannot be used on any other gas It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the above regulations. It is in your interest and that of safety to ensure compliance with the law. In the UK, CORGI registered installers work to safe standards of practice. The cooker must also be installed in accordance with BS 6172. Failure to install the cooker correctly could invalidate the warranty liability claims and could lead to prosecution. The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath or shower. The cooker must not be installed in a bed-sitting room of less than 20m3. L.P.G. models must not be installed in a room or internal space below ground level e.g. in a basement. The room containing the cooker should have an air supply in accordance with BS 5440: Part 2 The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require an air vent of 100cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements. Installation Instructions Technical Data Dimension Height 900mm Width 500mm Depth 600mm (excluding door handles) General Gas connection Rp 1/2 (1/2” BSP female) Pressure test point Grill injector Gas rate adjustment None Aeration adjustment None Battery 1.5V Alkaline AA Natural Gas L.P.G BURNER HEAT INPUT INJECTOR HEAT INPUT INJECTOR HOTPLATE Front left 3.0 kW 128 2.8 kW (205g/h) 82 HOTPLATE Rear left 2.0 kW 102 1.8 kW (130g/h) 65 HOTPLATE Rear right 1.0 kW 72 1.0 kW (75g/h) 50 HOTPLATE Front right 2.0 kW 102 1.8 kW (130g/h) 65 GRILL 3.8 kW 150 3.4 kW (245g/h) 95 OVEN 2.5 kW 115 2.5 kW (180g/h) 75 Installation Instructions The cooker can be close fitted below hotplate level. This requires a minimum distance of 503mm between cupboard units of hotplate height. When installing next to a tall cupboard, partition or wall, for a minimum distance of 400mm above hotplate level, allow a side clearance of at least 65mm. The diagram below illustrates the minimum clearance between the cooker and adjacent walls, cupboards etc. The wall behind the cooker 150mm below the hotplate and 450mm above, and the width of the cooker, must be a non-combustible material such as ceramic wall tiles. If the cooker is to be fitted close to a corner on the left hand side, ensure that there is a clearance of at least 50mm to allow the main oven door to open fully for when removing oven shelves. If a cooker hood is to be installed, refer to the cooker hood manufacturers’ instructions regarding fixing height. Cooker Hoods Installation Instructions Unpacking the Cooker Levelling Stability Bracket Connecting To The Gas Supply Unpack the components from inside the grill and oven: Check that the fol...

Otros modelos de este manual:
Placas - L153 (143.55 kb)
Placas - X153 (143.55 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría