Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Indesit, modelo HOB IP 751 S C UK

Fabricar: Indesit
Tamaño del archivo: 337.57 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This will ensure the safe operation and longevity of your appliance while maintaining efficient energy consumption. Connection with a rigid pipe (copper or steel) ! Connection to the gas system must be carried out in such a way as not to place any strain of any kind on the appliance. There is an adjustable L-shaped pipe fitting on the appliance supply ramp and this is fitted with a seal in order to prevent leaks. The seal must always be replaced after rotating the pipe fitting (seal provided with appliance). The gas supply pipe fitting is a threaded 1/2 gas cylindrical male attachment. Connecting a flexible jointless stainless steel pipe to a threaded attachment The gas supply pipe fitting is a threaded 1/2 gas cylindrical male attachment. These pipes must be installed so that they are never longer than 2000 mm when fully extended. Once connection has been carried out, make sure that the flexible metal pipe does not touch any moving parts and is not compressed. ! Only use pipes and seals that comply with current national regulations. Checking the tightness of the connection ! When the installation process is complete, check the pipe fittings for leaks using a soapy solution. Never use a flame. Adapting to different types of gas To adapt the hob to a different type of gas other than default type (indicated on the rating plate at the base of the hob or on the packaging), the burner nozzles should be replaced as follows: 1. Remove the hob grids and slide the burners off their seats. 2. Unscrew the nozzles using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see table 1 “Burner and nozzle characteristics”). In the case of the Mini WOK burner, use a spanner with a 7 mm opening to unscrew the nozzle (see figure). 3. Reassemble the parts following the above procedure in the reverse order. 4. Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Sticker are available from any of our Service Centres. • Adjusting the burners' primary air : Does not require adjusting. • Setting the burners to minimum: 1. Turn the tap to the low flame position. 2. Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady. 3. Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out. • f »4 III J 0 0 \ 4. Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw. 5. Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance. ! If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible. ! Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres. ! Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations). 4 Burner and nozzle specifications Table 1 Liquid Gas Natural Gas Burner Diameter (mm) Therma kW (p Nomin. l power .c.s.*) Ridot. By-Pass 1/100 (mm) Nozzle 1/100 (mm) Flc g *** )W* /h ** Nozzle 1/100 (mm) Flow* l/h Fast (R) 100 3,00 0,70 39 86 218 214 116 286 Reduced Fast (RR) 100 2,60 0,70 39 80 189 186 110 248 Semi Fast (S) 75 1,65 0.40 28 64 120 118 96 157 Auxiliary (A) 55 1,00 0,40 28 50 73 71 79 95 Mini WOK (MW) 110 3,50 1,30 57 91 254 250 138 333 Supply Pressures Nominal (mbar) Minimum (mbar) Maximum (mbar) 28-30 20 35 37 25 45 20 17 25 *** At 15°C and 1013 mbar-dry gas Propane P.C.S. = 50.37 MJ/kg. Butane P.C.S. = 49.47 MJ/kg. Natural P.C.S. = 37.78 MJ/m3 DATA PLATE Electrical connections See data plate Ci A-&\ This appliance conforms to the following European Economic Community directives: -2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments - 89/336/EEC dated 03/05/89 (Electromagnetic Compatibility) and subsequent amendments - 93/68/EEC dated 22/07/93 and subsequent amendments. - 90/336/EEC dated 29/06/90 (Gas) and subsequent amendments. - 2002/96/EC 5 Description of the appliance Overall v iew Support Grid for COOKWARE GAS BURNERS Control Knobs for GAS BURNERS Support Grid for COOKWARE GAS BURNERS Control Knobs for GAS BURNERS SAFETY DEVICES * Ignition for GAS BURNERS * GAS BURNERS differ in size and power. Use the diameter of the cookware to choose the most appropriate burner to cook with. Control Knobs for GAS BURNERS adjust the size of the flame. GAS BURNER ignition* enables a specific burner to be lit automatically. SAFETY DEVICE* st...

Otros modelos de este manual:
Placas - HOB IP 640 S UK (337.57 kb)
Placas - HOB IP 641 S C UK (337.57 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría