Iniciar sesión:
Votos - 5, Puntuación media: 4 ( )

Manual de usuario Indesit, modelo K1G21S/HU

Fabricar: Indesit
Tamaño del archivo: 960.31 kb
Nombre del archivo: 19504969000_UK-USA-AUS-HU.pdf
Idioma del manual:enhu
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


In the case of chimneys or flues Directly to the with branches (for cookers) exterior b) The room must be provided with a system for air inflow which is necessary for a regular combustion. The air flow necessary for the combustion should be at least 2 m3/h for kW of installed power. The system may be realized by drawing the air directly from outside the building through a pipe that has at least a 100 cm2 useable section and which must not be accidently obstructed (Fig. A). And further it may be realized indirectly from other adjacent rooms which are provided with a ventilation pipe for the expulsion of the fumes to the outside of the building as foresaid, and which must not be part of the building in common use or rooms with risk of fire, or bedrooms (Fig. B). Detail A Adjacent Room to room be ventilated A Fig. A Fig. B Examples of ventilation openings Increased opening between for the comburent air the door and and floor c) During prolonged use of the appliance you may consider it necessary to open a window to the outside to improve ventilation. d) The liquefied petroleum gases, which are heavier than air, stagnate towards the ground.Therefore, the rooms containing LPG cans must have openings towards the outside in order to allow the venting from the ground of eventual gas leak. Thus, the LPG cans must not be installed or settled in rooms that are below the ground level, (cellar, etc.) whether the cans are empty or partially full. It is advisable to keep in the room only the can which is being used, and it must be placed away from direct heat sources (ovens, fireplaces, stoves, etc.) that could make the can reach temperatures higher than 50°C. Levelling your appliance (only on a few models) Your cooker is supplied with feet for levelling the appliance. If necessary, these feet can be screwed into the housings in the corners of the cooker base. Mounting the legs (only on a few models) Press-fit legs are supplied which fit under the base of your cooker. Installation of the cooker The appliance can be installed next to furniture units which are no taller than the top of the cooker hob. The wall in direct contact with the back panel of the cooker must be made of non-flammable material. During operation the back panel of the cooker could reach a temperature of 50°C above room temperature. For proper installation of the cooker, the following precautions must be taken: a) The appliance can be placed in a kitchen, dining room or bedsit, but not in a bathroom. b) All furniture around the appliance must be placed at least 200 mm from the top of the cooker, should the surface of the appliance be higher than the worktop of this furniture. Curtains should not be placed behind the cooker or less than 200 mm away from the sides of the appliance. c) Any hoods must be installed according to the requirements in the installation manual for the hoods themselves. d) If the cooker is installed beneath a wall cabinet, the latter must be situated at a minimum of 420 mm above the hob. The minimum distance between the worktop and kitchen units made of combustible material is 700 mm. e) The wall in direct contact with the back panel of the cooker must be made of non-flammable materials. 4 HOOD 420Min.min. 650 mm. with hoodmin. 700 mm. without hoodmm. 600Min. mm. 420Min. mm. HOOD 420Min.min. 650 mm. with hoodmin. 700 mm. without hoodmm. 600Min. mm. 420Min. mm. Connecting the gas The appliance should be connected to the mains or to a gas cylinder in compliance with current directives. Before making the connection, check that the cooker is regulated for the gas supply you are using. If not, follow the instructions indicated in the paragraph “Adapting to different types of gas”. On some models the gas supply can be connected on the left or on the right, as necessary; to change the connection, reverse the position of the hose holder with that of the cap and replace replace the gasket (supplied with the appliance).When using liquid gas from a cylinder, install a pressure regulator which complies with current directive. Important: check that the supply pressure complies with the values indicated in table 1 “Characteristics of the burners and nozzles” since this will ensure safe operation, correct consumption and ensure a longer life to your appliance. Connection with hose Make the connection using a gas hose complying with the the characteristics provided in current directive. The internal diameter of the pipe used is as follows: - 8mm for liquid gas; - 13mm for methane gas. When installing the hose, remember to take the following precautions: • No part of the hose should touch parts whose temperature exceeds 50°C; • The length of the hose should be less than 1500 mm; • The hose should not be subject to twisting or pulling, and should not have bends or kinks. • The hose should not touch objects with sharp edges, any moving parts, and it should not be crushed; • The full length of the hose should be easy to inspect in order to check its con...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría