Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario DCS, modelo 231GR-M RU 949600674

Fabricar: DCS
Tamaño del archivo: 532.15 kb
Nombre del archivo: 887769RU.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


For unit combinations, a reinforcement beam must be used between each unit. Min. 47 mm Reinforcement beams 10 It is not necessary to attach the reinforcement beam to the work top surface, as it is held in place by a specially designed moulding, which is incorporated in the hob units flanges. The units externally measured length 145 mm: Cooker hood 290 mm: Two-zone ceramic-top electric hob Two-burner gas hob Grill Fryer Wok 580 mm: Four-zone ceramic-top electric hob Four-burner gas hob 725 mm: Four-zone ceramic-top electric hob Installation of a single unit When mounting a single unit, be it a half-or full size unit, in a worktopsurface which is thicker than 30 mm, it is necessary to make a special notch in both sides of the cutout hole, as shown in the adjacent drawing. The purpose of these notches is to create space for the electrical cables. 11 Installation The electrical connection may only be performed by a qualified electrician/ competent person. The electrical connection must be carried out in accordance with prevailing regulations for appliances using heavy current. The connection must comply with any specific requirements specified by the local electricity supply authority. There must be no interference with any of the unit’s electrical parts. The cable is mounted in the pegs as shown. Unscrew the cover while connecting the cables. A unit led directly to the power point or the outlet rose. More units may be connected via one or more junction boxes. The cable must be connected via an external switch with a contact separation of at least 3 mm in each pole. Please observe these instructions, otherwise the warranty will not cover any damage that may occur. Single-phase zero-earth Cable type 1,5 mm. HO5VV-F. The cable outside diameter must be between 7,5 and 10,5 mm. Cover 12 Mains Voltage 230 V Electrical connection 230V - 50Hz Total wattage 1500W This unit is labelled to indicate conformity with the lowvoltage directive (73/23/EEC) and the EMC directive (89/336/EEC). Unpacking Check that the hobs has no faults and hobs the nameplate. is undamaged on delivery. Write the serial number on the cover of these operating instructions to make Transport damage it easy to find in case of service. Any damage from transport which you have not carried out yourself must be reported to the retailer within one week of receipt. You will find the serial number of the 13 Service Before calling service -Technical advice Problems Redmedy Grill not working? Check earth leak circuit breaker and fuses. Fuses constantly blowing? Too many electric bulbs may be in use at the same time. 14 15 325 88-7769 Rev. 1-218 ...

Otros modelos de este manual:
Placas - 231GR-M RU 949600674 (532.15 kb)
Placas - 231GR-M RU 949600674 (532.15 kb)
Placas - 231GR-M RU 949600674 (532.15 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría