Iniciar sesión:
Votos - 3, Puntuación media: 4.7 ( )

Manual de usuario CDA, modelo RC 9000

Fabricar: CDA
Tamaño del archivo: 917.49 kb
Nombre del archivo: 59c6a4ad-b5cb-43c0-a0b2-80c0aeab7523.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Gas connection GB Cat: II 2H3+ The gas supply must use the nearest gas inlet pipe which is located at the left or the right hand side at the rear of the appliance (figs. 35, 37). The hose should also be connected in such away that it does not touch the floor. To screw the connecting tube operate with two spanners (fig. 36). The unused end inlet pipe must be closed with the plug interposing the gasket. After connecting to the mains, check that the coupling are correctly sealed, using soapy solution, but never a flame. 1/2” BSP (male) Plug Fig. 35 Fig. 36 Left gas inlet pipe Right gas inlet pipe IMPORTANT PRESCRIPTIONS FOR GAS CONNECTION Rear wall 700 mm Suggested area for gas mains connection 200 mm Fig. 37 Conversion to Natural Gas or to LPG Conversion to Natural Gas or to LPG Injectors replacement of top burners Every cooker is provided with a set of injectors for the various types of gas. Injectors not supplied can be obtained from the After-Sales Service. Select the injectors to be replaced according to the table at page 40. The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector. To replace the injectors proceed as follows: – Remove the grids and extract the burner bodies. – Using a wrench, substitute the nozzle injectors “J” (Figs. 38 - 39) with those most suitable for the kind of gas for which it is to be used (see “Table for the choice of the injectors”). The burners are constructed in such a way so as not to require the regulation of the primary air. 38 J J Fig. 38 Fig. 39 Adjusting of the minimum of the top burners Considering that in the minimum position the flame must have a length of about 4 mm and must remain lit even with a quick turn from the maximum position to that of minimum. The flame adjustment is done in the following way: – Turn on the burner – Tum the tap to the MINIMUM position – Take off the knob – With a small flat screwdriver turn the screw inside the tap rod to the correct regulation (fig. 40). Normally for LPG, tighten up the regulation screw. Fig. 40 Table for the choice of the injectors GB Cat: II 2H3+ BURNERS Nominal Reduced Power G 30 - 28-30 mbar G31 - 37 mbar G 20 20 mbar [kW] Power [kW] By-pass [1/100 mm] O injector [1/100 mm] By-pass [1/100 mm] O injector [1/100 mm] Auxiliary (A) 1,00 0,30 27 50 72 (X) Semi-rapid (SR) 1,75 0,45 32 65 table 97 (Z) Rapid (R) 3,00 0,75 42 85 adjus115 (Y) Triple-ring (TR) 3,50 1,50 65 95 135 (T) INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW) BURNERS Air necessary for combustion [m3/h] Auxiliary (A) 2,00 Semi-rapid (SR) 3,50 Rapid (R) 6,00 Triple-ring (TR) 7,00 Lubrication of the gas taps The operations must be executed by a qualified technician. IMPORTANT All intervention regarding installation maintenance and conversion of the appliance must be fulfilled with original factory parts. The manufacturer declines any liability resulting from the non-compliance of this obligation. Electrical installation Electrical installation The appliance must be connected to the electrical network verifying above all that the voltage corresponds to the value indicated on the specifications plate and that the cables section of the electrical plant can bear the load which is also indicated on the plate. The cooker can be connected directly to the mains placing an omnipolar switch with minimum opening between the contacts of 3 mm between the appliance and the mains. The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 75°C at any point. Once the cooker has been installed, the switch must always be accessible. Before effecting any intervention on the electrical parts the appliance must be disconnected from the network. Warning! Electricity can be extremely dangerous. This appliance must be earthed. Connecting feeder cable To connect the feeder cable to the cooker it is necessary to: – Remove the screw that hold shield “A” behind the cooker (fig. 41). – Insert the feeder cable of the suitable section (as described in the next chapter) into the cable clamp “D”. – Connect the phase and earth cables to the terminal block “B” according to the diagram in figure 42. – Pull the feeder cable and block it with cable clamp “D”. – Re-mount shield “A”. D B A PE .................. Fig. 41 Feeder cable section TYPE HO5RR-F 230 V PENL1 230 V 3 x 1,5 mm2 (L2) Fig. 42 Appliance servicing Appliance servicing CDA provide a quality and effective after-sales service to cover all your servicing needs. Please attach your receipt to this page for safekeeping. Please help us to help you by having the following information available when booking a service-call: 1. Model type, make and model – see the product data plate. 2. Evidence of installation / purchase date 3. Retailer where appliance was purchased 4. Clear and concise details of the fault 5. Full address including postcode and any contact phone numbers Contact telephone numbers CDA Customer Care Department • Telephone: 01949 8...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría