Iniciar sesión:
Votos - 3, Puntuación media: 5 ( )

Manual de usuario CDA, modelo HCC360

Fabricar: CDA
Tamaño del archivo: 606.21 kb
Nombre del archivo: d7e3f093-feb5-49f6-93a5-4b63a0cfdd16.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


and who will – connect the blue wire to the terminal marked with the letter comply with the l.E.E. and local regulations. N or coloured black; The wires in the mains lead are coloured in accordance with the – connect the brown wire to the terminal marked with the let- following code: ter L or coloured red. Green & Yellow = Earth Blue = Neutral . It is possible to connect the appliance directly to the mains Brown = Live. supply by means of a heavy duty switch with 3 mm minimum distance between the contacts. As the colours of the wires in the mains lead for the appliance, . The power supply cord must not touch against any hot sur-may not correspond with the coloured markings identifying the faces and must be placed so that its temperature does not terminals in your spur box, proceed as follows: exceed 75°C at any point along its length. 1) The wire which is coloured green and yellow must be con. After having installed the appliance, the power switch or nected to the terminal marked E (Earth) or coloured power plug must always be in a accessible position. Green. . The appliance must have its own supply; any other appliances 2) The wire which is coloured blue must be connected to the terinstalled near it must be supplied separately. minal marked N (Neutral), or coloured Black. – N.B. For connections to the mains power supply, never use 3) The wire which is coloured brown must be connected to the adaptors, reductions or multiple power points as these may terminal marked L (Live), or coloured Red. overheat and catch fire. In the event that installation should require modifications to the mains supply wiring system, it is recommended that a qualified technician be called to carry out substitution. The technician will also have to verify that the cross-section of the electric cables on the power point match the appliance’s power rating. Before carrying out any work on the electrical section of Connection to a good earth wiring system is absolutely the appliance, it must be disconnected from the mains. essential. The manufacturer accepts no responsibility for any inconve- If the hob surface is cracked disconnect the appliance nience caused by failure to comply with this rule. from the mains. A double pole switch must be provided no further than 2 metres from the appliance to the electrical supply. If you are using the hob for the first time, or after a period of disuse, you should set the controls to position 1 for approximately 30 seconds, to dry out any humidity. This appliance must be connected by a competent person, using fixed wiring via a DOUBLE POLE SWITCHED FUSED SPUR OUTLET. DOUBLE POLE SWITCHED FUSED SPUR OUTLET FUSE ON REPAIRS REPLACING THE POWER SUPPLY CABLE (for 2 electrical plates and vitroceramic models) Turn the cooktop over and unhook the terminal board cover by inserting a screwdriver into the two hooks “A” (fig. 8.1). Open the cable gland by unscrewing screw “F” (fig. 8.2), unscrew the terminal screws and remove the cable. The new supply cable, of suitable type and section, is connected to the terminal board following the diagram fig. 8.3. REPLACING THE POWER SUPPLY CABLE (for gas models) -The supply cable must be replaced with a cable of the same type. -The electrical cable must be connected to the terminal board following the diagrams of fig. 8.4. A Fig. 8.1 F A Fig. 8.1 F FEEDER CABLE SECTION COOKING HOB GAS type “H05V2V2-F” resistance to temperatures of 90°C 230 V~ 3 x 0,75mm2 Fig. 8.2 COOKING HOB ELECTRIC HOTPLATES The external diameter of the supply cable must not be more than 9 mm. tipo “H05RR-F” 230 V~ 3 x 1,50mm2 COOKING HOB VITROCERAMIC The external diameter of the supply cable must not be more than 9 mm. type “H05RR-F” 230 V~ 3 x 1,50mm2 230 V L1 N (L 2) PE Fig. 8.3 230 V L N Fig. 8.4 PARTE ELECTRICA88 Importante: A instalacao deve ser efetuada conforme as instrucoes do fabricante. Uma instalacao erronea pode causar danos as pessoas, animais ou coisas e defronte a tais acontecimentos o fabricante nao pode ser considerado responsavel. LIGACAO A REDE ELECTRICA . A ligacao a rede electrica deve ser feita por tecnicos qualificados e em conformidade com as normas vigentes. . Antes de mais, e necessario verificar se a tensao de rede corresponde ao valor indicado na chapa de caracteristicas do aparelho e se a seccao dos cabos da instalacao electrica tem capacidade para suportar a carga indicada na mesma chapa. . No caso do aparelho ser fornecido sem ficha, e necessario montar uma ficha normalizada, adequada a potencia absorvida pelo aparelho e conforme as normas locais vigentes. . A ficha bipolar deve ser inserida numa tomada que esteja ligada ao sistema de terra conforme as normas de seguranca. . Dado que as cores dos nucleos do cabo de alimentacao deste aparelho podem nao corresponder com as marcacoes coloridas que identificam os bornes da vossa tomada, proceder como segue: –O nucleo que e colorido de amarelo/verde deve ser coneta do ao borne da tomada marcada com a letra PE ou com o simbolo...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría