Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario Bosch, modelo ER59553EU/01

Fabricar: Bosch
Tamaño del archivo: 234.03 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:
Placas - ER59553EU/01 (281.32 kb)
Placas - ER59553EU/01 (241.53 kb)de
Placas - ER59553EU/01 (250.28 kb)es

Resumen del manual


It is important to note that we shall accept no liability for damage which is a direct or indirect result of improper connection or installation. The appliance must always be disconnected from the mains before repairs are carried out. If repairs are needed, never open the appliance yourself, but call our after-sales service. Particular care must be taken to ensure leak-proof connection! Gas connection may only be completed by an approved fitter in accordance with applicable regulations. In addition, local regulations and the requirements of the local gas supply company must also be observed. This guarantees that the regulations and the local supply company's requirements are observed. Converting the burners to another type of gas (for the fitter) Picture 5 Picture 6 Nozzles for conversion to LPG are provided with this appliance or can be obtained from the after sales service (see list included). Prior to making the necessary adjustments, the hob must be disconnected from the mains. To see which gas type has been preset in the factory; refer to the rating plate in this manual or on the underside of the hob. CHANGING THE NOZZLES The burners are adaptable to different types of gas by replacing only the nozzles for the type of gas used (see data table). To access the nozzle, simply remove the cap and flame-breaker. To change the nozzles, use a no. 7 socket wrench (picture 5). REGULATION OF MINIMUM FROM LPG TO NG Our taps are suitable for all types of gas and are regulated at the minimum as follows: 1. Light the burner and turn the knob to the minimum position. If the flame should go out, proceed as follows: a.) light the burner at maximum capacity (large flame) b.) remove the knob c.) introduce a small screwdriver in hole B on the shaft of the tap (picture 6) and unscrew the adjustment screw by two turns. d.) replace the knob and turn to the minimum position (small flame) 2. Remove the knob from the tap 3. Introduce a small screwdriver in hole B (picture 6) and tighten or loosen the adjustment screw (taking care not to turn the shaft of the tap) until the burner flame is properly adjusted at the minimum. Check that when passing quickly from the maximum position to the minimum the flame does not go out. REGULATION OF MINIMUM FROM NG TO LPG 1. Light the burner and turn the knob to the minimum position. 2. Remove the knob from the tap 3. Introduce a small screwdriver in hole B (picture 6) and tighten the adjusting screw completely (taking care not to turn the shaft of the tap). Check that when passing quickly from the maximum position to the minimum the flame does not go out. 2. OPERATION This is your new hob 1 Control knobs 2 Auxiliary burner, 1.0 kW 3 Semi - Rapid burner, 1.75 kW 4 Rapid burner, 2,7 kW 5 Triple Crown Wok burner, 3.5 kW This is your new hob 1 Control knobs 2 Auxiliary burner, 1.0 kW 3 Semi - Rapid burner, 1.75 kW 4 Rapid burner, 2,7 kW 5 Triple Crown Wok burner, 3.5 kW This control is used to make the heat setting of the Gas tap gas burner. "Small flame" = lowest setting "Large flame" = highest setting Setting procedure: The "large flame/highest flame" setting is used for initial boiling. For ongoing cooking, a variable setting between the "large flame/highest flame" and "small flame" can be made. • To reduce the flame from high to low, turn the knob anti-clockwise to the required setting. • To increase the flame, turn the knob clockwise to the required setting, with a pan on the hob. The knob for the relevant burner is first pushed Ignition down and turned anti-clockwise to "large flame". Press the knob down firmly and hold for approx. 3 seconds - only then will the gas be released from the burner and safely ignited by the sparks. When the burner is ignited release the knob. Note: if it does not light immediately: 1. check gas supply and burner position. 2. try again while holding for up to 10 seconds. If for any reason the burner flames are extinguished, switch off the control knob and wait at least 1 minute before making a new ignition attempt. If the burner still doesn’t ignite call the after sales service. The burners are turned off by means of switching Switching the the control knob to its initial position. Burners to the "Off Position" The use of a gas cooker leads to the production of Note heat and moisture in the kitchen. For this reason, make sure that the room is properly ventilated: Keep natural ventilation openings open or provide a mechanical ventilating device (e. g. an exhauster hood). Long and intensive use of the appliance may necessitate additional ventilation, e. g. opening of a window, or a more effective type of ventilation, such as a mechanical appliance operating on a higher power stage. 3. WHAT TO LOOK OUT FOR A few tips on pots Always use the correct pan for the correct burner! Do not use small pots or pans on large burners. Please see the below table for the correct pot sizes. A few tips on pots Always use the correct pan for the correct burner! Do not use small pots o...

Otros modelos de este manual:
Placas - ER59553EU/02 (234.03 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría