Iniciar sesión:
Votos - 1, Puntuación media: 4 ( )

Manual de usuario Electrolux, modelo 50 CR

Fabricar: Electrolux
Tamaño del archivo: 201.83 kb
Nombre del archivo: d58e354e-4ddf-9884-51c7-0c7e981d1ec1.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


28 L Y R I C 5 0 C R Servicing For your safety Maintenance work must only be done by a competent person. Do not try to repair the cooker yourself. This could be dangerous. It is dangerous to alter or modify the product in any way. We recommend that your cooker has an annual gas safety check carried out by our approved service organisation. Before you call a service engineer check through the 'What is Wrong and Why?' information on pages 27 and 28. If you still feel there is a problem you should contact Parkinson Cowan on 08705 929929. Your call will be routed to the Service Centre covering your postcode area. Parkinson Cowan will arrange for the cooker to be serviced. You can get service and spares from Parkinson Cowan. If you don't use manufacturers original spares the normal product approval of the cooker may not be valid. When you report a problem try to describe the nature of the fault. Always give your cookers full name and serial number which you can see inside the storage compartment. Make a note of this information in this space: Name: Serial Number: The Gas Consumers' Council The Gas Consumers' Council (GCC) is an independent organisation which protects the interests of gas users. If you need advice, you will find the telephone number in your local telephone directory under Gas. g . in . ic . rve S 29 INSTALLATION INSTRUCTIONS Serial number inside the storage compartment. Data badge on top rear of panel. For your safety Natural Gas and L.P. Gas versions of this appliance are available. Check that this model is suitable for the type of supply available. In the interest of safety this appliance must be installed and/or serviced by a competent person, as stated in the Gas Safety (Installation and Use) Regulations Current Editions. 30 L Y R I C 5 0C R TECHNICAL DATA DIMENSIONS Height Width Depth Overall 1462mm (nominal) 498mm 600mm (from elbow to front of door panel) Height to hotplate 907mm nominal see important note 'Location of the Appliance' (see Page 33). Space for fixing at hotplate level 2mm minimum 600mm clearance Nominal Space for fixing above hotplate level 100mm each side of appliance Minimum space above grill 500mm Minimum distance from rear wall 20mm Weight of appliance 50.0kg CONNECTIONS Gas Rear left hand side of appliance at hotplate level Rc. (." B.S.P. female) Electric None IGNITION Spark Generator APCO 6BG6893 Battery 1.5 volt AA size GRILL Natural Gas L.P. Gas Heat Input 3.3kW (11263 Btu/h) 3.55kW (255g/h) Injector Marking 138 95 31 L Y R I C 5 0C R HOTLATE Natural Gas R.H.F. R.H.R. L.H.R. L.H.F Heat Input 1.0kW 2.0kW 2.0kW 2.8kW (3412 Btu/h) (6824 Btu/h) (6824 Btu/h) (9554 Btu/h) Injector Marking 079 104 104 130 L. P. Gas R.H.F. R.H.R. L.H.R. L.H.F. Heat Input 1.0kW 2.0kW 2.0kW 2.7kW (71.8g/h) (143.7 g/h) (143.7 g/h) (194 g/h) Injector Marking 51 72 72 83 OVEN Natural Gas L P. Gas Heat Input 2.4kW (8189 Btu/h) 2.4kW (172.4g/h) Injector Marking 108 78 Flame Supervision Device Diamond 'H' GSD 100/28 Diamond 'H' GSD 100-30 Thermostat Diamond 'H' 1100-157/B2 Diamond 'H' 1100 155/B2 Thermostat By-pass Marking 69 78 GENERAL Ignition H.T. Spark H.T. Spark Spark Gap 3-4mm 3-4mm IMPORTANT - SAFETY REQUIREMENTS This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations Current Editions. Detailed recommendations are contained in the following British Standard Codes of Practice -BS.6172, BS.5440: Part 2 and BS.6891. All British Standards must be 'Current Editions'. PROVISION FOR VENTILATION This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with the current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation. The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2 Current Edition. All rooms require an openable window or equivalent and some rooms will require a permanent vent as well. For room volumes up to 5m. an air vent of 100cm. is required: for room volumes between 5m. and 10m. an air vent of 50cm. is required. If the room has a door that opens directly to the outside, no air vent is required. For room volumes that exceed 11m. no air vent is required. If there are other fuel burning appliances in the same room, BS.5440: Part 2 Current Edition should be consulted to determine the requisite air vent requirements. Prolonged intensive use of the appliance may call for additional ventilation, for example opening a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present. 32 L Y R I C 5 0C R LOCATION OF APPLIANCE This appliance must not be installed in a bed-sitting room of volume less than 20m. or in a bathroom or shower room. It is essential that the appliance is positioned as stated below. The appliance must be a minimum of 20mm from the rear wall (note that this dimension is provided by the inlet elbow). Shelves, wall cabi...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría