Fabricar: Humminbird
Tamaño del archivo: 11.68 mb
Nombre del archivo: 778cHDManual.pdf
|
Resumen del manual
The available Lower Range settings are determined by your Humminbird® model as follows: • 778c HD: Auto to 1500 ft, Auto to 500 m (International Models only); Default = Auto • 778c HD XD: Auto to 3200 ft, Auto to 975 m (International Models only); Default = Auto Flasher X-Press™ Menu 56 Zoom Level (Circular Flasher View, Ice Fishing Mode only) Settings: 1x, 2x; Default = 1x Zoom Level sets the magnification level for the Circular Flasher View when Ice Fishing Mode is turned on. When the Zoom Level is set to 1x, the Zoom feature is turned off. When the Zoom Level is set to 2x, the Circular Flasher View displays a 2x magnified view of the area you choose. The zoomed view is shown on the right side of the flasher dial between two lines. The normal view is shown on the left side of the flasher dial. The Zoom Range can be adjusted with the RIGHT and LEFT Cursor key. See Views: Circular Flasher View for more information. Color Palette (Circular Flasher View, Ice Fishing Mode only) Settings: Palette 1, Palette 2, Palette 3; Default = Palette 3 Color Palette sets the colors used to display sonar returns in the Circular Flasher View when Ice Fishing Mode is turned on. The active color palette is shown in the center of the circular flasher display. The color palettes range from weak to strong sonar return signals, which are displayed left to right on the color preview bar. See Views: Circular Flasher View for more information. Choose from the following color palettes: Palette 1: Green (weak), Yellow (medium), Red (strong) Palette 2: Yellow (weak), Green (medium), Red (strong) Palette 3: Blue (weakest), Green (weak), Light Green (weak to medium), Yellow (medium), Orange (fairly strong), Red (strong) 57 Flasher X-Press™ Menu Alarms Menu Tab From any view, press the MENU key twice to access the Main Menu. The Alarms tab will be the default selection. NOTE: When an alarm is triggered, you can silence it by pressing any key. The alarm will be silenced and will not be triggered again until a new instance of the alarm condition is detected. NOTE: Menu options can be expanded or simplified by setting the User Mode to Advanced or Normal. See Main Menu: User Mode for details. Alarms Menu Alarms Menu Tab 58 DepthAlarmSettings:Off,1to100ft,or0.5to30m(InternationalModelsonly);Default=OffDepthAlarmSettings:Off,1to100ft,or0.5to30m(InternationalModelsonly);Default=Off Depth Alarm sounds when the depth becomes equal to or less than the menu setting. Fish ID Alarm Settings: Off, All, Large/Medium, Large; Default = Off Fish ID Alarm sounds when the Fishfinder detects fish that correspond to the alarm setting. Fish ID Alarm will only sound if Fish ID+™ is on. Forexample,ifyou'vesettheFishIDAlarmtosoundforLargefishonly,theFishIDalarmwillsoundwhenalarge-sizedfishisdetected. Off All Large/Medium Large Low Battery Alarm Settings: Off, 8.5V to 13.5V; Default = Off Low Battery Alarm sounds when the input battery voltage is equal to or less than the menu setting. The battery alarm will only sound for the battery that is connected to the Fishfinder. The Low Battery Alarm should be set to warn you when the battery voltage drops below the safety margin that you have determined. Forinstance,ifyouarerunningatrollingmotor(batteryoperated),youwouldwanttosettheLowBatteryAlarmtosoundbeforethebatteryvoltagedropstoolowforittobeusedtostartyourmain,gasoline-poweredengine. 59 Alarms Menu Tab Temp.AlarmSettings:Off,33to120Fahrenheit,0to50Celsius(InternationalModelsonly);Default=OffTemp.AlarmSettings:Off,33to120Fahrenheit,0to50Celsius(InternationalModelsonly);Default=Off Temp. Alarm sounds when the water temperature detected by the Fishfinder reaches the Temp. Alarm setting, which is either set in degrees Fahrenheit or Celsius [International Models only]. Forexample,iftheTemp.Alarmissetto58degreesFahrenheit,andthewatertemperaturefallsfrom60degreesto58degrees,theTemp.Alarmwillsound. Similarly,ifthewatertemperaturerisesfrom56degreesto58degrees,theTemp.Alarmwillalsosound. AlarmToneSettings:High,Medium,Low;Default=Medium Alarm Tone selects the pitch of the alarm sound. A brief tone will be produced as you adjust the Alarm Tone so that you can select the tone that you can hear best. Timer Setup Settings: Press the RIGHT Cursor key to open the dialog box. Timer Setup allows you to open a dialog box to create settings for the Timer. You can also start the countdown from this dialog box. When the Timer is started, the clock counts down from the amount of time set in the dialog box. • Time: Use the 4-WAY Cursor Control key to set the hours, minutes, and seconds. • Save and Start: To start the Timer immediately, select Save and Start, and press the RIGHT Cursor key. Alarms Menu Tab 60 • Save and Close: To save your settings and start the Timer at a later time, select Save and Close, and press the RIGHT Cursor key. Also, see Start Timer. • Digital Readout: To display the Timer on-screen as it counts down, see Views: To Change the Digital Readouts. Start Timer Settings: ...